Configured models contain the following attributes:
Telecommunication Transmission TestersTelcom TestPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
The VIAVI Multiple Application Platform (MAP-200) is an optical test and measurement platform optimized for cost-effective development and manufacturing of optical transmission network elements.
Today’s rapidly changing optical market requires investment in productivity-enhancing technologies and tools, making the MAP-200 scalable test platform the right tool needed in even the most stringent environments. Based on its previous generation, the MAP-200 builds on the differentiation of offering the broadest portfolio of modules in the densest and most configurable platform. The MAP-200 is optimized for test applications in lab and manufacturing environments ranging from insertion loss testing to dispersion penalty testing.
The MAP-200 mainframe comes in three configurations for optimal test set adaptability: a three-slot configuration and a 19-inch rack, eight-slot configuration oriented as either front- or rear-facing for optimal fiber routing. All three configurations are 3 RU high. The MAP-200 mainframes include hardware required for bench-top use, including rubber feet for optimal stability and vibration isolation. Furthermore, the MAP-200 saves costs because users can share modules within a mainframe.
Benefits |
Available in three mainframe configurations |
GPIB- and LXI-compliant (Ethernet) |
Optional 10.4-inch touch-screen-display module with integrated keypad and scroll wheel |
DVI port for external display |
USB-device ports for external keyboard and mouse |
Modules can be safely hot-swapped |
Field-replaceable controller/powersupply module |
Compatible with current MAP modules |
Applications |
Enables transceiver and transponder testing |
Permits comprehensive passive and active component, laser, and amplifier testing |
Facilitates 10 G and 40 G system and subsystem testing |
Specifications | |||
Multiple Application Platform | |||
Series Overview | |||
Mainframe | MAP-230 | MAP-280 | MAP-280R |
Capacity | 3 modules | 8 modules | 8 modules |
Controller | |||
CPU | Power PC architecture | Power PC architecture | Power PC architecture |
Operating System | System Linux | System Linux | System Linux |
Internal Storage | 200 MB user flash storage | 200 MB user flash storage | 200 MB user flash storage |
Interfaces | |||
Remote Interface | USB, GPIB, Ethernet 10/100/1000Base-T | USB, GPIB, Ethernet 10/100/1000Base-T | USB, GPIB, Ethernet 10/100/1000Base-T |
USB Device Compatibility | Mouse, keyboard, memory stick | Mouse, keyboard, memory stick | Mouse, keyboard, memory stick |
Display External | MAP-200KD (optional) or standard DVI monitor | MAP-200KD (optional) or standard DVI monitor | MAP-200KD (optional) or standard DVI monitor |
Ports | |||
USB Host Ports | 2 rear and 2 front | 2 rear and 2 front | 2 rear and 2 front |
USB Device Ports | 1 front | 1 front | 1 front |
LAN | 1 rear | 1 rear | 1 rear |
GPIB | 1 rear | 1 rear | 1 rear |
DVI Video | 1 rear | 1 rear | 1 rear |
LXI triggers | 25-pin Micro-D connectors | 25-pin Micro-D connectors | 25-pin Micro-D connectors |
Automation | |||
Driver Type | IVI-compliant | IVI-compliant | IVI-compliant |
Driver Compatibility | LabVIEW, LabWindows, Visual C++, Visual Basic | LabVIEW, LabWindows, Visual C++, Visual Basic | LabVIEW, LabWindows, Visual C++, Visual Basic |
Accessibility | Multi-user sharing support | Multi-user sharing support | Multi-user sharing support |
Electric and Safety | |||
Power (1) | 100 to 200 V AC, 50/60 Hz, Auto-switching (field-replaceable as part of the power supply controller module) | 100 to 200 V AC, 50/60 Hz, Auto-switching (field-replaceable as part of the power supply controller module) | 100 to 200 V AC, 50/60 Hz, Auto-switching (field-replaceable as part of the power supply controller module) |
Power Consumption | 285 VA | 285 VA | 285 VA |
Local Interlock | Key located in front | Key located in front | Key located in front |
Remote Interlock | Terminals located in rear | Terminals located in rear | Terminals located in rear |
Note:
(1) The MAP-200 system has been tested and certified to an altitude of 2,000 m
Specifications | |
Multiple Application Platform | |
Model Overview | |
Description | Part Number |
Mainframes (Required) | |
MAP-200 8-slot mainframe | MAP-280 |
MAP-200 8-slot mainframe factoryreversed configuration | MAP-280R |
MAP-200 3-slot mainframe | MAP-230B |
Power Cords (Required) | |
Australia/China power cord | CORD-AU |
European power cord | CORD-EU |
Japan power cord | CORD-JP |
United Kingdom power cord | CORD-UK |
United States power cord | CORD-US |
Accessories (Optional) | |
MAP-200 stand-alone keypad/display module | MAP-200BKD |
MAP-200BKD keypad/display cable harness kit | MAP-200A01 |
MAP-200 8-slot mainframe 19-inch rack-mount kit | MAP-200A03 |
MAP-200 adaptor kit for single width MAP modules (requires one kit per device) | MAP-200A013 |
MAP-200 adaptor kit for double width MAP modules (requires one kit per device) | MAP-200A013D |
MAP-200BKD keypad/display module rack-mount kit | MAP-200B09 |
MAP-200 3-slot mainframe 19-inch rack-mount kit | MAP-200A10 |