Configured models contain the following attributes:
Oscilloscopes & Logic AnalyzersSampling Oscilloscopes50GHz <= 85GHzPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Attribute | Value |
---|---|
High Frequency (range) | 50GHz <= 85GHz |
A three-slot wide DCA-X module that integrated two 50/85 GHz electrical channels with a clock recovery (CDR) and a precision timebase (PTB) to provide residual jitter as low as 45 fs for more accurate jitter measurements.
The Keysight N1060A precision waveform analyzer is a digital communications analyzer (DCA) module that is compatible with the Keysight N1000A mainframe. Like all of Keysight's DCA modules, the N1060A provides a wide range of configurations and performance options to interchange the bandwidth and clock recovery data rate of your oscilloscope solution.
Key Features |
Gain margin with high instrument performance: bandwidth to > 90 GHz, residual jitter as low as 45 fs, adjustable clock recovery peaking and loop bandwidth |
Reduce validation time with analysis tools like jitter spectrum analysis and software clock recovery emulation |
Reduce development time through instrument flexibility |
Enjoy simple, one connection “triggerless” operation with integrated clock recovery data rates to 64 GBd (112 Gb/s) (NRZ and PAM4) and integrated pickoffs |
Specifications | |
N1060A Precision Waveform Analyzer | |
Features | Parameters |
Applications | NRZ PAM4 |
Bandwidth | > 90 GHz |
Channels | 2 electrical with CRU & PTB |
Input Type | 1.0 mm |
Max Memory Depth | n/a |
Max Sample Rate | Up to 250 KHz |
Module Type | Electrical |
Operating System | Windows 10 |
Supported Filter Range | 16.5 GHz to 100 GHz |
Type | Equivalent-Time |
Specifications | |
DCA-X Modules | |
Model Overview | |
Model | Description |
N1000A | Infiniium DCA-X mainframe |
86100D | Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe |
Optical Electrical Modules * | |
N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
Dual/ Quad Electrical Channel Modules * | |
N1040A | Dual electrical channel module |
N1045B | 2/4 port 60 GHz electrical remote head |
N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
TDR/TDT Modules * | |
N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
Precision Waveform Analyzer Module * | |
N1060A | Precision waveform analyzer ² (6) |
External Clock Recovery Solutions Module * | |
N1076B | Electrical clock recovery |
N1077A | Optical/electrical clock recovery |
N1077B | Optical/electrical clock recovery |
N1078A | Optical/electrical clock recovery |
DCA-M Sampling Oscilloscope Module * | |
N1090A | Optical sampling oscilloscope |
Optical DCA-M Sampling Oscilloscope Module * | |
N1092A/B/D | Single optical channel oscilloscope |
N1092B | Dual optical channel oscilloscope |
N1092D | Quad optical channel oscilloscope |
N1092C | Single optical, dual electrical channel oscilloscope |
N1092E | Dual optical, dual electrical channel oscilloscope |
Electrical DCA-M Oscilloscope Module * | |
N1094A | Dual electrical channel oscilloscope |
N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .
Specifications | |
Precision Waveform Analyzer Modules | |
Model Overview | |
Model | Description |
N1060A-050¹ | Dual 50 GHz electrical channels |
N1060A-085¹ | Dual 85 GHz electrical channels |
N1060A-216 | Clock recovery 125 MBd to 16 GBd |
N1060A-232 | Clock recovery 125 MBd to 32 GBd |
N1060A-264 | Clock recovery 125 MBd to 64 GBd |
N1060A-PTB | Integrated precision timebase (mandatory option²) |
N1060A-E33 | Integrated hardware filters for 33 GHz, 40 GHz, and 43 GHz |
N1060A-EVA | Integrated variable equalizers in clock path (mandatory option²) |
N1060A-JSA | Jitter Spectrum Analysis (mandatory option²) |
N1060A-A1F | Two 1 mm (f) to 1 mm (f) adapters |
N1060A-A1M | Two 1 mm (m) to 1 mm (m) adapters |
N1060A-A1X | Two 1 mm (m) to 1 mm (f) adapters |
N1060A-CA1 | Cable pair, 1 mm (m) to 1 mm (f), 160 mm length |
N1060A-CA2 | Matched cable pair, 2.4 mm (m) to 2.4 mm (m), 24 inch length |
N1060A-DC2 | Two DC blocks, 2.4 mm connectors, 16V, 50 kHz to 50 GHz |
N1060AU-085 | Upgrade to Option 085 Performance |
N1060AU-264 | Upgrade to Option 264 |
N1060AU-232 | Upgrade to Option 232 |
Note:
¹ 86100D option ETR recommended when used in an 86100D mainframe, N1000A option PLK recommended when used in an N1000A mainframe
² Mandatory options are automatically provided with the product and cannot be unselected.