The FSPN phase noise analyzer and VCO tester features very high sensitivity and metrological accuracy and provides highest reliability. It measures phase noise on highly stable sources like synthesizers, VCOs, OCXOs and DROs found in radar and satellite applications.
Equipped with two low phase noise synthesizers and a real-time cross correlation engine for increased measurement sensitivity, just a few correlations are needed to measure very high-quality oscillators, synthesizers or VCOs in production. Increase the number of correlations to characterize the most sensitive commercially available synthesizers and oscillators in R&D.
The FSPN phase noise analyzer and VCO tester has everything needed to keep up with demanding measurements from lab to production. With its extremely high measurement speed and easy usability, it is the perfect instrument for efficient phase noise analysis tasks both in R&D and on production lines.
Thanks to its low‑noise internal local oscillators, the FSPN measures all commercially available synthesizers and oscillators without any additional options.
Key Features |
Frequency range from 1 MHz to 8 GHz/26.5 GHz |
Very high sensitivity for phase noise measurements thanks to dual synthesizers and cross-correlation included in the base unit, typ. –163 dBc (1 Hz) at 1 GHz carrier frequency and 10 kHz offset |
Pure phase noise analyzer and VCO tester with high measurement speed due to hardware-implemented real-time cross-correlation |
Extremely low-noise internal DC sources for automatic VCO characterization |
High measurement speed with hardware-implemented real-time cross-correlation |
Simultaneous measurement of phase noise and amplitude noise |
Benefits | |
Measurement Speed taken to its Limit | Save time and multiply your measurement throughput in production Speed up the development of your devices |
Phase Noise Measurements with Highest Sensitivity | Cross-correlation for improved phase noise sensitivity Display multiple measurements in parallel |
Fastest VCO Characterization | Harmonics suppression measurement Enhanced tuning voltage capabilities |
Transient Response Analysis | Up to 8 GHz wideband analysis for frequency and phase measurements in time domain Trigger capabilities for reproducible measurements on phase or frequency deviation |
Specifications | |
FSPN Phase Noise Analyzer and VCO Tester | |
Features | Parameters |
Display | 30.7 cm (12.1"), WXGA color touchscreen |
Resolution | 1280 × 800 pixel (WXGA resolution) |
Pixel Failure Rate | < 1 × 10⁻⁵ |
Data Storage Internal (Standard) | solid state disk ≥ 128 Gbyte |
Data Storage External | supports USB 2.0 compatible memory devices |
Operating Temperature Range | +5 °C to +40 °C |
Permissible Temperature Range | 0 °C to +55 °C |
Storage Temperature Range | –40 °C to +70 °C |
Climatic Loading (without condensation) | +40 °C at 90 % rel. humidity In line with EN 60068-2-30 |
Altitude Max. Operating Altitude (above sea level) | 4600 m (approx. 15100 ft) |
Mechanical Resistance Vibration (sinusoidal) | 5 Hz to 55 Hz Displacement: 0.15 mm constant amplitude (1.8 g at 55 Hz), 55 Hz to 150 Hz Acceleration: 0.5 g constant, in line with EN 60068-2-6 |
Mechanical Resistance Vibration (random) | 10 Hz to 300 Hz Acceleration 1.2 g (RMS), in line with EN 60068-2-64 |
Mechancial Resistance Shock | 40 g shock spectrum In line with MIL-STD-810E method no. 516.4, procedure I, MIL-PRF-28800F, class 3 |
EMC | IEC/EN 61326-1 ᴬ ᴮ IEC/EN 61326-2-1 CISPR 11/EN 55011 ᴬ IEC/EN 61000-3-2 IEC/EN 61000-3-3 |
Recommended Calibration Interval | 1 Year |
Input Voltage Range (AC) | 100 V to 240 V |
Supply Frequency (AC) | 50 Hz to 60 Hz/400 Hz |
Max. Input Current | 7.3 A to 4.6 A (100 V to 240 V) |
Power Consumption FSPN8 FSPN26 | 210 W 235 W |
Safety | In line with: IEC 61010-1 EN 61010-1 UL 61010-1 CAN/CSA-C22.2 No. 61010-1 |
Test Marks | VDE ᴄCSAᴜs |
Dimensions (W x H x D) | Including front handles and rear feet: 462 mm × 240 mm × 504 mm (18.15 in × 9.44 in × 19.81 in) |
Weight | FSPN8: 20.5 kg (45.2 lb) FSPN26: 22 kg (48.5 lb) |
Notes:
ᴬ Emission limits for class A equipment.
ᴮ Immunity test requirement for industrial environment (EN 61326 table 2).
Specifications | |||
FSPN Phase Noise Analyzer and VCO tester | |||
Model Overview | |||
Model | Order Number | Frequency Range | Phase Noise |
Phase Noise Analyzer and VCO Tester | 1322.8003.06 | 1 MHz - 8 GHz | < –163 dBc (1 Hz) (f = 1 GHz, 10 kHz offset) |
FSPN26 Phase Noise Analyzer and VCO Tester | 1322.8003.24 | 1 MHz - 26.5 GHz | < –163 dBc (1 Hz) (f = 1 GHz, 10 kHz offset) |
Specifications | ||
FSPN Phase Noise Analyzer and VCO Tester | ||
Model Overview | ||
Model | Order Number | Description |
FSPN8 | 1322.8003.06 | Phase Noise Analyzer and VCO Tester, 1 MHz to 8 GHz Included Accessories: Power Cable Quick Start Guide |
FSPN26 | 1322.8003.24 | Phase Noise Analyzer and VCO Tester, 1 MHz to 26.5 GHz Included Accessories: Power Cable Quick Start Guide Adapter, 3.5 mm (APC3.5-compatible), female/female |
Recommended Extras | ||
PCK | 0292.2013.10 | IEC/IEEE bus cable, length: 1 m |
PCK | 0292.2013.20 | IEC/IEEE bus cable, length: 2 m |
ZZF-511 | 1174.8825.00 | Front cover |
ZZA-KN5 | 1175.3040.00 | 19" rack adapter |
Matching pads, 50/75 Ω | ||
RAM | 0358.5414.02 | L section, matching at both ends |
RAZ | 0358.5714.02 | Series resistor, 25 Ω, matching at one end (taken into account in instrument function RF INPUT 75 Ω) |
High Power Attenuators | ||
RBU100 | 1073.8495.03 | 100 W, 3 dB, 1 GHz |
RBU100 | 1073.8495.06 | 100 W, 6 dB, 1 GHz |
RBU100 | 1073.8495.10 | 100 W, 10 dB, 1 GHz |
RBU100 | 1073.8495.20 | 100 W, 20 dB, 1 GHz |
RBU100 | 1073.8495.30 | 100 W, 30 dB, 1 GHz |
RBU50 | 1073.8695.03 | 50 W, 3 dB, 2 GHz |
RBU50 | 1073.8695.06 | 50 W, 6 dB, 2 GHz |
RBU50 | 1073.8695.10 | 50 W, 10 dB, 2 GHz |
RBU50 | 1073.8695.20 | 50 W, 20 dB, 2 GHz |
RBU50 | 1073.8695.30 | 50 W, 30 dB, 2 GHz |
RDL50 | 1035.1700.52 | 50 W, 20 dB, 6 GHz |
Connectors and Cables | ||
-- | 3587.7829.00 | Coaxial adapter, N (f)/3.5 mm (f), APC3.5-compatible; for R&S®FSPN8 |
-- | 3587.7793.00 | Coaxial adapter, 3.5 mm (f/f), APC3.5-compatible; for R&S®FSPN26 |
-- | 3586.9970.00 | RF cable, length: 50 cm, SMA (f/f) |
-- | 1065.9480.00 | Probe power connector, 3-pin |
RT-ZA9 | 1417.0909.02 | Type N adapter, for R&S®RT-Zxx oscilloscope probes |
DC Block | ||
FSE-Z4 | 1084.7443.02 | DC block, 10 kHz to 18 GHz (type N) |