The N1040A is a dual electrical channel plug-in module for the N1000A DCA-X mainframe and provides two electrical channels with maximum bandwidth of 33 or 60 GHz, based on the option selected.
Key Features |
Bandwidth to 60 GHz, jitter as low as 90 fs |
Flexible: choose 33 GHz or 60 GHz maximum bandwidth |
Low cost of test: up to 8 channels per mainframe, provides high throughput |
Protect your investment: works with both the N1000A (250 kSa/s sampling rate) and 86100D (40 kSa/s sampling rate) mainframes |
Specifications |
|
N1040A
Dual Electrical Channel Module
|
|
Feature | Parameter |
Applications | NRZ
PAM4
|
Bandwidth | 60 GHz |
Channels | 2 electrical |
Input Type | 1.85 mm (#060), 2.92 mm (#033) |
Instrument Type | Equivalent-Time |
Max Memory Depth | n/a |
Max Sample Rate | Up to 250 KHz |
Module Type | Electrical |
Operating System | Windows 10 |
Supported Filter Range | 10 GHz to 70 GHz |
Type | Equivalent-Time |
Specifications |
|
DCA-X Modules |
|
Model Overview |
|
Model | Description |
N1000A | Infiniium DCA-X mainframe |
Optical Electrical Modules * |
|
N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
Dual/ Quad Electrical Channel Modules * |
|
N1040A | Dual electrical channel module |
N1045B | 2/4 port 60 GHz electrical remote head |
N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
TDR/TDT Modules * |
|
N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
Precision Waveform Analyzer Module * |
|
N1060A | Precision waveform analyzer ² (6) |
External Clock Recovery Solutions Module * |
|
N1076B | Electrical clock recovery |
N1077A | Optical/electrical clock recovery |
N1077B | Optical/electrical clock recovery |
N1078A | Optical/electrical clock recovery |
DCA-M Sampling Oscilloscope Module * |
|
N1090A | Optical sampling oscilloscope |
Optical DCA-M Sampling Oscilloscope Module * |
|
N1092A/B/D | Single optical channel oscilloscope |
N1092B | Dual optical channel oscilloscope |
N1092D | Quad optical channel oscilloscope |
N1092C | Single optical, dual electrical channel oscilloscope |
N1092E | Dual optical, dual electrical channel oscilloscope |
Electrical DCA-M Oscilloscope Module * |
|
N1094A | Dual electrical channel oscilloscope |
N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .