The Tri-Phase is a true three-phase transformer turns-ratio tester designed to conform to the IEEE C57.12.90 measurement standard. The Tri-Phase generates and outputs a three-phase excitation test voltage to the three transformer primary windings. The induced three-phase secondary voltages are sensed, and the transformer turns-ratio is calculated. The Tri-Phase can measure turns-ratios from 0.8 to 15,000. The three-phase turns-ratios, excitation current, and phase angle readings are displayed on the unit’s LCD screen. Since a three-phase voltage is used to excite the transformer windings, the Tri-Phase can detect and measure turns-ratios of any transformer type, including phase-shifting transformers.
Key Features |
Generates 3-phase transformer test voltage from single-phase AC or DC power input |
Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards |
3 test voltages: 8Vac, 40Vac, and 100Vac |
RS-232C and USB PC interfaces |
Built-in 4.5” wide thermal printer |
Specifications | |
Tri-Phase True 3-Phase Transformer Turns Ratio Tester | |
Features | Parameters |
Dimensions | 21”W x 9”H x 17” D (53 cm x 24 cm x 43 cm) |
Weight | 35 lbs (15.8 Kg) |
Measuring Method | ANSI/IEEE C57.12.90 |
Typical Turns Ratio Accuracy | 8 Vac: 0.8 ¬ 1,000 (±0.08%), 1,001 ¬ 4,000 (±0.1%), 4,001 ¬ 15,000 (±0.25%) 40 Vac: 0.8 ¬ 1,000 (±0.05%), 1,001 ¬ 4,000 (±0.1%), 4,001 ¬ 15,000 (±0.2%) 100 Vac: 0.8 ¬ 1,000 (±0.05%), 1,001 ¬ 4,000 (±0.1%), 4,001 ¬ 15,000 (±0.2%) |
Test Voltages | Three-phase; 8 Vac @ 1 Amp 40 Vac @ 0.2 Amps 100 Vac @ 0.1 Amp |
Display | Back-lit LCD screen (128 x 64 pixels) Viewable in bright sunlight and low-light levels |
Printer | Built-in 4K” wide thermal printer |
PC Software | Windows®-based transformer turns-ratio analysis software is included with purchase |
Internal Test Record Storage | stores 112 complete transformer test records, each record holding the test record header and up to 99 readings |
Safety | designed to meet UL 61010A-1 and CAN/CSA C22.2 No. 1010.1-92 standards |
Temperature | Operating: -10°C to +50°C (+15°F to +122°F) Storage: -30°C to +70°C (-22°F to +158°F) |
Cables | 15-foot (4.57m) single-phase set 15-foot (4.57m) 3-phase set 25-foot (7.62m) extension set Safety ground power USB RS-232C Cable bag |
Options | shipping case, 30' (9.14 m) 3-phase H and X leads, 30' (9.14 m) single phase H and X leads |
Input Power | 100 ¬ 240 Vac, 50/60 Hz, 3 amps |
Ratio Measuring Range | 0.8 ¬ 15,000 : 1 (5-digit resolution) |
Current Reading Range | 0 ¬ 1 Ampere, accuracy: ±0.1mA, ±2% of reading (±1 mA) |
Phase Angle Measurement | 0 ¬ 360 degrees accuracy: ±0.2 degree (±1 digit) |
Computer Interfaces | One RS-232C port One USB port |
Internal Test Plan Storage | Stores up to 128 transformer test plans; plans can be transferred to PC. |
External Data Storage | Up to 999 test records on external USB flash drive (drive not included) |
Humidity | 90% RH @ 40°C (104°F) non-condensing |
Altitude | 2,000 m (6,562 ft) to full safety specifications |
ITC Contact | 240 Vac, 2A |
Note:
Specifications are valid at nominal voltage and ambient temperature of +25°C (+77°F).