The ACD-14 PLUS clamp meter works as both an HVAC multimeter and electrical multimeter with a versatile set of features, including microamps, capacitance, frequency and temperature with included thermocouple.
The dual displays show amps and volts simultaneously, useful for measuring voltage drop under load. The thinner jaws of this digital clamp multimeter enable access to tight measurement areas and still handles conductors up to 1″ (25 mm).
Key Features |
Dual displays permit simultaneous reading of amps and volts |
Measures AC Current to 600A and AC/DC Voltage to 600 V |
Measures frequency, capacitance to 3000 µF, and resistance to 40MΩ |
Measures temperature with K-type thermocouple probe |
Includes micro amps measurement for testing flame sensors |
Diode test quickly finds voltage drops |
Continuity beeper detects opens and shorts |
Auto ranging instantly selects correct range |
Hold and maximum reading functions |
New thin jaws, 5 mm thinner than standard digital clamp meters make it easier to access conductors in tight spaces |
Accommodates conductors up to 1.0″ (25 mm) in diameter |
Auto power off and low battery indication helps you make the most of battery life |
Rubber, over-molded case absorbs shock |
Specifications |
|
|
Dual Display Clamp Multimeter with Temperature Model Overview |
|
|
Model | ACD-14 PLUS | ACD-14 TRMS-PLUS |
True-rms | – | • |
AC Voltage | 4.000 V
40.00 V
400.0 V
600 V
| 4.000 V
40.00 V
400.0 V
600 V
|
DC Voltage | 400.0 mV
4.000 V
40.00 V
400.0 V
600 V
| 400.0 mV
4.000 V
40.00 V
400.0 V
600 V
|
AC Current | 40.00 A
400.0 A
600 A
| 40.00 A
400.0 A
600 A
|
Resistance | 400.0 O
4.000 kO
40.00 kO
400.0 kO
4.000 MO
40.00 MO
| 400.0 O
4.000 kO
40.00 kO
400.0 kO
4.000 MO
40.00 MO
|
Capacitance | 500.0 nF
5.000 µF
50.00 µF
500.0 µF
3000 µF
| 500.0 nF
5.000 µF
50.00 µF
500.0 µF
3000 µF
|
Frequency | 40 Hz → 400 Hz with Jaw
10 Hz → 100 kHz with test leads
| 40 Hz → 400 Hz with Jaw
10 Hz → 100 kHz with test leads
|
Temperature | -4 °F → 999 °F (-20 °C → 537 °C) | -4 °F → 999 °F (-20 °C → 537 °C) |
Dual Displays | • | • |
Micro Amps | • | • |
Accommodates Conductors | up to 1.0″ (25 mm) in diameter | up to 1.0″ (25 mm) in diameter |
Display | 3-3/4 digits 4000 counts, dual LCD displays | 3-3/4 digits 4000 counts, dual LCD displays |
Update Rate | 3 per second nominal | 3 per second nominal |
Polarity | Automatic | Automatic |
Operating Temperature | 0°C to 40°C (32°F to 104°F) | 0°C to 40°C (32°F to 104°F) |
Power Supply | Two 3V alkaline button batteries
(ANSI/NEDA-5004LC, IEC-CR2032)
| Two 3V alkaline button batteries
(ANSI/NEDA-5004LC, IEC-CR2032)
|