配置型號包含以下特性:
Electrical & Power QualityLow Resistance Meters請參考資源中的資料文檔或查看產品總覽。
如果您想瞭解更多,請 聯繫,我們的團隊將為您提供幫助。
The MEGGER DLRO10 bring new standards to low resistance measurement. A fully automatic instrument, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges.
The DLRO10 is built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, they are small enough to be taken into areas which were previously too small to access. DLRO10 uses a large, bright 4-1/2-digit LED display.
Key Features |
Accurate results in under three seconds |
Auto current reversal cancels standing emfs |
Fuse protected to 600 V |
NiMH battery reduces weight |
250 mW power limit (with optional override) to avoid heating the test sample |
Automatically detects continuity in potential and current connections |
Visible warning of high voltages present at the terminals |
Visible warning of current flowing in the test sample |
Multiple operating modes including fully automatic |
Specifications | |
DLRO 10 and DLRO 10X Digital Microhmmeter | |
Features | Parameters |
Measurement Mode | DLRO 10: Manual, Auto, Continuous, Inductive DLRO 10X: Manual, Auto, Continuous, Inductive, Undirectional |
Measurement Control | DLRO 10: Fully Automatic DLRO 10X: Fully Automatic/Manual |
Measurement Speed | <3s for forward and reverse current and to display average |
Display | Measurement: 4½ digit seven segment LED |
Range and Safety | DLRO10: LED indications DLRO10X: Large backlight LCD |
Test Method | Single cycle reversing d.c. ratiometric measurement - average result display |
Test Current Accuracy | ±10% |
Test Current Stability | <10 ppm per second |
Lead Resistance | Maximum 100 mΩ total for 10 A Operation irrespective of battery condition. |
Voltmeter Input Impedance | >200 kΩ |
Noise Rejection | Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level. |
Data Transfer | DLRO10X: Real Time or from storage via RS232 |
Data Storage | DLRO10X: 700 tests |
Memo Field | DLRO10X: Up to 200 characters per test via integral alphanumeric keypad |
Battery Type | 7Ah NiMH rechargeable |
Battery Life | Typical 1000 x 10 A tests before recharge |
Battery Charge Time | Via external 90 V - 260 V 50/60 Hz charger from 12 to 15 V dc supply Standard: 2.5 hours to 90% capacity, 4 hours to fully charged Slow Charge: +10 °C to + 45 °C (50 °F to 113 °F) |
Operating Temperature Range and Humidity | +5 °C to +45 °C (41 °F to 113 °F) at full accuracy -10 °C to +50 °C (14 °F to 122 °F) at reduced accuracy <90% RH @ 40 °C (104 °F) non-condensing |
Storage Temperature Range and Humidity | -30 °C to +70 °C (50 °F to 113 °F) <90% RH @ 40 °C (104 °F) non-condensing |
Temperature Co-Efficient | <0.01% per °C, over range 5 °C to 40 °C (<0.0006% per °F from 41 °F to 104 °F) |
Maximum Altitude | 2000m (6562 ft) to full safety specifications |
Safety | In accordance with IEC61010-1 CAT III 600 V - only when DH6 leads are used. |
EMC | IP65 case closed IP54 battery operation |
Dimensions | 220 x 100 x 237 mm |
Weight | 2,6 kg including battery |
Notes:
The accuracy stated assumes forward and reverse measurements.
Inductive mode or undirectional mode will introduce an undefined error if an external EMF is present.
Specifications | |
DLRO 10 and DLRO 10X Digital Microhmmeter | |
Model Overview | |
Model / Part Number | Description |
1006-660 | DLRO10 + NO LEADSET SUPPLIED = DLRO10-NLS, |
1006-598 | DLRO10 + LEADSET SUPPLIED = DLRO10 + DH4-C, |
1006-659 | DLRO10X + NO LEADSET SUPPLIED = DLRO10X-NLS, |
1006-600 | DLRO10X + LEADSET SUPPLIED = DLRO10X + DH4-C, |
Included Accessories | |
6121-492 | 7 Ah NiMH battery module. |
1006-444 | DH4-C Duplex handspikes (2) One with indicator lights. 1.5m (Not NLS models) |
6280-333 | Battery charger for operation from 115/230 V, 50/60Hz supply |
6280-332 | Cigar lighter adapter for battery charging |
6172-473 | User guide |
6170-618 | Warranty card |
Optional Accessories | |
-- | Connect Test Lead Options Please see Resources – see data sheet DLROTestLeads_DS_en_V01 |
-- | Standard Test Lead Option Please see Resources – see data sheet DLRO_TL_DS_en_V01 |
6380-138 | Carrying case for DLRO10/10X and all standard accessories. |
18313 | Carrying bag for cables |
249000 | Calibration Shunt,10 Ω, current rating 1 mA |
249001 | Calibration Shunt, 1 Ω, current rating 10 mA |
249002 | Calibration Shunt, 100 mΩ current rating 1A |
249003 | Calibration Shunt, 10 mΩ current rating 10 A |
CERT-NIST | Certificate of Calibration for Shunts, NIST |
1003-172 | DLRO10LPU-EU Mains power attachment (schuko plug) |
1003-093 | DLRO10LPU-UK Mains power attachment (UK plug) |
1003-171 | DLRO10LPU-US Mains power attachment (US plug) |
Replacement Tips for; DH4, DH5 and DH6 Handspikes | |
25940-012 | Needle point |
25940-014 | Serrated end |