The M8046A supports symbol rates up to 32 Gbaud and 64 Gbaud, the default is 32 Gbaud and NRZ format. The analyzer module can be used for error analysis in conjunction with the M8045A pattern generator and the M8195A/M8196A arbitrary waveform generator.
The M8046A is not a standalone model. It is part of a M8040A BERT system.
The Keysight M8040A is a highly integrated BERT for physical layer characterization and compliance testing. With support for PAM-4 and NRZ signals and data rates up to 64 GBaud (corresponds to 128 Gbit/s) it covers all flavors of 200 and 400 GbE standards.
The M8040A is designed for R&D and test engineers who characterize chips, devices, transceiver modules and sub-components, boards and systems with serial I/O ports operating with data rates up to 32 GBaud and 64 GBaud in the data center and communications industry.
The M8040A can be used for receiver (input) testing for many popular interconnect standards that use PAM-4 and NRZ data formats, such as: 400 GbE, 50/100/200 GbE, OIF CEI-56G and CEI-112G, 64G/112G Fibre Channel, Infiniband-HDR and proprietary interfaces for chip-to-chip, chip-to-module, backplanes, repeaters and active optical cables.
Key Features |
Data rates from 2 to 32 and 64 GBaud for pattern generator and analyzer |
PAM-4 and NRZ selectable from user interface |
Built-in de-emphasis with 4 taps |
Integrated and calibrated jitter injection: RJ, PJ1, PJ2, SJ, BUJ, and clk/2 jitter |
Two pattern generator channels per module to emulate aggressor lane |
Short connections to the DUT with remote heads for the pattern generator |
True PAM-4 error detection in real-time for low BER levels |
All options and modules are upgradeable |
The remote head M8057A is required for each channel and is required for NRZ and PAM-4 signals.It contains an adjustable gain amplifier without re-timer. Users can select NRZ or PAM-4 coding and de-emphasis taps settings from the user interface with no need to reconnect cables. The cable between the remote head and the module is 0.85 m long. This allows positioning the remote head closely to the test board for the device under test.
Specifications | |
J-Bert High-Performance BERT; 32/64 GBaud | |
Ordering Information | |
Model | Description |
M8040A-BU1 | Bundle consisting of one M9505A 5-slot AXIe Chassis and one M9537A AXIe Embedded PC Controller with 16GB RAM option |
M8040A-BU2 | Bundle consisting of one M9505A 5-slot AXIe Chassis |
M8040A-BU3 | Bundle consisting of one M9505A 5-slot AXIe Chassis and one M9537A AXIe Embedded PC Controller with 16GB RAM and Windows 10 Option |
Specifications | ||
M8040A High-Performance BERT 64 Gbaud | ||
Model/Module Options Overview | ||
Model | Option | Description |
M8040A | -- | High-performance BERT 64 Gbaud (systemizing number for factory pre-installation) |
Pattern Generator and Clock Module, 32/64 Gbaud, 3-Slot AXIe | ||
M8045A | G32 | Pattern generator one channel NRZ, data rate up to 32 Gbaud (requires remote head, M8057A/B) |
M8045A | G64 | Pattern generator one channel NRZ, data rate up to 64 Gbaud (requires remote head, M8057A/B) |
M8045A | 0G2 | Second channel, hardware and license (requires remote head, M8057A/B) |
M8045A | 0G3 | Advanced jitter sources for receiver characterization, module-wide license |
M8045A | 0G4 | De-emphasis, module-wide license |
M8045A | 0G6 | Reference clock multiplier, module-wide license |
M8045A | 0G9 | Forward Error Correction (FEC) encoding, module-wide license |
M8045A | 0P3 | PAM4 encoding up to 32 Gbaud, module-wide license |
M8045A | 0P6 Only with G64, 0P3/UP3 | Extension to PAM4 encoding up to 64 Gbaud, module-wide license |
M8045A | 801 Qty 2 recommended | Short cable 1.85 mm (m) to 1.85 mm (m), 0.15 m, absolute matching 699 ps ± 1 ps |
M8057A | -- | Remote head for M8045A pattern generator, 1 channe |
M8046A | -- | Analyzer Module, 32/64 Gbaud, 1-slot AXIe |
M8046A | A32 | Analyzer, one channel, data rate up to 32 Gbaud, NRZ |
M8046A | A64 | Analyzer, one channel, data rate up to 64 Gbaud, NRZ |
M8046A | 0A3 Only with A64 | Equalization, license (only needed for > 32 Gbaud) |
M8046A | 0P3 | PAM4 decoding up to 32 Gbaud, license |
M8046A | 0P6 Only with A64, 0P3, 0A3 | PAM4 decoding extension to 58 Gbaud, license |
M8046A | 0A4 | Clock recovery for 32 Gbaud, license |
M8046A | 0A5 Only with A64 and 0A4 | Clock recovery extension to 64 Gbaud, license |
M8046A | 0S1 Requires 0A4, 0G4 | Interactive link training for PCIe, license |
M8046A | 0S2 | SKP OS filtering for PCIe and CCIX, license |
M8046A | 0S3 Requires 0A4 | Interactive link training for USB 3.2, license |
M8046A | 0S4 Opt. 0A4 recommended | SKP OS filtering for USB 3.x, license |
M8046A | 0S6 Opt. 0A4 recommended | ALIGN filtering for SATA 3/6G, SAS 3/6/12G, license |
M8046A | 0N2 Opt. 0S2 required | PCIe Filtering of SKP OS Extension for 64 GT/s |
M8046A | 801 Qty 1 recommended | Cable 2.92 mm (m) to 2.92 mm (m), 0.5 m for clock input |
M8046A | 002 Qty 1 recommended | Matched cable pair 2.4 mm(m) to 2.4 mm (m) |
Software and Chassis | ||
M8070B | unlicensed | System software for M8000 Series |
M8070ADVB | 1FP/1TP/ 1NP/1UP ¹ | Advanced measurement package |
M8070EDAB | 1FP/1TP/ 1NP/1UP ¹ | Error distribution analysis package |
M8040A | BU2 | 5-slot AXIe chassis with USB option |
M8040A | BU3 | 5-slot AXIe chassis with USB option and embedded controller M9537A |
Note:
¹ Multiple types of licenses are available. Choose between 6/12/24 month support subscriptions.