配置型號包含以下特性:
RF & Microwave Spectrum AnalyzersSpectrum Analyzers-Economy20GHz <= 50GHzDC <= 1kHz特性 | 參數 |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
Low Frequency (range) | DC <= 1kHz |
The MXA is the optimum choice as you take new-generation wireless devices to market. It has the flexibility to quickly adapt to evolving test requirements, today and tomorrow. In R&D, characterize signals from virtually any wireless device quickly and confidently with up-to-date parametric or RF functional tests.
To shorten design verification test times, the intuitive multi-touch interface minimizes measurement complexity, even when working with cutting-edge devices. In 5G manufacturing, the MXA helps you increase throughput and yield while minimizing costs with the fastest, most accurate signal and spectrum measurements in a midrange benchtop analyzer.
Key Features:
Specifications | |
MXA Signal Analyzer | |
Features | Parameters |
Frequency Options | n/a |
Real-Time Bandwidth Options | 255, 510 MHz |
DANL @1 GHz | -172 dBm/Hz |
Maximum Analysis Bandwidth | 255 MHz |
Phase Noise @1 GHz (10 kHz offset) | -129 dBc/Hz |
Spur Free Dynamic Range | 72 dBc |
Overall Amplitude Accuracy | 0.41 dB |
Performance Level | n/a |
Applications-Cellular | GSM/EDGE LTE/LTE-Advanced W-CDMA/HSPA/HSPA+ W-CDMA/HSPA+ 5G NR |
Applications-General Purpose | 89600 VSA Software Analog Demodulation Noise Figure Phase Noise Real-Time Spectrum Analysis Vector Modulation Analysis EMI emission measurement |
Minimum Duration for 100% Probability of Intercept | 3.57 μs |
Specifications | |
MXA Signal Analyzer | |
Accessories and Options | |
Model Number | Description |
Bandwidth | |
N9021B-B2X | Analysis bandwidth, 255 MHz |
N9021B-B5X | Analysis bandwidth, 510 MHz |
Calibration Options | |
N9021B-UK6 | Commercial calibration certificate with test data |
Connection Options | |
N9021B-CR3 | Connector Rear, Wideband IF output |
N9021B-CRP | Connector, programmable rear IF output |
N9021B-YAS | Y-Axis Screen Video Output |
External Mixing | |
N9021B-EXM | External mixing |
Frequency Range | |
N9021B-532 | Frequency Range, 10 Hz to 32 GHz |
N9021B-544 | Frequency Range, 10 Hz to 44 GHz |
N9021B-550 | Frequency Range, 10 Hz to 50 GHz |
Performance Options | |
N9021B-NF2 | Noise floor extension, instrument alignment |
N9021B-PFR | Precision frequency reference |
N9021B-DUA | Duplex IF RTSA |
N9021B-EA3 | Electronic attenuator, 3.6 GHz |
N9021B-EDP | Enhanced display package license |
N9021B-FP2 | Fast power, up to maximum available analysis bandwidth |
N9021B-FT1 | Frequency mask trigger, basic detection |
N9021B-FT2 | Frequency mask trigger, optimum detection |
N9021B-MPB | Microwave preselector bypass |
N9021B-RBE | Resolution bandwidth extended |
N9021B-EMC | Basic EMC Functionality |
Preamplifier | |
N9021B-P32 | Preamplifier, 32 GHz |
N9021B-P44 | Preamplifier, 44 GHz |
N9021B-P50 | Preamplifier, 50 GHz |