配置型号包含以下特性:
Oscilloscopes & Logic AnalyzersSampling Oscilloscopes50GHz <= 85GHz特性 | 参数 |
---|---|
High Frequency (range) | 50GHz <= 85GHz |
The N1045B 60 GHz remote sampling head module is engineered to provide superior measurement accuracy with the highest throughput for testing multi-lane electrical designs.
The Keysight N1045B electrical port sampling head is a digital communications analyzer (DCA) module that is compatible with the N1000A DCA-X mainframe. Keysight's DCA modules provide a wide range of configurations and performance options to interchange the bandwidth, channel count, and features of your oscilloscope solution.
Key Features |
60 GHz bandwidth (65 GHz typical) |
2 or 4 channels per module (user-selectable option) |
User-selectable bandwidth settings of 20 / 35 / 45 / 60 GHz |
Electrical inputs: 1.85 mm male or female (user-selectable option), sample rate 250 kSa/s |
Specifications | |
N1045B Electrical Remote Sampling Head Module | |
Feature | Parameter |
Applications | NRZ PAM4 |
Bandwidth | 60 GHz |
Channels | 2/4 electrical remote head |
Input Type | 1.85 mm |
Instrument Type | Equivalent-Time |
Max Memory Depth | n/a |
Max Sample Rate | Up to 250 KHz |
Module Type | Electrical |
Operating System | Windows 10 |
Supported Filter Range | 10 GHz to 70 GHz |
Type: | Equivalent-Time |
Specifications | |
DCA-X Modules | |
Model Overview | |
Model | Description |
N1000A | Infiniium DCA-X mainframe |
86100D | Infiniium DCA-X Wide-Bandwidth Oscilloscope Mainframe |
Optical Electrical Modules * | |
N1030A | Single 65 GHz optical channel, 9/125 μm fiber input |
N1030B | Two 65 GHz optical channels, 9/125 μm fiber input |
N1032A | Single 120 GHz optical channel, 9/125 μm fiber input |
N1032B | Two 120 GHz optical channels, 9/125 μm fiber input |
Dual/ Quad Electrical Channel Modules * | |
N1040A | Dual electrical channel module |
N1045B | 2/4 port 60 GHz electrical remote head |
N1046A | 100 GHz, 1/2/4 port electrical remote sampling head |
TDR/TDT Modules * | |
N1055A ¹ | 35/50 GHz 2/4 Port electrical remote head module with TDR/TDT |
Precision Waveform Analyzer Module * | |
N1060A | Precision waveform analyzer ² (6) |
External Clock Recovery Solutions Module * | |
N1076B | Electrical clock recovery |
N1077A | Optical/electrical clock recovery |
N1077B | Optical/electrical clock recovery |
N1078A | Optical/electrical clock recovery |
DCA-M Sampling Oscilloscope Module * | |
N1090A | Optical sampling oscilloscope |
Optical DCA-M Sampling Oscilloscope Module * | |
N1092A/B/D | Single optical channel oscilloscope |
N1092B | Dual optical channel oscilloscope |
N1092D | Quad optical channel oscilloscope |
N1092C | Single optical, dual electrical channel oscilloscope |
N1092E | Dual optical, dual electrical channel oscilloscope |
Electrical DCA-M Oscilloscope Module * | |
N1094A | Dual electrical channel oscilloscope |
N1094B | Quad electrical channel oscilloscope |
Note:
* Please See Data Sheet in Resources for module options
¹ When used in an 86100D, 86100D option ETR is recommended if more than one TDR module is connected to the same DUT
² Module includes a custom System Impulse Response Correction (SIRC) file for each channel .