Specifications |
|
|
N9038B MXE EMI Test Receiver |
|
|
Option Overview |
|
|
Model / Option | Description | Additional Information |
N9038B-503 | Frequency range, 3 Hz to 3.6 GHz |
|
N9038B-508 | Frequency range, 3 Hz to 8.4 GHz |
|
N9038B-526 | Frequency range, 3 Hz to 26.5 GHz |
|
N9038B-544 | Frequency range, 3 Hz to 44 GHz |
|
Preamplifier Option |
|
|
N9038B-P03 | Preamplifier, 100 kHz to 3.6 GHz | Compatible with frequency range option N9038B-503 |
N9038B-P08 | Preamplifier, 100 kHz to 8.4 GHz | Compatible with frequency range option N9038B-508 |
N9038B-P26 | Preamplifier, 100 kHz to 26.5 GHz | Compatible with frequency range option N9038B-526 |
N9038B-P44 | Preamplifier, 100 kHz to 44 GHz | Compatible with frequency range option N9038B-544 |
Frequency Reference |
|
|
Standard | Frequency reference | Aging rate: ± 1 x 10⁻⁶/year |
N9038B-PFR | Precision frequency reference | Reduces frequency drift for more accurate measurements Aging rate: ± 1 x 10⁻⁷/year |
Analysis Bandwidth |
|
|
Standard | 10 MHz analysis bandwidth |
|
N9038B-B25 | 25 MHz analysis bandwidth | Extends the analysis bandwidth to 25 MHz |
N9038B-B85 | 85 MHz analysis bandwidth | Extends the analysis bandwidth to 85 MHz, below 3.6 GHz |
N9038B-B1X | 160 MHz analysis bandwidth | Extends the analysis bandwidth to 160 MHz, below 3.6 GHz |
Performance Options |
|
|
Standard | Digital processor with 2 GB capture memory | Licensed as N9038B-DP2 |
Standard | Noise floor extension | Improves displayed average noise level (instrument alignment based processes);
licensed as N9038B-NFE
|
Standard | Enhance display package | Includes spectrogram, trace zoom, and zone span;
licensed as N90E1EDPB
|
N9038B-CNF | Type-N RF connector, female | Choose Type-N RF connector for Input 1 |
N9038B-C35 | APC 3.5 mm connector, male | Choose 3.5 mm connector for Input 1 (Input 2 remains type-N); compatible with Option 526 only |
N9038B-EXM | External mixing | Provides external mixing with Keysight and third party mixers; single port for LO out and IF in (SMA female) |
N9038B-ESC | External source control | Controls EXG, MXG and PSG sources from the front panel of the MXE |
Rear Panel Output Utilities |
|
|
N9038B-CR3 | Wideband IF output | Wideband IF out; center frequency depends on IF path; output on Aux IF connector at rear panel |
N9038B-YAS | Y-axis screen video output | Screen video (0-1 volt open circuit) on rear panel analog out |
Security Features |
|
|
N9038B-SS2 | Additional removable solid-state drive (SSD) | Provides a fully-imaged, removable SSD in addition to the one installed in instruments, with Windows 10 operating system |
N9038B-SF1 | Exclude launch program | Prevents the launching of Windows programs from the instrument application |
N9038B-SF2 | Prohibit saving results | Prevents the saving/recall of measurement results or user configurations to/from instrument's data storage |