配置型號包含以下特性:
Network & Fiber InstallationsFiber Characterization / PMD / CMDHandheldModular特性 | 參數 |
---|---|
Form Factor | Handheld |
Form Factor | Modular |
FTB-5800 - chromatic dispersion analyzer delivers fast and reliable performance in a field-ready unit for all chromatic and polarization dispersion testing needs, from verifying the capacity of legacy fiber to upgrading a network to a given rate.
Designed for ultra-longhaul and 40/100 Gbit/s applications, EXFO’s FTB-5500B PMD and FTB-5800 CD analyzer combo provides you with the speed, accuracy and high performance you need to ensure high-quality network services. Housed in the expert FTB-500 platform, the FTB-5500B and FTB-5800 test modules survive splashes, knocks and drops—ideal for CO and field conditions.
Chromatic dispersion (CD) causes pulse broadening and can have a very negative impact on transmission performance by increasing the Bit Error Rate. EXFO’s FTB-5800 CD Analyzer offers high performance in a field-ready unit for all chromatic dispersion testing situations.
Key Features |
Complete CD characterization |
Highly accurate phase-shift method |
No communication between source and receiver |
Compliant with TIA-FOTP-169 standard |
Patented design: test through EDFAs |
100 Gbit/s-ready |
Benefits | |
Combining CD and PMD for Precise Link Characterization | Designed for ultra-longhaul and 40/100 Gbit/s (and higher) applications, EXFO’s FTB-5500B PMD and FTB-5800 CD analyzer combo provides you with the speed, accuracy and high performance you need to ensure high-quality network services. Housed in the expert FTB-500 platform, the FTB-5500B and FTB-5800 test modules survive splashes, knocks and drops—ideal for CO and field conditions. |
Measuring PMD the Fast Way | PMD represents a significant danger to both legacy and newly deployed networks because high PMD can induce bit error rate (BER). EXFO’s FTB-5500B PMD analyzer helps you get ahead in the field. Whether you need to verify the capacity of legacy fiber or upgrade a network to any speed, the modular FTB-5500B is fast, reliable and ready to go. |
Characterizing CD in the Field | CD causes pulse broadening and can have a very negative impact on transmission performance by increasing the BER. EXFO’s FTB-5800 CD analyzer offers high performance in a field ready unit for all CD testing situations. |
Specifications | |
FTB-5800 CD Analyzer | |
Feature | Parameter |
Wavelength Range (nm) | 1530 to 1625 1200 to 1700 b |
Wavelength Step (nm) | Minimum: 0.1 |
Measurement Points | Maximum: 950, user-definable |
Dynamic Range c (dB) | 42 |
Wavelength Uncertainty d (accuracy) (nm) | 0.1 |
Dispersion Uncertainty d (accuracy) (ps/nm) | 20 km of G.652: 1.6 120 km of G.652: 3.1 20 km of G.655: 1.9 (guaranteed) |
Dispersion Repeatability d (ps/nm) | 20 km: 0.04 80 km: 0.2 120 km: 1.1 |
Zero-Dispersion Wavelength λ0 Repeatability d (nm) | 20 km: 0.1 80 km: 0.14 120 km: 0.8 |
Dispersion Slope Repeatability λ0 d (%) | 20 km: 0.03 80 km: 0.05 120 km: 0.25 |
Minimum Fiber Length (km) | < 1 |
Maximum Fiber Length e (km) | > 5400 |
Measurement Time Per Point e (s) | < 1 |
Size (H x W x D) | 96 mm x 100 mm x 260 mm 3 ¾ in x 4 in x 10 ¼ in |
Weight | 2 kg 4.5 lb |
Operating Temperature | 0 °C to 40 °C 32 °F to 104 °F |
Storage Temperature | -20 °C to 50 °C -4 °F to 122 °F |
Relative Humidity | 0 % to 90 % non-condensing |
Note:
a. All specifications are typical with four seconds averaging time per point (where applicable), at a temperature of 23 ºC ± 1 ºC, with FC connectors and after warmup time.
b. Displayed range. Values may be extrapolated.
c. Dynamic range is defined as the difference between the strongest signal and the weakest detectable by the receiver. Extra averaging may be required. Uncertainty (accuracy) is not guaranteed at the limits of range.
d. C+L band.
e. Including EDFAs.
f. Additional gain setting time may be required prior to the first point of each band.
Specifications | |
FTB-5800 CD Analyzer | |
Model Overview | |
Model | Description |
Connector (FTB-5800-XX) | |
EI-EUI-28 | UPC/DIN 47256 |
EI-EUI-76 | UPC/HMS-10/AG |
EI-EUI-89 | UPC/FC narrow key |
EI-EUI-90 | UPC/ST |
EI-EUI-91 | UPC/SC |
EI-EUI-95 | UPC/E-2000 |
EA-EUI-28 | APC/DIN 47256 |
EA-EUI-89 | APC/FC narrow key |
EA-EUI-91 | APC/SC |
EA-EUI-95 | APC/E-2000 |