配置型號包含以下特性:
RF & Microwave Network AnalyzersNetwork Analyzers >=20GHz20GHz <= 50GHz1MHz <= 10MHz2.4mm-Male (Jack)選項 | 說明 |
---|---|
Precision frequency reference for R&S®ZNA (Hardware option) | |
2nd internal LO source, for R&S®ZNA (4 ports) external access up to 26.5 GHz requires option R&S®ZNA-B8 in addition (Hardware option) | |
Memory extension for long time data recording, data streaming, extended pulse pattern recording for R&S®ZNA (Hardware option) | |
mmWave converter LO, 10 MHz to 26.5 GHz, for R&S®ZNA Enables mmWave converter setups utilizing a R&S®ZNA, or general external (IF) mixing. (used for mmWave-converter setups: Requires one of options R&S®ZNA-B26, "Direct IF access", or R&S®ZNA-B5, "2nd internal LO src". Used as general mixer LO: Requires R&S®ZNA-B5, "2nd internal LO src") (Hardware option) | |
Direct IF access for R&S®ZNA (Hardware option) | |
Additonal trigger and control I/O ports for R&S®ZNA 3 trigger in, 4 trigger out, 4 pulse modulator control ports (I/O switchable), busy and ready for trigger indication, noise source control (28 V), RF OFF control input (Hardware option) | |
Spectrum analyzer mode for R&S®ZNA (software license) | |
Time domain analysis (TDR) for R&S®ZNA (software license) | |
Scalar mixer measurements and arbitrary frequency-converting measurements for R&S®ZNA (software license) | |
Vector corrected converter measurements (without reference mixer and phase reference) for R&S®ZNA requires R&S®ZNA-K4 (software license) | |
Control of the internal phase coherent RF sources for R&S ZNA (software license) | |
Measurements on pulsed signals (Pulse configuration, pulse profile and pulse train measurements) for R&S®ZNA requires R&S®ZNA-K17 (software license) | |
Group delay measurements on frequency converters without LO access for R&S®ZNA (4 ports recommended) requires R&S®ZNAxx-B16/R&S®ZNA-K4 (software license) | |
Increased IF bandwidth up to 30 MHz for R&S®ZNA (software license) | |
1 mHz frequency resolution for R&S®ZNA (software license) | |
Extended time domain analysis incl. eye diagram for R&S®ZNA requires R&S®ZNA-K2 (software license) | |
Noise figure measurements on 2-port devices for R&S ZNA (R&S ZNAxx-B16/-B2x recommended) (software license) | |
Realtime measurement uncertainty analysis for R&S ZNA Including pre-installed Swiss Metrology Institute METAS Software: VNA tools (software license) (retrofit in factory only) | |
True differential operation mode (stimulation and measurement) incl. imbalance sweep modes for R&S ZNA (4 ports) (software license) requires R&S ZNA-K6 | |
Eazy De-embedding (EZD) based on IEEE 370 for R&S ZNA (retrofitting possible in service) (software license) | |
In-Situ De-embedding (ISD) that covers IEEE 370 for R&S ZNA (retrofitting possible in service) (software license) | |
Smart Fixture De-embedding (SFD) for R&S ZNA (retrofitting possible in service) (software license) | |
Delta-L 4.0 PCB characterization, complete 1L, 2L, and 3L analysis based on Intels Delta-L 4.0 methodology for R&S ZNA (retrofitting possible in service) (software license) | |
3rd and 4th internal source for R&S®ZNA43 (4 ports) (Hardware option) | |
Direct source and receiver access for R&S®ZNA43 (4 ports) Installation ex factory only (Hardware option) | |
Source step attenuator for port 1, mechanical, 70 dB in 10 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Source step attenuator for port 2, mechanical, 70 dB in 10 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Source step attenuator for port 3, mechanical, 70 dB in 10 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Source step attenuator for port 4, mechanical, 70 dB in 10 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Receiver step attenuator for port 1, mechanical, 35 dB in 5 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Receiver step attenuator for port 2, mechanical, 35 dB in 5 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Receiver step attenuator for port 3, mechanical, 35 dB in 5 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Receiver step attenuator for port 4, mechanical, 35 dB in 5 dB steps for R&S®ZNA43 Installation ex factory only (Hardware option) | |
Internal pulse modulator for port 1 for R&S®ZNA43 (Hardware option) | |
Internal pulse modulator for port 2 for R&S®ZNA43 (Hardware option) | |
Internal pulse modulator for port 3 for R&S®ZNA43 (Hardware option) | |
Internal pulse modulator for port 3 for R&S®ZNA43 (Hardware option) | |
Direct source monitor access on port 1 and port 3 before the source step attenuator for R&S®ZNA43 (4 ports) requires R&S®ZNA43-B16/-B21/-B23 Upgrade / retrofit by R&S service Memmingen only. (Hardware option) | |
Internal combiner, port 1 | |
Low noise pre-amplifier at receiver port 2 | |
Spur magnitude reduction for enhanced spectral purity with low RF output power, for Port 1. (Required: R&S ZNA43-B31, recommended: R&S ZNA43-B16, R&S ZNA43-B161, R&S ZNA43-B21) |
顯示中 1 - 3 的 3 結果
產品編號: P-558731
產品編號: P-620153
產品編號: P-181135
顯示中 1 - 3 的 3 結果