配置型號包含以下特性:
Network & Fiber InstallationsOptical Time Domain ReflectometersHandheldModular特性 | 參數 |
---|---|
Form Factor | Handheld |
Form Factor | Modular |
High-resolution OTDR designed for metro networks testing and splitter characterization in PON FTTx applications.
Key Features |
Dynamic range of up to 42 dB |
Event dead zone of 0.5 m and attenuation dead zone of 2.5 m |
Test through high-port-count splitters (up to 1x128) |
Singlemode port for in-service troubleshooting with in-line 1490/1550 nm power meter |
EXFO Connect-compatible: automated asset management; data goes through the cloud and into a dynamic database |
iOLM-ready: one-touch multiple acquisitions, with clear go/no-go results presented in a straightforward visual format |
Applications |
FTTx/MDU test challenges within PON networks |
Metro/core network testing (P2P) |
Specifications | |
FTB-735C Metro/PON FTTx/MDU OTDR | |
Model Overview | |
Model | Description |
FTB-735C | OTDR |
Optical Configuration (FTB-735C-XX) | |
SM1 | SM OTDR module, 1310/1550 nm |
SM2 | SM OTDR module, 1310/1550 nm and 1625 nm live¹ |
SM3 | SM OTDR module, 1310/1550/1625 nm |
SM4 | SM OTDR module, 1310/1490/1550 nm |
OPM Option² (FTB-735C-XX-XX) | |
OPM | In-line power meter, one broadband channel (included) |
OPM2 | In-line power meter, dual channel 1490/1550 nm |
Base Software (FTB-735C-XX-XX-XX) | |
OTDR | Enables OTDR application only |
iOLM | Enables iOLM application only |
Oi | Enables OTDR and iOLM applications |
Singlemode Connector (FTB-735C-XX-XX-XX-XX) | |
EA-EUI-28 | APC/DIN 47256 |
EA-EUI-89 | APC/FC narrow key |
EA-EUI-91 | APC/SC |
EA-EUI-95 | APC/E-2000 |
EA-EUI-98 | APC/LC |
iOLM Software Option³ (FTB-735C-XX-XX-XX-XX-XX) | |
00 | iOLM standard |
iADV | iOLM advanced |
iPRO | iOLM pro |
iCERT | iOLM tier-2 certification |
Notes:
¹ The two ports are configured with the same adapter.
² Available with SM2 model only.
³ Please refer to the intelligent Optical Link Mapper (iOLM) specification sheet for the complete and most recent description of these value packs.
EI Connectors |
To maximize the performance of your OTDR, EXFO recommends using APC connectors on singlemode port. These connectors generate lower reflectance, which is a critical parameter that affects performance, particularly dead zones. APC connectors provide better performances than UPC connectors, thereby improving testing efficiency. Note: UPC connectors are also available, simply replace EA-XX by EI-XX in the ordering part number. Additional connector available: EI-EUI-90 (UPC/ST). |