The Keysight 4000 X-Series oscilloscopes are engineered for next-generation performance, delivering waveform update rates 20 times faster than the competition to display the most signal detail. An industry-leading 12.1-inch capacitive touch screen with innovative hardware-based zone touch triggering provides the most intuitive interface to get you answers faster. The 4000 X-Series provides maximum investment protection with fully upgradable 7-instruments-in-1.
Key Features:
Specifications | |
Bandwidth | 200 MHz |
Bandwidth Upgrades | Available |
Channels | 4 |
Max Memory Depth | 4 Mpts |
Max Sample Rate | 5 GSa/s |
Display Size | 12.1 inch |
Waveform Update Rate | 1,000,000 wfms/sec |
ADC Bits | 8 bits |
Special Triggers | edge |
pulse width | |
video | |
protocol decodes | |
zone touch | |
edge then edge | |
pattern | |
runt pulse | |
rise/fall time | |
Nth edge burst | |
setup and hold | |
Operating System | Embedded |
4000 X-Series Specification Overview | ||||||||
4022A | 4024A | 4032A | 4034A | 4052A | 4054A | 4104A | 4154A | |
Bandwith* (–3 dB) | 200 MHz | 200 MHz | 350 MHz | 350 MHz | 500 MHz | 500 MHz | 1 GHz | 1.5 GHz* |
All Channel Real Time Bandwidth | 200 MHz | 200 MHz | 350 MHz | 350 MHz | 500 MHz | 500 MHz | 1 GHz | 1 GHz |
Calculated Rise Time (10 to 90%) | ≤ 1.75 ns | ≤ 1.75 ns | ≤ 1 ns | ≤ 1 ns | ≤ 700 ps | ≤ 700 ps | ≤ 450 ps | ≤ 300 ps |
Input Channels | ||||||||
DSOX | 2 | 4 | 2 | 4 | 2 | 4 | 4 | 4 |
MSOX | 2 + 16 | 4 + 16 | 2 + 16 | 4 + 16 | 4 + 16 | 4 + 16 | 4 + 16 | 4 + 16 |
Maximum ample Rate | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel | 5 GSa/s half channel, 2.5 GSa/s all channel |
Maximum Memory Depth | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels | 4 Mpts half channels, 2 Mpts all channels |
Display Size and Type | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display | 12.1-inch high-definition capacitive touch display |
Waveform Update Rate | > 1 million waveforms per second | > 1 million waveforms per second | > 1 million waveforms per second | > 1 million waveforms per second | > 1 million waveforms per second | > 1 million waveforms per second | > 1 million waveforms per second | > 1 million waveforms per second |
System Bandwidth with N2894A Standard Passive Probe | 200 MHz | 200 MHz | 350 MHz | 350 MHz | 500 MHz | 500 MHz | 700 MHz | 700 MHz |
* 1.5 GHz real time bandwidth in half-channel mode or full channel equivalent time mode
Specifications | ||||
Overview of the Keysight InfiniiVision X-Series Oscilloscopes | ||||
Model | InfiniiVision 1000 X-Series | InfiniiVision 2000 X-Series | InfiniiVision 3000T X-Series | InfiniiVision 4000 X-Series |
Analog Channels | 2 and 4 | 2 and 4 | 2 and 4 | 2 and 4 |
Bandwidth (upgradable) | 50, 70, 100, 200 MHz | 70, 100, 200 MHz | 100, 200, 350, 500 MHz, 1 GHz | 200, 350, 500 MHz, 1 GHz, 1.5 GHz |
Digital Channels | External trigger can be used as a 3rd digital channel for 2 channel model | 8 (MSO models or upgrade) * | 16 (MSO models or upgrade) | 16 (MSO models or upgrade) |
Maximum Sample Rate | 2 GSa/s | 2 GSa/s | 5 GSa/s | 5 GSa/s |
Maximum Memory Depth | Up to 2 Mpts standard | 1 Mpt/channel | 4 Mpts | 4 Mpts |
Waveform Update Rate | Up to 200,000 wfms/sec | Up to 200,000 wfms/sec | > 1,000,000 wfms/sec | > 1,000,000 wfms/sec |
Display | 7-inch display | 8.5-inch display | 8.5-inch capacitive touch display | 12.1-inch capacitive touch display |
Zone Touch Trigger | No | No | Standard | Standard |
WaveGen 20-MHz Function/ Arbitrary Waveform Generator | Single-channel function only (standard on G models) | Single-channel function only (option) | Single-channel AWG (option) | Dual-channel AWG (option) |
Integrated Digital Voltmeter (standard) | Yes | Yes | Yes | Yes |
Integrated Hardware Counter (standard) | 5-digits | 5-digits | 5-digits, 8-digits - totalizer | 5-digits |
Serial Protocol Analysis | I 2C, UART( standard on all models) SPI, CAN/LIN (standard on DSO models) | Yes (optional: CAN, LIN, I²C, SPI, RS232/UART) * | Yes (optional: ARINC 429, CAN/CANdbc/CAN-FD/LIN/LIN symbolic, SENT, FlexRay, I2C, I2S, LIN, MIL-STD-1553, SPI, UART/RS232, CXPI, Manchester/NRZ) | Yes (optional: ARINC 429, CAN/CAN-dbc/CANFD/LIN/LIN symbolic, SENT, FlexRay, I2C, I2S, LIN, MIL-STD-1553, SPI, UART/RS232, USB 2.0, CXPI, Manchester/NRZ) |
Segmented Memory | Yes (standard on DSO model) | Standard | Standard | Standard |
Mask/Limit Testing | Yes (standard on DSO model) | Yes (option) | Yes (option) | Yes (option) |
Power Analysis | No | No | Yes (option) | Yes (option) |
USB 2.0 Signal Quality test | No | No | No | Yes (option) |
HDTV Analysis | No | No | Yes (option) | Yes (option) |
Advanced Waveform Math | No | Standard | Standard | Standard |
Connectivity | Standard USB 2.0, LAN | Standard USB 2.0 (LAN/video option) (GPIB option) | Standard USB2.0 (LAN/video option) (GPIB option) | Standard USB2.0, LAN, video out (GPIB option) |
* The digital channels and serial protocol analysis cannot be used simultaneously on 2000 X-Series.