A high voltage differential probe is used for measuring the voltage difference between two test points where neither test point is at ground. High voltage differential probes from Tektronix can be used for signals up to 6000 V. These probes are the best choice for making non-ground referenced, floating or isolated measurements in large part due to their common mode rejection capability.
The TMDP0200 is designed for medium-voltage applications with differential requirements up to ±750 V. These probes have lower attenuation ranges and offer better signal-to-noise ratio.
The TMDP Series probes are equipped with the TekVPI® interface which allows smart communication between the oscilloscope and probe. Pushing the probe menu button will launch the probe control menu on the oscilloscope display providing access to all relevant probe settings and controls. These probes are designed to operate on TekVPI® oscilloscopes without requiring the TPA-BNC adapter.
Key Features |
Bandwidths up to 200 MHz |
Up to 6000 V differential (DC + pk AC) |
Up to 2300 V common (RMS) |
Overrange Indicator |
Safety Certified |
Switchable Attenuation |
Switchable bandwidth limit |
Benefits |
|
Applications | Floating measurements
Switching power supply design
Motor drive design
Electronic ballast design
CRT display design
Power converter design and service
Power device evaluation
|
Connectivity | BNC interface (P5200A probes)
TekVPI® interface (TMDP and THDP Series probes)
TekProbe® interface (P5202A, P5205A, and P5210A Series probes)
|
Specifications |
|
|
|
High-voltage Differential Probes |
|
|
|
Model Overview |
|
|
|
Model | TMDP0200 | THDP0200 | THDP0100 |
Attenuation | 25X / 250X | 50X / 500X | 100X / 1000X |
Differential Voltage
(Typical)
| 250X: ±750 V
25X: ±75 V
| 500X: ±1500 V
50X: ±150 V
| 1000X: ±6000 V
100X: ±600 V
|
Common Mode Voltage
(Typical)
| ±750 V | ±1500 V | ±6000 V |
Maximum Input Voltage-to-Earth
(Typical)
| 450 V CAT I
300 V CAT III
| 1000 V CAT II
600 V CAT III
| 2300 V CAT I
1000 V CAT III
|
Bandwidth
(Typical)
| 200 MHz | 200 MHz | 100 MHz |
Rise Time | <2 ns | <2 ns | <3.6 ns |
Slew Rate
(Typical)
| <275 V/ns at 1/250 gain | <650 V/ns at 1/500 gain | <2500 V/ns at 1/1000 gain |
Input Impedance at the Probe Tip
(Typical)
| 5 MΩ || <2 pF | 10 MΩ || <2 pF | 40 MΩ || <2.5 pF |
Typical CMRR
(Typical)
| DC: > -80 dB
100 kHz: > -60 dB
3.2 MHz: > -30 dB
100 MHz: > -26 dB
| DC: > -80 dB
100 kHz: > -60 dB
3.2 MHz: > -30 dB
100 MHz: > -26 dB
| DC: > -80 dB
100 kHz: > -60 dB
3.2 MHz: > -30 dB
100 MHz: > -26 dB
|
Cable Length
(Typical)
| 1.5 m | 1.5 m | 1.5 m |
DC Gain Accuracy | ±2% | ±2% | ±2% |
Specifications |
|
|
|
|
High Voltage Differential Probes |
|
|
|
|
Model Overview |
|
|
|
|
Model | Attenuation | Bandwidth | Input Impedance | Maximum Voltage |
P5200A | 50X / 500X | 50 MHz | 10 MΩ || 2 pF | 500X: ± 1300 V
50X: ± 130 V
|
P5202A | 20X / 200X | 100 MHz | 5 MΩ || 2 pF | 200X: ± 640 V
20X: ± 64 V
|
P5205A | 50X / 500X | 100 MHz | 10 MΩ || 2 pF | 500X: ± 1300 V
50X: ± 130 V
|
THDP0200 | 50X / 500X | 200 MHz | 10 MΩ || 2 pF | 500X: ± 1500 V
50X: ± 150 V
|
TMDP0200 | 25X / 250X | 200 MHz | 5 MΩ || 2 pF | 250X: ± 750 V
25X: ± 75 V
|
P5210A | 100X / 1000X | 50 MHz | 40 MΩ || 2.5 pF | 1000X: ± 5600 V
100X: ± 560 V
|
THDP0100 | 100X / 1000X | 100 MHz | 40 MΩ || 2.5 pF | 1000X: ± 6000 V
100X: ± 600 V
|
TDP0500 | 5X / 50X | 500 MHz | 1 MΩ || ≤ 1 pF | 50X: ± 42 V
5X: ± 4.2 V
|
TDP1000 | 5X / 50X | 1 GHz | 1 MΩ || ≤ 1 pF | 50X: ± 42 V
5X: ± 4.2 V
|
P6251 | 5X / 50X | 1 GHz | 1 MΩ || ≤ 1 pF | 50X: ± 42 V
5X: ± 4.2 V
|