Attribute | Value |
---|---|
High Frequency (range) | 85GHz < |
Channel/Port Count | 2 |
The ML2437A Power Meter combines the advantages of thermal meter accuracy, diode meter speed, and peak power meter display graphics. The result is a single instrument that samples at more than 35K per second and achieves 90 dB dynamic range with a single sensor. This meter includes graphics display capability as a standard feature. The ruggedized housing and optional high-capacity NiMH battery bring laboratory quality accuracy to field service applications. ML2438A has two inputs.
Key Features |
Speed and dynamic range |
Fast thermal sensors |
GPIB speed |
GPIB emulation |
Triggering controls |
Burst profile graphics display |
Power vs. time graphics display |
Parallel printer connector |
Benefits | |
90 dB Dynamic Range | Typical communications industry ATE systems operate over a 60 to 80 dB dynamic range. The MA247xD Series' 90 dB dynamic range replaces two 50 dB sensors. Further an RF switch is no longer needed for the two sensors. This reduces software control complexity and further speeds test execution. |
Sensor EEPROM | All MA24xx Series sensors are equipped with internal EEPROMs for storage of calibration factor data vs. frequency. This allos the power meter to interpolate and correct readings automatically, improving accuracy and convenience. |
High Reliability | Rugged poly-carbonate chassis design handles drop shocks and rough field treatment. No vent holes are present, thus the meter is splash resistant. A front cover panel and softcase are optional for further environmental protection. Power sensors are also ruggedized for rough handling. |
Improved Accuracy | Mismatch uncertainty is typically the largest source of error. The MA24xx Series Power Sensors offer a typical 5 to 6 dB improvement in sensor return loss, typically cutting mismatch uncertainty in half. The MA244xD series High Accuracy Sensors incorporate a matching pad which further improves return loss by 5 to 6 dB - again halving mismatch uncertainty. |
Offset Table for Path Loss Correction | Compensating for the true frequency response of attenuators, couplers, cables, switches and other test setup devices improves measurement accuracy. For this reason, the ML2430A Series can apply an offset table of attenuation-versus-frequency in addition to the traditional fixed dB offset capability. When a power sensor connection is preceded with a new 1N series wideband power limiter, the offset table compensates for frequency response. Thus, the combination achieves an accurate, “burnout-proof” sensor. |
Softkey Menu Control | Softkey menus simplify instrument control by making the user interface easier to understand. The numerical keypad simplifies the operator interface. |
Battery | The optional NiMH “Smart” battery supports high charge density for a typical 8 hour day of operation. Accurate fuel gauging, <2 hour fast charge cycling, and the elimination of NiCd style memory effect fur-ther enhances the convenience of this battery technology. |
Voltmeter | The ML2430A Series also supports high speed voltage measurement. A rear panel BNC measures voltage or operates as V/GHz input supporting automated sensor calibration factor correction. |
Specifications | |
Power Meters and Power Sensors | |
Model Overview | |
Model | Description |
Power Meter Models | |
ML2495A | Pulse Power Meter, Single Input |
ML2496A | Pulse Power Meter, Dual Input |
ML2437A | CW Power Meter, Single Input |
ML2438A | CW Power Meter, Dual Input |
Power Sensors | |
MA2472D | Standard Diode Sensor (10 MHz to 18 GHz, –70 dBm to 20 dBm) |
MA2473D | Standard Diode Sensor (10 MHz to 32 GHz, –70 dBm to 20 dBm) |
MA2474D | Standard Diode Sensor (10 MHz to 40 GHz, –70 dBm to 20 dBm) |
MA2475D | Standard Diode Sensor (10 MHz to 50 GHz, –70 dBm to 20 dBm) |
MA2442D | High-Accuracy Diode Sensor (10 MHz to 18 GHz, –67 dBm to 20 dBm) |
MA2444D | High-Accuracy Diode Sensor (10 MHz to 40 GHz, –67 dBm to 20 dBm) |
MA2445D | High-Accuracy Diode Sensor (10 MHz to 50 GHz, –67 dBm to 20 dBm) |
MA2481D | Universal Sensor (10 MHz to 6 GHz, –60 dBm to 20 dBm) |
MA2482D | Universal Sensor (10 MHz to 18 GHz, –60 dBm to 20 dBm) |
MA2490A | Wideband Sensor (50 MHz to 8 GHz, –60 dBm to 20 dBm) |
MA2491A | Wideband Sensor (50 MHz to 18 GHz, –60 dBm to 20 dBm) |
MA2411B | Pulse Sensor (300 MHz to 40 GHz, –20 dBm to 20 dBm) |
MA24002A | Thermal Sensor (10 MHz to 18 GHz, –30 dBm to 20 dBm) |
MA24004A | Thermal Sensor (10 MHz to 40 GHz, –30 dBm to 20 dBm) |
MA24005A | Thermal Sensor (10 MHz to 50 GHz, –30 dBm to 20 dBm) |