配置型号包含以下特性:
Oscilloscope Probes10MHz <= 100MHz特性 | 参数 |
---|---|
High Frequency (range) | 10MHz <= 100MHz |
A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability.
The THDP0200 and P5205A are active differential probes that are capable of safely measuring differential voltages up to ±1500 V. The probes are effective in making measurements in IGBT circuits such as motor drives and power converters.
Key Features |
Bandwidths up to 200 MHz |
Up to 6000 V differential (DC + pk AC) |
Up to 2300 V common (RMS) |
Overrange Indicator |
Safety Certified |
Switchable Attenuation |
Switchable bandwidth limit |
Benefits | |
Applications | Floating measurements Switching power supply design Motor drive design Electronic ballast design CRT display design Power converter design and service Power device evaluation |
Connectivity | BNC interface (P5200A probes) TekVPI® interface (TMDP and THDP Series probes) TekProbe® interface (P5202A, P5205A, and P5210A Series probes) |
Specifications | ||||
High-voltage Differential Probes | ||||
Model Overview | ||||
Model | P5200A | P5202A | P5205A | P5210A |
Attenuation | 50X / 500X | 20X / 200X | 50X / 500X | 100X / 1000X |
Differential Voltage | 500X: ±1300 V 50X: ±130 V | 200X: ±640 V 20X: ±64 V | 500X: ±1300 V 50X: ±130 V | 1000X: ±5600 V 100X: ±560 V |
Common Mode Voltage | ±1300 V | ±640 V | ±1300 V | ±5600 V |
Maximum Input Voltage-to-Earth | 1000 V CAT II | 450 V CAT l 300 V CAT ll | 1000 V CAT II | 2300 V CAT l 1000 V CAT III |
Bandwidth | 50 MHz | 100 MHz | 100 MHz | 50 MHz |
Differential Input Impedance | 10 MΩ || 2 pF | 5 MΩ || 2 pF | 10 MΩ || 2 pF | 40 MΩ || 2.5 pF |
Input Impedance between each Input and Ground | 5 MΩ || 4 pF | 2.5 MΩ || 4 pF | 5 MΩ || 4 pF | 20 MΩ || 5 pF |
Typical CMRR | DC: >80 dB 100 kHz: >60 dB 3.2 MHz: >30 dB 50 MHz: >26 dB | DC: >80 dB 100 kHz: >60 dB 3.2 MHz: >40 dB 50 MHz: >30 dB | DC: >80 dB 100 kHz: >60 dB 3.2 MHz: >40 dB 50 MHz: >30 dB | DC: >80 dB 100 kHz: >60 dB 3.2 MHz: >40 dB 50 MHz: >30 dB |
Cable Length | 1.8 m | 1.8 m | 1.8 m | 1.8 m |
Specifications | ||||
High Voltage Differential Probes | ||||
Model Overview | ||||
Model | Attenuation | Bandwidth | Input Impedance | Maximum Voltage |
P5200A | 50X / 500X | 50 MHz | 10 MΩ || 2 pF | 500X: ± 1300 V 50X: ± 130 V |
P5202A | 20X / 200X | 100 MHz | 5 MΩ || 2 pF | 200X: ± 640 V 20X: ± 64 V |
P5205A | 50X / 500X | 100 MHz | 10 MΩ || 2 pF | 500X: ± 1300 V 50X: ± 130 V |
THDP0200 | 50X / 500X | 200 MHz | 10 MΩ || 2 pF | 500X: ± 1500 V 50X: ± 150 V |
TMDP0200 | 25X / 250X | 200 MHz | 5 MΩ || 2 pF | 250X: ± 750 V 25X: ± 75 V |
P5210A | 100X / 1000X | 50 MHz | 40 MΩ || 2.5 pF | 1000X: ± 5600 V 100X: ± 560 V |
THDP0100 | 100X / 1000X | 100 MHz | 40 MΩ || 2.5 pF | 1000X: ± 6000 V 100X: ± 600 V |
TDP0500 | 5X / 50X | 500 MHz | 1 MΩ || ≤ 1 pF | 50X: ± 42 V 5X: ± 4.2 V |
TDP1000 | 5X / 50X | 1 GHz | 1 MΩ || ≤ 1 pF | 50X: ± 42 V 5X: ± 4.2 V |
P6251 | 5X / 50X | 1 GHz | 1 MΩ || ≤ 1 pF | 50X: ± 42 V 5X: ± 4.2 V |