RF & Microwave Network AnalyzersTest Sets85GHz <50GHz <= 85GHz特性 | 參數 |
---|---|
High Frequency (range) | 85GHz < |
Low Frequency (range) | 50GHz <= 85GHz |
N5262BWxx transceiver modules have both a source and measurement receiver and can be used with the network analyzer to make S-parameter reflection measurements. Another transceiver or receiver module is required to make transmission measurements. Transceiver modules are also known as transmission/reflection modules.
Specifications | |||||||||
Keysight N5262BW08 | |||||||||
VDI frequency extenders | 522xB PNA / N524xB PNA-X withN5262BWxx | ||||||||
Wavegude Band | Frequency Coverage (GHz) Standard | Frequency Coverage (GHz) Extended2 | Test Port Power (dBm typical) | Limit (estimate, dBm, damage) TxRx, TxRef | Directivity (dB) | Dynamic range (BW = 10 Hz,dB) Typical | Dynamic range (BW = 10 Hz,dB) Minimum | Stability Magnitude (± dB) | Stavility Phase (± deg) |
WR15 | 50-75 | 47-77 | 13 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR15-P | 50-75 | 13 | 30 | 30 | |||||
WR12 | 60-90 | 55-95 | 18 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR12 SE Option | 60-90 | 55-90 | 13 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR12-P | 60-90 | 13 | 30 | 30 | |||||
WR10 | 75-110 | 67-115 | 18 | 30 | 30 | 120 | 110 | 0.1 | 1.5 |
WR10 SE Option | 75-110 | 67-110 | -1 | 20 | 30 | 120 | 110 | 0.1 | 1.5 |
WR10-P | 75-110 | 13 | 20 | 30 | |||||
WR10-P SE Option | 75-110 | -1 | 20 | 30 | |||||
WR8.0 | 90-140 | 16 | 30 | 30 | 120 | 110 | 0.15 | 2 | |
WR6.5 | 110-170 | 13 | 30 | 30 | 120 | 110 | 0.25 | 4 | |
WR6.5-P | 110-170 | 13 | 30 | 30 | |||||
WR5.1 | 140-220 | 6 | 30 | 30 | 120 | 110 | 0.25 | 4 | |
WR4.3 | 170-260 | 4 | 28 | 30 | 115 | 110 | 0 | 4 | |
WR3.4 | 220-330 | 1 | 26 | 30 | 115 | 105 | 0.3 | 6 |
Specifications | ||||||||
Keysight N5262BW08 | ||||||||
OML Frequency Extenders | N522xB PNA / N524xB PNA-X withN5256A/BWxx | |||||||
Wavegude Band | Frequency Coverage (GHz) Standard | Test Port Power (dBm typical) | Limit (estimate, dBm, damage) TxRx, TxRef | Directivity (dB) | Dynamic range Typical | Dynamic range Minimum | Stability Magnitude (± dB) | Stability Phase (± deg) |
WR15 | 50-75 | 8 | 20 | 35 | 105 | 92 | 0.2 | 2 |
WR12 | 60-90 | 5 | 20 | 35 | 105 | 92 | 0.2 | 2 |
WR10 | 75-110 | 5 | 20 | 35 | 110 | 95 | 0.2 | 2 |
WR8.0 | 90-140 | 4 | 20 | 33 | 105 | 90 | 0.3 | 3 |
WR6.5 | 110-170 | -10 | 20 | 30 | 95 | 80 | 0.4 | 5 |
WR5.1 | 140-220 | -13 | 13 | 30 | 95 | 80 | 0.4 | 6 |
WR3.4 | 220-325 | -23 | 13 | 30 | 75 | 60 | 0.4 | 8 |
2. N5252AWxx is available for WR15, WR12, WR10, and WR6.5 only. Extended Frequency coverage not specified for this configuration. Standard VDI extension modules (N5262BWxx) can be used with P500xxA/M980xA and P937xA/M937xA with external N5252APXI adapter module.