The PTS-300 and PTS-300F are CE marked DC Hipots designed as a two-piece system with a small, portable controller and a single piece high voltage section housed in a fiberglass cylinder with a spinning output.
Key Features
Two range voltmeter and five range current meter
MΩ readings at any output voltage (w/analog meters)
Insulated return guard circuit to bypass stray leakage currents
Rugged case (field) with cushion grip handles and storage for leads
Internal discharge resistors to assist external bleed resistors
External safety interlock provision
Automatic transit protected meters rated 100 uA for durability
Benchtop or field controller available, analog or digital metering
Specifications
PTS-300 AND PTS-300F DC Hipots
Features
Parameters
Input:
PTS-300 – 120Vac, 50/60Hz, 15A
PTS-300 – 230Vac, 50/60Hz, 8A
Output:
0 – 300 kV DC @ 5 mA with field controller or @ 10 mA with benchtop controller
Polarity/Ripple:
Negative output, positive ground
Ripple 2% – 3% depending on model
Duty:
Continuous, capacitive charging
Voltmeter:
3.5″, scaled 0-120/300 kV DC ±2% F.S.
Current Meter:
3.5″, scaled 0-1.0 μA DC, ±2% F.S. with multipliers of x 1, x 10, x 100, x 1 k, x 10 k Guard/ground load return