配置型号包含以下特性:
Oscilloscopes & Logic AnalyzersSampling Oscilloscopes20GHz <= 50GHz特性 | 参数 |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
A fully-integrated TDR/TDT/S-parameter measurement system.
New digital designs make signal integrity more challenging. That's why the Keysight N1055A remote head module is designed to provide fast and accurate impedance and S-parameter measurements on high-speed designs with up to 16 ports. Configure your DCA-X oscilloscope mainframe with one to four N1055A time-domain reflectometry (TDR) / time-domain transmission (TDT) modules for an economical solution.
Key Features |
Bandwidth options: 35 or 50 GHz (upgradable) |
Edge speed (10-90%, typical): 18 ps (35 GHz) or 7 ps (50 GHz) |
Channel options: 2 or 4 per module (upgradable) with independent skew control and up to 16 channels per 86100D mainframe |
Ultra-thin remote head: 1.6 m phase-stable cable, 2.92 mm (35 GHz) or 1.85 mm (50 GHz) connectors, and integrated 67 GHz diode limiters for ESD/EOS protection |
TDR fixture de-embedding removes effects of fixtures, cables or probes connected between remote heads and DUT |
Specifications | |
N1055A Remote Sampling Head Module | |
Feature | Parameter |
Applications | NRZ PAM4 |
Bandwidth | 50 GHz |
Channels | 2/4 electrical remote head with TDR/TDT |
Input Type | 1.85 mm (#5xF/5xM), 2.92 mm (#3xF/3xM) |
Instrument Type | Equivalent-Time |
Max Memory Depth | n/a |
Max Sample Rate | Up to 250 KHz |
Module Type | Electrical with TDR/TDT |
Operating System | Windows 10 |
Supported Filter Range | n/a |
Type | Equivalent-Time |
Specifications | |
DCA-X Modules | |
Model Overview | |
Model | Description |
N1000A | Infiniium DCA-X mainframe |
Optical Electrical Modules * | |
N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
Dual/ Quad Electrical Channel Modules * | |
N1040A | Dual electrical channel module |
N1045B | 2/4 port 60 GHz electrical remote head |
N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
TDR/TDT Modules * | |
N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
Precision Waveform Analyzer Module * | |
N1060A | Precision waveform analyzer ² (6) |
External Clock Recovery Solutions Module * | |
N1076B | Electrical clock recovery |
N1077A | Optical/electrical clock recovery |
N1077B | Optical/electrical clock recovery |
N1078A | Optical/electrical clock recovery |
DCA-M Sampling Oscilloscope Module * | |
N1090A | Optical sampling oscilloscope |
Optical DCA-M Sampling Oscilloscope Module * | |
N1092A/B/D | Single optical channel oscilloscope |
N1092B | Dual optical channel oscilloscope |
N1092D | Quad optical channel oscilloscope |
N1092C | Single optical, dual electrical channel oscilloscope |
N1092E | Dual optical, dual electrical channel oscilloscope |
Electrical DCA-M Oscilloscope Module * | |
N1094A | Dual electrical channel oscilloscope |
N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .