配置型號包含以下特性:
Network & Fiber InstallationsOptical Time Domain ReflectometersMedium Range: 34dB - 37dBSinglemode (SM)HandheldModular特性 | 參數 |
---|---|
Dynamic Range (range) | Medium Range: 34dB - 37dB |
Fiber Mode | Singlemode (SM) |
Form Factor | Handheld |
Form Factor | Modular |
FTB-720C - LAN/WAN access OTDR
The ideal construction OTDR for everyday field testing in any access network. With an iOLM application for both singlemode and multimode testing, it’s the most automated and intelligent troubleshooting tool for FTTA, LAN and data centers.
Key Features |
Dynamic range of up to 36 dB in singlemode |
Event dead zone as low as 0.7 m and attenuation dead zone of 3 m |
Live fiber testing at 1625 nm |
Combined singlemode/multimode wavelengths |
Encircled Flux (EF) ready: use with external launch mode conditioner for EF-compliant multimode results |
iOLM-ready: one-touch multiple acquisitions, with clear go/no-go results presented in a straightforward visual format |
Specifications | |
FTB-720C LAN/WAN Access OTDR | |
Model | Description |
FTB-720C | OTDR |
Optical Configuration (FTB-720C-XX) | |
SM1 | SM OTDR, 1310/1550 nm |
SM2 | SM OTDR, 1310/1550 nm and 1625 nm live (a) |
Q1 | MM OTDR, 850/1300 nm. QUAD-ready (a) |
Q1-QUAD | QUAD OTDR, 850/1300 nm and 1310/1550 nm |
Base Software (FTB-720C-XX-XX) | |
OTDR | Enables OTDR application only |
iOLM | Enables iOLM application only |
Oi | Enables OTDR and iOLM applications |
Singlemode and Multimode Connector (c) (FTB-720C-XX-XX-XX) | |
EA-EUI-28 | APC/DIN 47256 |
EA-EUI-89 | APC/FC narrow key |
EA-EUI-91 | APC/SC |
EA-EUI-95 | APC/E-2000 |
EA-EUI-98 | APC/LC |
EI-EUI-28 | UPC/DIN 47256 |
EI-EUI-89 | UPC/FC narrow key |
EI-EUI-90 | UPC/ST |
EI-EUI-91 | UPC/SC |
EI-EUI-95 | UPC/E-2000 |
EI-EUI-98 | UPC/LC |
iOLM Software Option (b) (FTB-720C-XX-XX-XX-XX) | |
00 | iOLM Standard |
iADV | iOLM Advanced |
iPRO | iOLM Pro |
iLOOP | iOLM loopback mode |
iCERT | iOLM tier-2 certification |
Notes:
(a) The two ports are configured with the same adapter.
(b) Please refer to the iOLM specification sheet for the complete and most recent description of these value packs.
(c) Multimode connectors available in EI (UPC) only.
EI Connectors |
To maximize the performance of your OTDR, EXFO recommends using APC connectors on singlemode port. These connectors generate lower reflectance, which is a critical parameter that affects performance, particularly in dead zones. APC connectors provide better performance than UPC connectors, thereby improving testing efficiency. For best results, APC connectors are mandatory with the iOLM application. Note: UPC connectors are also available. Simply replace EA-XX by EI-XX in the ordering part number. Additional connector available: EI-EUI-90 (UPC/ST). |