配置型号包含以下特性:
RF & MicrowaveRF Power Sensors20GHz <= 50GHz特性 | 参数 |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
Keysight U2020 X-series USB power sensors provides the peak and average power measurement capability of a power meter in a compact and portable form factor.
The Keysight U2020 X-series USB peak and average power sensors come bundled with the N1918A Power Analysis Manager software at no additional cost. Simply connect the sensor to your PC to perform complex pulse analysis and standard average power measurement.
The U2020 X-Series is also supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming.
Key Features |
Frequency range of 50 MHz to 40 GHz |
Wide dynamic range of -30 to +20 dBm (peak/gated), -45 dBm to 20 dBm (average only mode) |
30 MHz video bandwidth and single shot real-time capture at 80 Msample/sec per second |
Internal zeroing & calibration |
High measurement speed of up to 25,000 readings/second (free run/fast buffer mode) |
A BenchVue software license (BV0007B) is now included with your instrument. |
BenchVue makes it simple to connect, control instruments, and automate test sequences. |
Benefits | |
Perform measurements direct from your PC | The U2020 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform complex pulse analysis and standard average power measurement. |
Built in external trigger in and out | External trigger will enable accurate trigger of small signals close to the signal noise floor. With the built-in trigger in/out connection on the Keysight U2020 X-series USB power sensors; you can connect an external trigger signal from a signal source or the device under test directly to the USB sensor through a standard BNC to SMB cable. |
Specifications | ||
U2020 X-Series | ||
Model Overview | ||
Model | U2021XA | U2022XA |
Frequency Range | 50 MHz to 18 GHz | 50 MHz to 40 GHz 50 MHz to 50 GHz (with Option H50) |
Power Range (Normal Mode) | –30 dBm to 20 dBm (50 MHz to <500 MHz) –35 dBm to 20 dBm (500 MHz to 40 GHz) –35 dBm to 8 dBm (> 40 GHz to 50 GHz) | –30 dBm to 20 dBm (50 MHz to <500 MHz) –35 dBm to 20 dBm (500 MHz to 40 GHz) –35 dBm to 8 dBm (> 40 GHz to 50 GHz) |
Power Range (Average Only Mode (1)(2)) | –45 dBm to 20 dBm (50 MHz to 40 GHz) –45 dBm to 8 dBm (> 40 GHz to 50 GHz) | –45 dBm to 20 dBm (50 MHz to 40 GHz) –45 dBm to 8 dBm (> 40 GHz to 50 GHz) |
Damage Level | 23 dBm (average power) 30 dBm (< 1 μs duration) (peak power) | 23 dBm (average power) 30 dBm (< 1 μs duration) (peak power) |
Rise/Fall Time | ≤ 13 ns (3) | ≤ 13 ns (3) |
Maximum Sampling Rate | 80 Msamples/sec, continuous sampling | 80 Msamples/sec, continuous sampling |
Video Bandwidth | ≥ 30 MHz | ≥ 30 MHz |
Single-Shot Bandwidth | ≥ 30 MHz | ≥ 30 MHz |
Minimum Pulse Width | 50 ns (4) | 50 ns (4) |
Basic Accuracy of Average Power Measurement (5) | ≤ ± 0.2 dB or ± 4.5% | ≤ ± 0.3 dB or ± 6.7% |
Maximum Capture Length | 1 s (decimated) 1.2 ms (at full sampling rate) | 1 s (decimated) 1.2 ms (at full sampling rate) |
Maximum Pulse Repetition Rate | 10 MHz (based on 8 samples/period) | 10 MHz (based on 8 samples/period) |
Connector Type | N-type (m) | 2.4 mm (m) |
Specifications | |
U2020 X-Series USB Peak and Average Power Sensors | |
Model Overview | |
Model | Description |
U2021XA | X-Series USB peak and average power sensor, 50 MHz to 18 GHz Included Accessories: Power sensor cable 5 ft (1.5 m), default cable length BNC male to SMB female trigger cable, 50 Ω, 1.5 m (Quantity: 2) Certificate of calibration |
U2022XA | X-Series USB peak and average power sensor, 50 MHz to 40 GHz Included Accessories: Power sensor cable 5 ft (1.5 m), default cable length BNC male to SMB female trigger cable, 50 Ω, 1.5 m (Quantity: 2) Certificate of calibration |
U2022XA-H50 | X-Series USB peak and average power sensor, 50 MHz to 50 GHz Included Accessories: Power sensor cable 5 ft (1.5 m), default cable length BNC male to SMB female trigger cable, 50 Ω, 1.5 m (Quantity: 2) Certificate of calibration |