You are browsing the TW site. Would you like to be redirected to another country or region to see content and products specific to your location?
US
配置型號包含以下特性:
LCR / Impedance AnalyzersLCR Meters1MHz <= 10MHz特性 | 參數 |
---|---|
High Frequency (range) | 1MHz <= 10MHz |
This test fixture has two spring-loaded insertion slots into which axial/radial lead type devices can be inserted. A shorting plate is included for short-circuit correction.
Specifications | |
LCX LCR Meter | |
Test Fixtures Overview | |
Features | Parameters |
LCX-Z1 Test fixture for axial/radial lead type devices | |
Measurable Components | resistors, coils or capacitors with axial or radial connecting wires |
Frequency Range | DC to 10 MHz |
DC bias | 0 V to 40 V |
Weight | approx. 200 g |
Kelvin clip lead | |
Measurable Components | resistors, coils or capacitors |
Frequency Range | DC to 100 kHz |
DC bias | 0 V to 40 V |
Weight | approx. 250 g |
Test fixture for SMD components | |
Measurable Components | SMD resistors, coils or capacitors |
Frequency Range | DC to 10 MHz |
DC bias | 0 V to 40 V |
Weight | approx. 325 g |
Test tweezers for SMD components | |
Measurable Components | SMD resistors, coils or capacitors |
Frequency Range | DC to 10 MHz |
DC bias | 0 V to 40 V |
Weight | approx. 280 g |
Transformer test cables | |
Measurable Components | transformers, transmitters |
Frequency Range | DC to 100 kHz |
DC bias | 0 V to 40 V |
Weight | approx. 260 g |
BNC extension | |
Frequency Range | DC to 1 MHz |
Length | 1 m |
Weight | approx. 300 g |
Specifications | ||
LCX LCR Meter | ||
Model Overview | ||
Model | Order Number | Description |
Base Unit | ||
LCX100 | 3629.8856.02 | LCR meter, 300 kHz |
LCX200 | 3629.8856.03 | LCR meter, 500 kHz |
Options | ||
LCX-K106 | 3630.1922.03 | Advanced analysis functions |
LCX-K107 | 3660.7741.03 | Digital I/O ports and binning function |
LCX-K108 | 3692.9791.03 | Extended bias functions |
LCX-K201 | 3630.1880.03 | Frequency upgrade to 1 MHz, for R&S®LCX200 |
LCX-K210 | 3630.1900.03 | Frequency upgrade to 10 MHz, for R&S®LCX200 |
NG-B105 | 5601.6000.02 | IEEE-488 (GPIB) interface, for R&S®NGP/LCX |
Test Fixtures | ||
LCX-Z1 | 3639.2296.02 | Test fixture for axial/radial lead type devices |
LCX-Z2 | 3638.6446.02 | Kelvin clip lead |
LCX-Z3 | 3639.2509.02 | Test fixture for SMD components |
LCX-Z4 | 3639.2515.02 | Test tweezers for SMD components |
LCX-Z5 | 3639.2521.02 | Transformer test cables |
LCX-Z11 | 3639.2538.02 | BNC extension, length: 1 m |
System Components | ||
ZZA-GE23 | 5601.4059.02 | 19" rack adapter, 2 HU |