配置型號包含以下特性:
Oscilloscope Probes20GHz <= 50GHz特性 | 參數 |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
The InfiniiMax III probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fidelity and accuracy. Four different InfiniiMax III probe amplifiers ranging from 16 GHz to 30 GHz are available for matching your probing solution to your performance and budget requirements. A proprietary 200 GHz fT InP (indium phosphide) IC process with backside ground vias and novel thick film technology is utilized for the InfiniiMax III probe system to accommodate your highest performance needs and is unmatched by any product in the market.
InfiniiMax III 探測系統提供最高的頻寬和極低的負載,從而將訊號保真度和精度提升到全新水平。四種不同的 InfiniiMax III 探頭放大器(頻率範圍為 16 GHz 至 30 GHz)可用於將您的探測解決方案與您的性能和預算要求相匹配。 InfiniiMax III 探頭系統採用專有的 200 GHz fT InP(磷化銦)IC 工藝,具有背面接地通孔和新穎的厚膜技術,可滿足您的最高性能需求,是市場上任何產品都無法比擬的。
Key Features |
Full 30 GHz to the probe tip (with the N5445A browser) |
Industry’s lowest probe and scope system noise |
Industry’s highest fidelity and accuracy due to bandwidth and extremely low loading |
Probe amplifiers loaded with measured s-parameters for more accurate response correction |
Probe bandwidth upgradable |
Variety of probe heads for different use models with maximum usability |
Specifications | |
N2803A InfiniiMax III Series Probe Amplifier | |
Feature | Parameter |
Bandwidth | 30 GHz Tr = 14.3 psec |
Range | DC attenuation ratio: 6:1 (3:1 with 200 Ω ZIF tip) Input voltage range: 1.6 Vpp (0.8 Vpp with 200 Ω ZIF tip) Input common mode range: ±12 V at DC to 250 Hz, ±2.5 V at >250 Hz (±6 V at DC to 250 Hz, ±1.25 V at >250 Hz with 200 Ω ZIF tip) Offset range : ±16 V when probing a single-ended signal |
Input Impedance | DC input resistance: R diff = 100 kΩ ±2%, R se = 50 kΩ ±2% Input resistance @ >10 kHz: R diff = 1 kΩ, R se = 500 Ω Input capacitance: C diff = 32 fF, C se = 48 fF (with ZIF probe head) |
Recommended Probe Heads | N5445A 30 GHz Browser Probe Head N5444A 30 GHz 2.92/3.4 mm SMA Probe Head N5439A 28 GHz ZIF probe Head MX0109A 26 GHz Solder-in Probe Head |
Oscilloscope Connectivity | UXR 3.5mm oscilloscope UXR 1&1.85mm oscilloscope with N2852A adapter 90000X, Q, V, Z-series oscilloscopes |
Specifications | ||
InfiniiMax III Series Probe Amplifier | ||
Model Overview | ||
Model | Description | Recommended Oscilloscope |
N2800A | 16 GHz InfiniiMax III probe amplifier | Infiniium 90000X Series 16 GHz models |
N2801A | 20 GHz InfiniiMax III probe amplifier | Infiniium 90000X/Q Series 20 GHz models |
N2802A | 25 GHz InfiniiMax III probe amplifier | Infiniium 90000X/Q Series 25 GHz models |
N2803A | 30 GHz InfiniiMax III probe amplifier | Infiniium 90000X/Q Series 28 GHz - 63 GHz models |