Los modelos configurados tienen las siguientes opciones:
RF & Microwave Spectrum AnalyzersSpectrum Analyzers-Performance20GHz <= 50GHzDC <= 1kHzBenchtopUtilice "Presupuesto Rápido" y nos pondremos en contacto con usted y le cotizaremos para su necesidad exacta.
También puede ponerse en contacto, si lo prefiere, y nuestros expertos podrán orientarlo con la aplicación y la solución de adquisición adecuadas para este producto.
Atributo | Valor |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
Low Frequency (range) | DC <= 1kHz |
Form Factor | Benchtop |
The N9042B Signal Analyzer sets a new level of performance for high frequency measurements. Frequency options up to 50 GHz cover the current 5GNR FR1 and FR2 bands, as well as most radar, EW, and satellite bands.
Analysis bandwidth can be configured to 1 GHz; 1.5 GHz, 2 GHz, 4 GHz; and even up to 11 GHz bandwidth using an external digitizer.
A completely new front end provides low noise performance and high-dynamic range, addressing applications in Tx test, such as EVM and other modulation quality tests – while also excelling at measurements of low-level and unknown signals.
Key Features |
Ensure your designs meet the latest standards with ready-to-use measurement applications and signal analysis software |
See signals clearly with an unbanded, preselected sweep from 2 Hz to 110 GHz and 11 GHz of analysis bandwidth |
Test the true performance of your 5G NR transmitter with the industry's best error vector magnitude (EVM) |
Find out-of-band emissions or spurs quickly in your radar designs with the industry's best swept displayed average noise level (DANL) |
Develop high-throughput satellite communication designs with 4 GHz of corrected analysis bandwidth |
Specifications | |
N9042B UXA X-Series Signal Analyzer | |
Features | Parameters |
Temperature Range | Operating: 0 to 40 °C Altitude: 4,600 m (approx. 15,000 feet) Maximum Relative Humidity: 95% non-condensing |
Power Requirements | Voltage and Frequency (nominal): 100/120V, 50/60/400Hz 220/240V, 50/60Hz Rated Output Power: 850W Note: The instruments can operate with mains supply voltage fluctuations up to ± 10% of the nominal voltage |
Display | Resolution: 1280 x 800 Size: 357 mm (14.1 in.) diagonal (nominal) capacitive multi-touch screen |
Data Storage | Internal: Removable solid-state drive (≥ 256 GB) External: Supports USB 3.0/2.0 compatible memory devices |
Weight (without options) | Net: 38.6 kg (nominal) Shipping: 53.9 kg (119 lbs) (nominal) |
Dimensions | Height: 281 mm (11 in) Width: 459 mm (18 in) Length: 575 mm (22.6) |
CPU | Modular, upgradeable; Intel i7, 6-core, 1.9 GHz clock, 8 GB DDR4 DRAM; includes secure memory for instrument cal data |
SSD (Solid-State Drive) | 256 GB, removeable |
Operating System | Windows-10, Enterprise |
Specifications | ||
N9042B UXA X-Series Signal Analyzer | ||
Model Overview | ||
Model / Option Number | Description | Additional Information |
Frequency Range | ||
N9042B-526 | Frequency range, 2 Hz to 26.5 GHz | - |
N9042B-544 | Frequency range, 2 Hz to 44 GHz | - |
N9042B-550 | Frequency range, 2 Hz to 50 GHz | - |
Analysis Bandwidth | ||
N9042B-R10 | Analysis Bandwidth, 1 GHz | - |
N9042B-R15 | Analysis Bandwidth, 1.5 GHz | - |
N9042B-R20 | Analysis Bandwidth, 2 GHz | - |
N9042B-R40 | Analysis Bandwidth, 4 GHz | - |
Analysis Bandwidth, 11 GHz | See N9042B-CRW in Select Connection Options | |
Attenuator | ||
Standard | Mechanical attenuator | 2 dB steps, 0 to 70 dB; licensed as N9042B-FSA |
N9040B-EA3 | Electronic attenuator up to 3.6 GHz | Add in addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB |
Performance Options | ||
Standard | Digital processor with 4 GB capture memory | Licensed as N9042B-DP4 |
Standard | Enhanced phase noise performance | DDS-based LO assembly; licensed as N9042B-EP0 |
Standard | External mixing | Provides external mixing with Keysight and third-party mixers; single port 1 for LO out and IF in (SMA female); licensed as N9042B-EXM |
Standard | Fast sweep capability | Improves sweep speed at swept mode; licensed as N9042B-FS1 and FS2 |
Standard | LO/IM nulling | Minimizes the LO feed-thru and the intermodulation distortion; licensed as N9042B-NUL |
Standard | Low noise path | Improves sensitivity (DANL) in frequency bands above 3.6 GHz without degrading dynamic range; licensed as N9042B-LNP |
Standard | Microwave preselector bypass | Bypass the microwave preselector for wider bandwidth IF; licensed as N9042B-MPB |
Standard | Full bypass path | Bypass the microwave preselector and enable the low noise path for improved sensitivity above 3.6 GHz; standard in instruments when Option R10, R15, R20 or R40 is installed; licensed as N9042B-FBP |
Standard | Precision frequency reference | Aging rate: ± 1 x 10-7/year; licensed as N9042B-PFR |
Standard | Noise floor extension | Improves analyzer’s DANL performance; licensed as N9042B-NF2 |
Standard | Enhanced display package | Includes spectrogram, trace zoom, and zone span in SA mode; licensed as N90E1EDPB |
Standard | Fast power, up to maximum available analysis bandwidth | Accelerate power measurements such as ACPR; licensed as N90E1FP2B |
Preamplifier | ||
N9042B-P26 | Preamplifier, 26.5 GHz | Compatible with N9042B-526 only |
N9042B-P44 | Preamplifier, 44 GHz | Compatible with N9042B-544 only |
N9042B-P4L | Preamplifier, 44 GHz, basic | Compatible with N9042B-544 only; non-IVL, no export control |
N9042B-P50 | Preamplifier, 50 GHz | Compatible with N9042B-550 only |
N9042B-P5L | Preamplifier, 50 GHz, basic | Compatible with N9042B-550 only: non-IVL, no export control |
Standard | Low noise amplifier | Licensed as N9042B-LNA |
PC Security | ||
N9042B-SF1 | Security features, exclude launching programs | Prevents the launching of Windows programs from the instrument application |
N9042B-SF2 | Security features, prohibit saving results | Prevents instrument application from saving/recall of measurement results or user configurations to/from instrument’s data storage |
N9042B-SS1 | Additional removable solidstate drive, Win10 | Provides a fully-imaged, removable SSD in addition to the one installed in instruments, with Windows 10 operating system |
Source Connectivity | ||
N9042B-ESC | External source control | External source control for selected Keysight EXG, MXG, and PSG signal generators; supports external mixing; includes 3 BNC cables and 1 cross-over LAN cable |
Connection Options | ||
N9042B-ALV | Auxiliary log video output | Fast rise time video out; output on Aux IF connector |
N9042B-YAV | Y-axis video output | Screen video (0-1 volt open circuit); log video and linear video |
N9042B-CRP | Connector rear, programmable IF output | IF out 10 to 75 MHz (in 500 kHz steps); output on Aux IF connector at rear panel |
N9042B-CRW | Connector, IF out, wide | Enables front panel Wide IF Out connector that provides 11 GHz BW IF signal from the internal wideband signal paths. Is required for N9042BEDC, External Digitizer Control |
The V3050A Frequency Extender can be combined with the N9042B, to extend the maximum frequency up to 110 GHz. The V3050A features a low-noise design for outstanding sensitivity; a preselector filterbank to eliminate image responses; fundamental mixing for high dynamic range; and a “remote head” form-factor that interfaces seamlessly to the N9042B. The N9042B supports the X-series family of multi-touch applications, as well as the 89600 VSA software. A new CPU performs compute-intensive measurements, such as demodulation and EVM, up to 40% faster than prior analyzers.
V3050A Frequency Extender Option | |
Option | Frequency Range |
F06 | 50 GHz to 67 GHz |
F09 | 50 GHz to 90 GHz* |
F11 | 50 GHz to 110 GHz** |
Notes:
* Opt ion F09 conforms to limit ations governing export to restricted countries (does not require IVL ). When used for w ide-bandwidth analysis (IQ), the highest allowed frequency (at center of bandwidth) is reduced by ½ of the maximum bandw idth that is configured (optional licenses) for a given instrument. For example, with option R20 licensed (2 GHz analy sis bandwidth), the maximum center frequency allowed is 89 GHz.
** I VL required for export to restricted countries