Configured models contain the following attributes:
Power Supplies / Electronic LoadsDC Power Supplies <50VPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
The EX354D and EX354T provide high levels of power (up to 305 watts) in a compact and attractive case style. High resolution controls allow precise setting of voltage and current levels which are indicated on accurate and legible digital meters. Excellent line and load regulation are matched by low noise and good transient response. High power efficiency ensures that the unit remains cool without any fan noise.
The EX354D has two independent and isolated outputs each with a 0 to 35V, 0 to 4A capability. The outputs operate in constant voltage or constant current mode with automatic cross-over and mode indication. Each output has its own on-off switch. Where higher voltages or currents are required the outputs can be wired in either series or parallel to provide voltages up to 70 volts or currents up to 8 Amps.
The EX series incorporates separate digital voltage and current meters on each main output. The meters use bright 14mm (0·56”) LED displays and have an update rate of 4 per second providing near instantaneous response. Simultaneous metering of voltage and current provides accurate information “at a glance” and avoids any possibility of misinterpretation. When an output switch is set to “off”, the current limit setting is displayed enabling conditions to be set before the load is connected. With the right-hand main output off, the right-hand meters can be used to momentarily display the preset Auxiliary voltage and current limit.
To reflect the increasing usage of low-voltage logic devices, the third output of the EX354T can be switched between 5V and 3.3V.
The EX series has been designed to meet the stringent requirements of relevant IEC standards for safety and EMC, including harmonics emissions. All outputs are intrinsically short circuit proof, and are protected against external voltages and reverse currents.
Key Features |
Dual isolated outputs of 0 to 35V at 0 to 4A each |
Separate digital voltage and current meters for each output |
Constant voltage or constant current operation |
Compact and light weight design with low heat output |
Specifications | |||
EX Series DC Power Supply | |||
Model Overview | |||
Model | EX354TV | EX354D | EX354T |
Voltage Range | 0V to 35V minimum | 0V to 35V minimum | 0V to 35V minimum |
Current Range | 0A to 4A minimum | 0A to 4A minimum | 0A to 4A minimum |
Operating Mode | Constant voltage or constant current with automatic cross-over | Constant voltage or constant current with automatic cross-over | Constant voltage or constant current with automatic cross-over |
Load Regulation | <0.01% of maximum output for 90% load change | <0.01% of maximum output for 90% load change | <0.01% of maximum output for 90% load change |
Line Regulation | <0.01% of maximum output for 10% line change | <0.01% of maximum output for 10% line change | <0.01% of maximum output for 10% line change |
Output Impedance | Typically <5mΩ in constant voltage mode. Typically >50kΩ in constant current mode | Typically <5mΩ in constant voltage mode. Typically >50kΩ in constant current mode | Typically <5mΩ in constant voltage mode. Typically >20kΩ in constant current mode |
Output Protection: | Output will withstand up to 40V forward voltage | Outputs will withstand forward voltages up to 40V | Outputs will withstand forward voltages up to 40V |
Output Terminals | Universal 4mm safety binding posts on 19mm (0.75”) pitch | Universal 4mm safety binding posts on 19mm (0.75”) pitch | 4mm terminals on 19mm (0.75") pitch |
Ripple & Noise (20MHz bandwidth) | Typically <2mVrms, <10mVpk-pk (CV mode) | Typically <2mVrms, <10mVpk-pk (CV mode) | Typically <2mV rms, <10mV pk-pk, (CV mode) |
Voltage Setting | By coarse and fine controls | By coarse and fine controls | By coarse and fine controls |
Current Setting | By single logarithmic control | By single logarithmic control | By single logarithmic control |
AC Input | 110V - 240V AC ± 10%, 50/60Hz. Installation Category II | 110V - 240V AC ± 10%, 50/60Hz. Installation Category II | 110V - 240V AC ± 10%, 50/60Hz. Installation Category II |
Power Consumption | 500VA max | 500VA max | 500VA max |
Operating Range | +5ºC to +40ºC, 20% to 80% RH | +5ºC to +40ºC, 20% to 80% RH | +5ºC to +40ºC, 20% to 80% RH |
Storage Range | −40ºC to + 70ºC | −40ºC to + 70ºC | −40ºC to + 70ºC |
Environmental | Indoor use at altitudes up to 2000m, Pollution Degree 2 | Indoor use at altitudes up to 2000m, Pollution Degree 2 | Indoor use at altitudes up to 2000m, Pollution Degree 2 |
Safety | Complies with EN61010-1. EMC: Complies with EN61326 | Complies with EN61010-1. EMC: Complies with EN61326 | Complies with EN61010-1. EMC: Complies with EN61326 |
Weight | 4.3 kg | 4.3 kg | 4.3 kg |