配置型號包含以下特性:
Network & Fiber InstallationsOptical Spectrum AnalyzersBenchtop特性 | 參數 |
---|---|
Form Factor | Benchtop |
The MS9740A is a benchtop optical spectrum analyzer covering 600 nm to 1750 nm. The MS9740A offers high-performance optical resolution and high-speed measurements to support the needs of device and component manufacturers.
Waveform data can be measured and transmitted to external control equipment within 0.2s -- a 5x improvement over previous Anritsu models.
The Optical Spectrum Analyzer MS9740A reduces the total time from waveform sweeping to data transfer to external control equipment and supports simple analysis procedures, offering excellent cost performance and better productivity.
Key Features |
Measurement of passive optical devices in <0.2s(5nm) reduces total analysis time |
Dedicated applications for evaluating active optical devices |
Excellent cost performance |
Dynamic range performance ≥60 dB (0.4 nm from peak wavelength) |
30 pm minimum resolution bandwidth |
Supports SM and MM fibers |
Lightweight, 50% less power consumption |
Specifications | ||
Optical Spectrum Analyzer (OSA) | ||
Model | MS9740A | MS9740A-009 |
Applicable Optical Fiber | 10 μm/125 μm SM fiber (ITU-T G.652), 50 μm/125 μm GI fiber | 10 μm/125 μm SM fiber (ITU-T G.652), 50 μm/125 μm GI fiber, 62.5 μm/125 μm GI fiber |
Optical Connector | User replaceable: FC, SC, ST, DIN | User replaceable: FC, SC, ST, DIN |
Wavelength Measurement Range | 600 nm to 1750 nm | 600 nm to 1750 nm |
Wavelength Accuracy | ±20 pm (1520 nm to 1620 nm, Resolution: 0.03 to 0.2 nm)*1, *2 ±100 pm (1520 nm to 1620 nm, Resolution: 0.5, 1.0 nm)*1, *2 | ±50 pm (1530 nm to 1570 nm, Resolution: 0.07 to 0.2 nm)*3, *4 ±100 pm (1530 nm to 1570 nm, Resolution: 0.5, 1.0 nm)*3, *4 |
Setting Resolution | 0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0 nm (RBW: 3 dB optical filter: transmission bandwidth) | 0.07, 0.1, 0.2, 0.5, 1.0 nm (RBW: 3 dB optical filter: transmission bandwidth) |
Maximum Input power | +23 dBm (Optical ATT: On) | +23 dBm (Optical ATT: On) |
Dynamic Range | High dynamic range: 60 dB (0.4 nm from peak wavelength)*1 Normal dynamic range: 58 dB (0.4 nm from peak wavelength)*1 [Resolution: 0.05 nm, 1550 nm, Optical ATT: Off, 20° to 30°C] | High dynamic range: 60 dB (0.5 nm from peak wavelength)*3 Normal dynamic range: 58 dB (0.5 nm from peak wavelength)*3 [Resolution: 0.07 nm, 1550 nm, using SM fiber, Optical ATT: Off, 20° to 30°C] |
Sweep | Sweep width: 0.2 nm to 1200 nm, 0 nm Sweep speed: ≤0.2 sec. (Span 5 nm) [Resolution: 0.1 nm, VBW=10 kHz, Normal dynamic range, center 1550 nm, sweep start to stop, no optical input, sampling point: ≤501] | Sweep width: 0.2 nm to 1200 nm, 0 nm Sweep speed: ≤0.2 sec. (Span 5 nm) [Resolution: 0.1 nm, VBW=10 kHz, Normal dynamic range, center 1550 nm, sweep start to stop, no optical input, sampling point: ≤501] |
Dimensions and Mass | 426 (W) × 177 (H) × 350 (D) mm (excluding projections) ≤15.0 kg (without option) | 426 (W) × 177 (H) × 350 (D) mm (excluding projections) ≤15.0 kg (without option) |
Notes:
*1: Using SM fiber (ITU-T G.652), after 2 hours of warm-up (the Repeat sweeping performed at Span 100 nm or more and VBW 10 kHz or more during the warm-up operation), after Auto Align, at stable room temperature.
*2: Built-in option 002, after Wl cal (ref) wavelength calibration execution, at stable room temperature.
*3: Warm-up the instrument for at least 2 hours before measurement by performing repeated sweeping at span ≥100 nm, VBW = 10 kHz. Perform waveform calibration after auto-optical alignment (WI Cal) and keep the instrument at the same temperature unless stated otherwise. Use either SM fiber (ITU-T G.652) or GI fiber (50 μm/125 μm) with a return loss of >40 dB, or GI fiber (62.5 μm/125 μm) with a return loss of >38 dB.
*4: Built-in MS9740A-002, after Wl Cal (Ref), with SM fiber.