配置型號包含以下特性:
Oscilloscopes & Logic AnalyzersOscilloscopes 8GHz - < 20GHz10GHz <= 20GHz480 GS/s特性 | 參數 |
---|---|
High Frequency (range) | 10GHz <= 20GHz |
Channel/Port Count | 4 |
Maximum Sample/Data Rate | 80 GS/s |
Keysight DSAV134A Infiniium V-Series oscilloscopes provide industry-leading accuracy that ensures greater insights in analysis and debug of high-speed designs.
The Infiniium V-Series family has the best-in-class signal integrity real-time oscilloscopes in the industry, delivering the most margin for your design validation. They are ideal for spectral analysis of transients and wideband RF applications.
DSA models come standard with 100 Mpts/channel, EZJIT Complete (N8823B), and Serial Data Analysis (E2688A). EZJIT Complete software (N8823B) includes all of the advanced jitter analysis features of EZJIT (E2681A) and EZJIT Plus (N5400A) and adds vertical noise analysis capabilities.
Key Features |
13 GHz analog bandwidth (upgradable). |
4 analog channels. |
Capture a longer signal trace with up to 80 GSa/s sample rate and 2 Gpts of acquisition memory. |
Low noise (1.09 mVrms at 50 mV/div) and jitter measurement floor (100 fs). |
See better measurement accuracy with ENOB values in excess of 5.5 and a SFDR exceeding 50 dBC improve your testing with the broadest range of jitter, trigger, analysis and protocol tools (featuring PrecisionProbe). |
Specifications | |
DSAV134A Infiniium V-Series Oscilloscope | |
Features | Parameters |
Bandwidth | 13 GHz |
Bandwidth Upgrades | n/a |
Channels | 4 |
Max Memory Depth | 2 Gpts |
Max Sample Rate | 80 GSa/s (2-channels), 40 GSa/s (4-channels) |
Display Size | n/a |
Waveform Update Rate | n/a |
ADC Bits | 8 bits |
Noise Floor | n/a |
Minimum Rise/Fall Time | 33.8 ps (10-90%), 23.9 (20-80%) |
Built-In Instruments (Optional) | n/a |
Special Triggers | n/a |
Protocol Trigger & Decodes | n/a |
Hardware Serial Trigger | Yes |
Applications | n/a |
Operating System | n/a |
Real-Time | Yes |
Benefits | |
PRBS Error Detector | Industrys First PRBS error detector can trigger and display the bit error of the PRBS-7, 15, 23 and 31 signals. It identifies the error when the pattern does not match the expected PRBS pattern that has been set in the oscilloscope. When the next error happens, the oscilloscope will replace the display with the next bit error. This allows you to discover if the error is related to the bit pattern, which is related to Inter-Symbol Interference (ISI). The hardware serial trigger provides an eyescan plot to show the signal quality of the signal received. |
Wideband and Multi-channel FFT Measurements | For frequency domain measurements that require you to see more than 500 MHz of signal spectral bandwidth and multiple FFTs simultaneously, the V-Series offers wider bandwidth than spectrum analyzers and comes standard with 4 ports (channels) per instrument. The V-Series enables users to make wideband measurements up to 33 GHz and up to 16 simultaneous FFTs. You can analyze even higher bandwidth signals by combining the V-Series with a down converter circuit. |