配置型號包含以下特性:
Power Quality & Electrical TestEMC Test Equipment264V特性 | 參數 |
---|---|
Maximum Voltage | 264V |
The PFM 200N100.1 and PFM 200N200 have been designed to fully meet the requirements for E10, E13 and E14 of the LV 124 and the E48-09 of the LV 148. It also allows to perform microinterruptions with fast rise/fall time of as low as 200ns as required by GMW 3172, sec. 9.2.18.
The PFM 200N series includes a switch for the power supply line from 100 mA to 200A and a separate switch in the ground return path. These switches can support very high inrush currents up to several hundreds of Ampères. For signal- and data lines an additional 16 channel switch is included with current rating from 100 uA to 2 A per channel.
Key Features |
Switch for Power supply (100 A / 200 A) and signal/data lines (2 A) |
Pulses E10 and E13 of the LV 124/LV 148 standard |
Bidirectional current direction |
Separate switch in the ground line |
Rise/fall time less than 200ns |
Built in short-circuit switch <100 mohm |
Rated voltage ±100 VDC |
short-circuit-proof |
Specifications | |
PFM 200N Series Automotive Power Fail Simulator; for OEM LV124 and LV 148 and other Manufacturer Standards | |
Feature | Parameter |
Power Line Switch | |
Switch | 2 Switches in the circuit - DC+ Power line - DC- Ground line |
DUT Voltage | ± 100 VDC |
DUT Current | 100 mA to 100 A 200 A @ 25 °C |
Current Direction | Bidirectional |
Switching Time | < 200 ns (rise/fall time) |
Repetition Rate | 10 µs - 1 h |
Drop Duration | 1 µs - 1 h |
Peak Current | 400 A for 200 ms 1,350 A for 1 ms automatic switch-off if I > 1,350 A |
Safety | Short circuit protection |
Switch for Signal (and Dateline Switch) | |
Channels | 16 independ switched lines |
DUT Voltage | Max. ± 40 VDC |
DUT Current | 100 µA to 2 A, per channel @ 25 °C |
Current Direction | Bidirectional |
Switching Time | < 1 µs (rise/fall time) |
Repetition Rate | 500 µs - 1 h |
Drop Duration | 1 µs - 1 h |
Bandwidth | 50 MHz / 3 dB |
Peak Current | 5 A for 200 ms |
Safety | Short circuit protection |
Connector | PHOENIX, DFMC connector 1.5 mm2 Push-in-spring cage connection |
General Switch | |
Switch Impedance | Power lines: < 50 mOhm Data lines: < 500 mOhm |
Internal Switch | Short circuit switch (DC+ to DC-), impedance <100 mOhm) |
Internal Switch | 100 mOhm, per LV 124 |
Internal Switch | Low |
Internal Switch | High |
Trigger | |
Trigger Out | BNC Plug at the front panel, Automatic release of the events Trigger for oscilloscope, negative slope 15 V |
Trigger In | BNC Plug at the front panel, External release of a single event Pull down |
Protection | |
DC Input Protection | Max. voltage ±100 V Clamped > 100 VDC |
DC Input Protection | Max. voltage ±40 V Clamped > 40 VDC |
Over Temperature | NTC measurement on each mosfet switch |
Over Current | On each mosfet switch electronic protection |
Current Measurement | Overload measured at output |
Interface | |
Frame bus | Control cable to AutoWave |
Monitor Output | DUT out, differential, BNC plug on front panel Ratio 1:20 |
Suitable BUS Systems for Dataline | |
BUS Systems | Low Speed Can 100 kbit High Speed Can 500 kbit LIN Bus 19200 Baud FlexRay 10 Mbit |
General | |
Dimensions | 19"/3 HU 448 mm x 536 mm x 154 mm |
Weight | approx. 10.5 kg |
Supply Voltage | 100 V - 265 VAC, 50/60 Hz |
Fuses | 2 x 2 AT |
Reference Temperature | 23 °C ±5 °C |
Temperature | 10 °C to 35 °C |
Humidity | 25 % to 75 %, non condensing |
Atmospheric Pressure | 86 kPa (860 mbar) to 106 kPa (1 060 mbar) |
Specifications | |
PFM 200N Series Automotive Power Fail Simulator | |
Model Overview | |
Model | Description |
PFM 200N100.1 | DUT current 100 mA to 100 A |
PFM 200N200 | DUT current 100 mA to 200 A |