Kenmerk | Waarde |
---|---|
High Frequency (range) | 100kHz <= 1MHz |
The LCX LCR meters are versatile, extremely accurate and perform measurements quickly. They are ideal for challenging applications in research, development and production. Two instrument models and various options cover applications with a test signal frequency of up to 10 MHz. Internal and external bias functions, comprehensive analysis options and versatile test fixtures expand the wide range of possible applications.
The LCX200 has an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed.
Key Features |
Frequency range upgradeable to 10 MHz |
Basic accuracy of ±0.05 % for impedance measurements |
Basic accuracy of ±0.03° for phase measurements |
DC bias up to 40 V |
Data logging function |
Benefits | |
Selectable Frequency Range | All LCX models measure under DC conditions. The AC range already begins at 4Hz. The upper frequency limit on the LCX100 is 300kHz. In its base configuration, the LCX200 is designed for a maximum frequency of 500kHz; this frequency limit can, however, be extended to 1MHz or 10MHz. This means that the ideal instrument is available for any given application and budget. |
Fast, Accurate and Versatile | Both LCX models combine high measurement speed, accuracy and versatile measurement capabilities. This makes them ideal for standard measurements in development, for material analysis in research as well as for fast production testing. With their broad measurement ranges, they also cover applications with extremely low and extremely high impedances. Three measurement times are available: Fast: ≤ 15ms Medium: ≤ 100ms Slow: ≤ 500ms The basic accuracy for impedance measurements is ±0.05%. and for phase measurements ±0.03° |
Test Signals for all Requirements | Test signals can be generated from 100mV to 10V and deliver a current of up to 200mA. The instruments have a selectable output impedance of 100Ω or 10Ω. The actual current flow and the voltage applied and measured using the monitor function. |
DC Bias | In many applications an adjustable DC bias is needed to measure C and L components at different operation points. The LCX100 and LCX200 generate a DC bias voltage of up to 10V. As an option, it is also possible to set a DC bias current (up to 200mA). DC bias voltages of up to 40V can be applied at an external connection on the rear panel (LCX-K108 option) using a standard DC power supply for example an NGA. |
Data Logging Function | Th LCX LCR meters provide a fast logging function for recording all measured values. The data can be saved on an external USB flash drive or transferred to an external PC via USB or LAN. With a data rate of up to 10 sample/s, the measured values are available every 100ms. |
Specifications | ||
LCX LCR Meter | ||
Model Overview | ||
Model | LCX100 | LCX200 |
Test Signal Frequency | DC, 4 Hz to 300 kHz | DC, 4 Hz to 10 MHz (option) |
Test Signal Voltage | 100 mV to 10 V | < 1 MHz: 100 mV to 10 V > 1 MHz: 100 mV to 2 V |
DC bias Voltage (internal) | 0 V to +10 V | 0 V to +10 V |
DC bias Current (internal) | 0 mA to 200 mA | 0 mA to 200 mA |
External DC bias Voltage, Input | 0 V to +40 V | 0 V to +40 V |
Source Impedance | 100 Ω, 10 Ω | 100 Ω, 10 Ω |
Measurement Range | 100 mΩ to 100 MΩ | 100 mΩ to 100 MΩ |
Basic Accuracy for Impedance Measurements | 0.05 % | 0.05 % |
Specifications | ||||||
LCX LCR Meter | ||||||
Model Overview | ||||||
Model | Order Number | Measurement Functions | Frequency Range | Test Signal Voltage (RMS) | Test Signal Current | Internal bias Voltage |
LCX100 | 3629.8856.02 | Cp, Cs, Lp, Ls, D, Q, G, Rp, Rs, Rdc, R, X, Z, Y, Θd, Θr, B, M, N | DC, 4 Hz to 300 kHz | 100 mV to 10 V | 1 mA to 200 mA | 0 V - 10 V |
LCX200 | 3629.8856.03 | Cp, Cs, Lp, Ls, D, Q, G, Rp, Rs, Rdc, R, X, Z, Y, Θd, Θr, B, M, N | DC, 4 Hz to 500 kHz (1 MHz or 10 MHz optional) | ≤ 1 MHz: 100 mV to 10 V ≤ 5 MHz: 100 mV to 2 V > 5 MHz: 100 mV to 1 V | ≤ 1 MHz: 1 mA to 100 mA > 1 MHz to ≤ 5 MHz: 1 mA to 20 mA > 5 MHz: 1 mA to 10 mA | 0 V - 10 V |
Specifications | ||
LCX LCR Meter | ||
Model Overview | ||
Model | Order Number | Description |
Base Unit | ||
LCX100 | 3629.8856.02 | LCR meter, 300 kHz |
LCX200 | 3629.8856.03 | LCR meter, 500 kHz |
Options | ||
LCX-K106 | 3630.1922.03 | Advanced analysis functions |
LCX-K107 | 3660.7741.03 | Digital I/O ports and binning function |
LCX-K108 | 3692.9791.03 | Extended bias functions |
LCX-K201 | 3630.1880.03 | Frequency upgrade to 1 MHz, for R&S®LCX200 |
LCX-K210 | 3630.1900.03 | Frequency upgrade to 10 MHz, for R&S®LCX200 |
NG-B105 | 5601.6000.02 | IEEE-488 (GPIB) interface, for R&S®NGP/LCX |
Test Fixtures | ||
LCX-Z1 | 3639.2296.02 | Test fixture for axial/radial lead type devices |
LCX-Z2 | 3638.6446.02 | Kelvin clip lead |
LCX-Z3 | 3639.2509.02 | Test fixture for SMD components |
LCX-Z4 | 3639.2515.02 | Test tweezers for SMD components |
LCX-Z5 | 3639.2521.02 | Transformer test cables |
LCX-Z11 | 3639.2538.02 | BNC extension, length: 1 m |
System Components | ||
ZZA-GE23 | 5601.4059.02 | 19" rack adapter, 2 HU |