配置型號包含以下特性:
Electrical & Power QualitySound / Vibration Analyzers請參考資源中的資料文檔或查看產品總覽。
如果您想瞭解更多,請 聯繫,我們的團隊將為您提供幫助。
The ii910 Precision Acoustic Imager, engineered to locate partial discharge, corona discharge as well as gas and vacuum leaks. The ii910 acoustic imaging camera's groundbreaking technology is a cost efficient, safe, effective, and comfortable tool for teams who inspect and maintain power distribution and industrial high voltage equipment.
Key Features |
Quick and easy partial discharge detection and PD testing |
Reduce outages and increase uptime |
Cut costs and save energy everyday by finding and fixing PD |
PDQ Mode to capture and analyze partial discharge |
Specifications | |
Fluke ii910 Precision Acoustic Imager | |
Features | Parameters |
Standard Palettes | 3: Grayscale, Ironbow, Blue-Red |
Operating Temperature | 0 °C to 40 °C (32 °F to 104 °F) |
Storage Temperature | -20 °C to 70 °C (-4 °F to 158 °F) Without batteries |
Relative Humidity | 10 % to 95 % non-condensing |
Size (H x W x L) | 186 x 322 x 68 mm (7.3 x 12.7 x 2.7 inches) |
Weight (battery included) | 2.15 kg (4.74 lbs) |
Ingress Protection (IP) | IP40 protection |
Warranty | 2 year |
Self-Diagnostic Notification | Array-health test to identify when microphone array needs attention |
Supported Languages | Dutch English Finish French German Italian Japanese Korean Polish Portuguese Russian Simplified Chinese Spanish Swedish Traditional Chinese |
RoHS Compliant | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | 2 x Rechargeable Li-ion, Fluke BP291 |
Battery Life | 6 hours/battery (product includes spare battery) |
Battery Charging Time | 3 hours |
Battery Charging System | External dual-bay charger, EDBC 290 |
Safety | |
General Safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Specifications | |
Fluke ii910 and ii900 Acoustic Imagers | |
Model Overview | |
Model | Description |
FLK-ii910 | Precision Acoustic Imager Includes: Imager AC power supply and battery pack charger (including universal AC adapters) Two rugged lithium ion smart battery packs USB Cable Rugged Hard Carrying Case Two Rubber Array Covers Adjustable Hand Strap Adjustable Neck Strap |
FLK-ii900 | Industrial Acoustic Imager Includes: Imager AC power supply and battery pack charger (including universal AC adapters) Two rugged lithium ion smart battery packs USB Cable Rugged Hard Carrying Case Two Rubber Array Covers Adjustable Hand Strap Adjustable Neck Strap |