Specifications |
|
SGX Series
Programmable Precision High Power DC Power Supply
|
|
Feature | Parameter |
Input |
|
Nominal Voltage
(3 phase, 3 wire + ground)
| 208/230VAC (operating range 187 - 253VAC)
380/400VAC (operating range 342 - 440VAC)
440/480VAC (operating range 396 - 528VAC)
|
Frequency | 47 – 63Hz, 400Hz
(400Hz @ 208VAC, for 6U units is optional modification and does not carry CE, UL or CSA markings)
|
Power Factor
(at full rated load; 50/60Hz)
| 0.90, typical, for all AC input ratings.
Power factor is not solely determined by power supply input characteristics, but is dependent on the level of DC output power and interaction with the source impedance of AC mains.
|
Protection
(typical)
| ½ cycle ride-though, typical,on all three phases, 3 cycle ride through on single phase; missing phase shutdown
(800V model 6.4 msec on all 3 phases)
|
Physical |
|
Width | 3U Models (10V - 30V): 19.00 in (48.3 cm)
3U Models (40V - 1000V): 19.00 in (48.3 cm)
6U Models (60V - 600V): 19.00 in (48.3 cm)
|
Depth | 3U Models (10V - 30V): 28.0 in (71.1 cm)
3U Models (40V - 1000V): 26.3 in (66.8 cm)
6U Models (60V - 600V): 27.1 in (68.8 cm)
|
Height | 3U Models (10V - 30V): 5.25 in (13.3 cm)
3U Models (40V - 1000V): 5.25 in (13.3 cm)
6U Models (60V - 600V): 10.5 in (26.7 cm)
|
Weight | 3U Models (10V - 30V):
(4kW, 10V 15V) ≈<65 lbs (29 kg)
(5kW, 20V 30V) ≈<65 lbs (29 kg)
(8kW, 10V 15V) ≈<85 lbs (39 kg)
(10kW, 20V 30V) ≈<85 lbs (39 kg)
(12kW, 10V 15V) ≈<110 lbs (50kg)
(15kW, 20V 30V) ≈<110 lbs (50kg)
3U Models (40V - 1000V):
(5kW) ≈ ≤60 lbs (27 kg)
(10kW) ≈ ≤75 lbs (34 kg)
(15kW) ≈≤90 lbs (41 kg)
6U Models (60V - 600V):
(20kW) ≈ ≤140 lbs (64 kg)
(25kW) ≈ ≤155 lbs (71 kg)
(30kW) ≈≤170 lbs (78 kg)
|
Environmental |
|
Operating Temperature | 0 to 50ºC |
Storage Temperature | -25º C to 65º C |
Humidity Range | Relative humidity up to 95% non-condensing, 0º C – 50º C |
Altitude | Operating full power available up to 5,000ft.
(~1,500m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
|
Cooling | Front and side airinlet,rear exhaust.
Temperature controlled, variable speed fans.
Units may be stacked without spacing.
|
Regulatory | Certified to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, Semi-F47 Compliant.
LVD Categories: Installation Category II: Pollution Degree 2; Class II Equipment: for Indoor Use Only, back panel not user accessible.
EMC Directive, EN 61326:1998
|