This professional camera features SuperResolution which captures and combines 4x the data to create a 640 x 480 image. Features an increased sensitivity to visualize temperature differences, and NETD is ≤0.025 at 30°C target temperature (25mK).
Key Features |
Increased sensitivity to visualize temperature differences, NETD is ≤0.025 at 30°C target temp (25 mK) |
Easier to visualize and diagnose issues with sharper onscreen images, multiple rectangle markers and 9 color palettes |
More intuitive visual interface, improved, user-tested, touch screen interface |
More flexibility to visualize target, tiny-to-large with interchangeable smart lenses - no calibration required, 2x and 4x telephoto, wide angle and macro lens compatibility |
Capture a clear, accurate image focused throughout the field of view with MultiSharp™ Focus |
Get an instant in-focus image of your designated target - LaserSharp® Auto Focus uses a built-in laser distance meter that calculates and displays the distance from your designated target |
Get 4x the pixel data with SuperResolution, which captures multiple images and combines them to create a 640 x 480 image |
Save time - wirelessly sync images directly from your camera to the Fluke Connect® system, and attach to an asset record or work order |
Reduce the need take notes in the field with IR-PhotoNotes™ and voice annotations |
Highlight areas that are outside your pre-set ‘normal' temperature ranges quickly with color alarms |
Applications |
Thermal utility inspections |
Thermal industrial application troubleshooting |
Oil and gas inspections |
Specifications | ||
Fluke TI450 PRO Infrared Camera | ||
Model Overview | ||
Model | Fluke TI450 PRO | Ti480 PRO |
Color Alarms (Temperature Alarms) | High temperature, low temperature, and isotherms (within range) | High temperature, low temperature, and isotherms (within range) |
Infrared Spectral Band | 7.5 to 14 μm (long wave) | 7.5 to 14 μm (long wave) |
Operating Temperature | 14 to 122°F (-10 to 50°C) | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -4 to 122°F (-20 to 50°C) without batteries | -4 to 122°F (-20 to 50°C) without batteries |
Spot Temperature | Hot and cold spot markers | Hot and cold spot markers |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic Compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Dimensions | 10.9 x 4.8 x 6.5" (27.7 x 12.2 x 16.7 cm) | 10.9 x 4.8 x 6.5" (27.7 x 12.2 x 16.7 cm) |
Weight (battery included) | 2.3 lb (1.04 kg) | 2.3 lb (1.04 kg) |