配置型號包含以下特性:
Power Supplies / Electronic LoadsAC Power Supplies312V16A5550W11/3特性 | 參數 |
---|---|
Maximum Voltage | 312V |
Maximum Current | 16A |
Maximum Power | 5550W |
Channel/Port Count | 1 |
Phases | 1/3 |
The SW5550A SmartWave (SW) 3 Phase 5550VA AC power source offers powerful waveform creation for ATE and power line disturbance simulation testing. Three separate arbitrary waveform generators enable the SmartWave to create independent, complex waveforms on all three phases simultaneously. The SmartWave is designed to meet waveform requirements including DC content (up to 312V), low distortion (THD 0.25% to 100 Hz), low noise and ripple, plus full compliance testing to various EMC and avionics standards.
Designed to Meet the Following:
ER configurations:
SW5550A/1-3-2
EGR-SW5550A/2-3-2
Input Frequency Range: 47 to 63 Hz
Input Voltage Ranges:
Factory configured 187 to 264 VRMS, 3 L-L (3 wire), or 342 to 457 VRMS, 3 L-L (4 wire). A chassis ground is also required. 115 or 230 VAC single-phase is required for PDU in 10.5-21 kVA systems. (400 Hz input allowed with PFC option)
AC or DC Output Voltage: 0 to 156 VRMS L-N, range 1; 0 to 312 VRMS L-N, range 2
Output Current Per Phase: (3 Phase Total) 16A at 115V in the 156V range; 8.0A at 230V in 312V range (1850 VA maximum) Note: Higher currents may be achieved in 10.5-21 kVA systems.
Crest Factor: 4.0 (peak output current to RMS output current)
Output Frequency Range: DC or 40 Hz to 5 kHz. For output frequencies greater than 1 kHz, the max slew rate allowed is 1 kHz per second.
Output Power: 1750 VA: 1, 3500 VA: 1 or 2, 5550 VA: 1 or 3 (systems up to 21,000 VA)