Attribute | Value |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
A wide variety of optical, electrical, and accessory modules support your specific testing requirements.
The Tektronix 80C00 optical sampling modules, when installed in DSA8300 Digital Serial Analyzer sampling oscilloscopes¹, provide complete optical test solutions for telecom (125 Mb/s to 44.50 Gb/s) and datacom (gigabit Ethernet, 10 GbE, 40 GbE, 50G/100G/200G/400G Ethernet, Fibre Channel, and InfiniBand) applications, as well as general-purpose optical component testing.
Other module features include an optical-to-electrical converter, average power monitor, one or more reference receiver filters, a full bandwidth optical path, optional integrated clock recovery², optional electrical clock recovery signal pickoff³ , and a universal optical input connector.
Notes:
¹ Also compatible with DSA8200, TDS/CSA8200, TDS/CSA8000B, and TDS/CSA8000 sampling oscilloscopes.
² 80C07B, 80C08D, and 80C11B modules.
³ 80C10C (with opt. CRTP), 80C12B, 80C14, 80C15, 80C17, and 80C18 modules.
80C15 provides 32 GHz full bandwidth and fully integrated optical reference receivers (ORR) 6 , enabling conformance testing of both single and multi-mode conformance testing at 850,1310 and 1550 nm. The module includes bandwidth filters which support the following rates: 25.781 Gb/s (100GBASESR4, Inifiniband EDR, TDEC), 27.952 Gb/s (OTU-4), and 28.05 Gb/s (32G Fibre Channel).
Key Features |
Optical modules that support optical data rates from 155 Mb/s to 10 Gb/s to 40 Gb/s to 100 Gb/s to PAM4 for 50G/100G/200G/400G |
Optical reference receivers (ORR)³ support specified requirements for standards-mandated compliance testing |
High optical sensitivity, low noise, and wide dynamic range of the optical sampling modules allows accurate testing and characterization of short-reach to long-haul optical communications standards |
Fully calibrated clock recovery solutions – no need to manually calibrate for data pick-off losses |
Calibrated extinction ratio measurements and variable correction ER measurement ensure accuracy and repeatability |
Note:
³ Optical Reference Receiver (ORR) is a 4th-order Bessel-Thompson filter, with a frequency response and tolerances as defined by the standards. Tektronix optimizes the response for best nominal fit and highest quality mask test results.
Specifications | |
80C15 Single/multi-mode multirate datacom and telecom 25 Gb/s, 100 Gb/s | |
Features | Parameters |
Wavelength Range (nm) | 800 - 1600 |
Calibrated Wavelength (± 20 nm) | 850 1310 |
Unfiltered Optical Bandwidth | >32 GHz |
Fiber Input(µm) ¹ | 62.5 |
Typical Mask Test Sensitivity (dBm) | -8 at 1310 nm ⁴ |
RMS Optical Noise (typical at 1310 nm) ⁵ | 10.3 μw (25.78 Gb/s) 10.3 µw (26.5625 Gb/s) 10.3 µw (TDECQ) 10.3 μw (27.95, 28.0 Gb/s) 12.2 μw (32 GHz) |
RMS Optical Noise (max at 1310 nm)⁵ | 12.2 µw (TDEC 16.8 GHz) 12.2 μw (25.78 Gb/s) 12.2 µw (26.5625 Gb/s) 12.2 μw (27.95, 28.0 Gb/s) 14.1 μw (32 GHz) |
Optical Return Loss -Single-Mode (dB) | >24 |
Optical Return Loss -Multi-Mode (dB) | >14 |
Acquisition Delay Adjustment Range on each Channel | N/A |
Power meter range ⁶ | +0 dBm to -30 dBm |
Notes:
1 Modules with fiber inputs of 62.5 µm can accommodate 9 µm (single-mode) as well as 50 µm and 62.5 µm (multi-mode) fibers. Modules with fiber inputs of 50 µm can accommodate 9 µm (single-mode) fibers.
2 When ordered with clock recovery trigger pick-off option (option CRTP), the mask test sensitivity of the 80C10C is reduced by 1 dBm.
3 Low ER signals (ER ≤ 6 dB): signal passes 802.3ae-like mask (scaled horizontally for bit rate); 105 samples in mask. High ER signals (ER > 6 dB): signal passes OC-192-like mask (scaled horizontally for bit rate); 105 samples in mask. Sensitivity expressed as minimum AOP of a high ER signal that passes an ideal signal.
4 The mask test sensitivity of the 80C15/17/18 is reduced by 3 dB for 850 nm signals.
5 The RMS optical noise (both typical and maximum) for wavelengths other than 1310 nm is obtained by multiplying the values in the table above by the following factors— 80C10C: 0.77 for 1550 nm, 80C15: 1.06 for 1550 nm and 0.67 for 850 nm, 80C17/18: 1.1 for 1550 nm, 1.66 for 850 nm.
6 Power meter accuracy = 5% of reading + connector uncertainty for 1550 nm ±20 nm and 1310 nm ±20 nm.
Specifications | |
80C00 Optical Modules; for DSA8300 Sampling Oscilloscope | |
Model Overview | |
Models | Description |
80C07B | Multirate datacom and telecom optical sampling module |
80C08D | Multirate, broad wavelength, high sensitivity 10 Gb/s |
80C10C | Multirate datacom and telecom 25 Gb/s, 40 Gb/s, and 100 Gb/s |
80C11B | Multirate, 10 Gb/s datacom and telecom |
80C12B | Multirate, broad wavelength, high sensitivity datacom and telecom |
80C14 | Multirate, high sensitivity datacom and telecom 10 Gb/s and 14 Gb/s |
80C15 | Single/multi-mode, multirate datacom and telecom 25 Gb/s and 100 Gb/s |
80C17 | Single channel, single/multi-mode, multirate datacom and telecom 25 Gb/s, 100 Gb/s, and PAM4 for 50G/100G/200G/400G |
80C18 | Dual channel, single/multi-mode, multirate datacom and telecom 25 Gb/s, 100 Gb/s, and PAM4 for 50G/100G/200G/400G |
80C20 | Single channel, single-mode, multirate datacom and telecom 25 Gb/s, 40 Gb/s, 100 Gb/s, and PAM4 for 200G/400G |
80C21 | Dual channel, single-mode, multirate datacom and telecom 25 Gb/s, 40 Gb/s, 100 Gb/s, and PAM4 for 200G/400G |
Specifications | |
DSA8300 Series | |
Model Overview | |
Model | Description |
DSA8300 | Digital Serial Analyzer Sampling Oscilloscope |
Optical Modules | |
80C07B | 2.5 GHz single-mode and multi-mode, Amplified (750 to 1650 nm) optical module for multirate datacom and telecom applications w/ optional integrated clock recovery |
80C08D | 9 GHz optical channel; single-mode and multi-mode, Amplified (750 to 1650 nm) optical module optimized for 8.5 to 12.5 Gb/s applications with optional integrated clock recovery |
80C10C | 55/70/80 GHz; Single-mode (1290 to 1330 nm and 1520 to 1620 nm) optical module with reference receiver* filters for multirate datacom and telecom 40 Gb/s and 100 Gb/s (4 × 25 Gb/s) and PAM4 50G/100G/200G/400G at 25+GBd and 53+GBd applications with optional calibrated trigger pick-off for use with external clock recovery instruments (such as the CR286A) |
80C11B | 30 GHz; Single-mode (100 to 1650 nm) optical module with reference receiver* filters for 8.5 to 14.1 Gb/s telecom and datacom standards. Optional, integrated clock recovery for 8.5 to 12.6 Gb/s applications |
Note: