The S93089B combines source-phase control of multiple internal or external sources with frequency-offset mode, enabling simplified test of I/Q modulators/converters and differential mixers, and harmonic measurements of differential amplifiers. The phase difference between sources can be fixed (for example, at 90 or 180 degrees), or swept between two specified phase values. Providing accurate control of the relative phase between sources eliminates the need for hybrid couplers and baluns to create quadrature or differential signals.
After achieving the desired phase alignment, the instrument's receivers can be tuned to all frequencies needed to characterize the DUT. On an I/Q modulator for example, measurements can be made of both the desired and suppressed conversion bands, along with LO leakage, harmonics and other spurious signals. Phase sweeps can be used to determine a DUT’s phase imbalance versus frequency.
Users can specify measurements with individual receivers or multiple receivers combined with a wide range of mathematical operators. Power measurements can employ match correction for increased accuracy.
The S93089B is equivalent to Option 089 on the PNA Series A models and only works on 4-port PNA or PNA-X models.
Key Features |
Accurately control the phase of multiple signal sources for quadrature or differential drive, eliminating the need for hybrid couplers and baluns |
Tune receivers to all output frequencies required to fully characterize the DUT |
Sweep frequency with a fixed phase offset, or sweep phase or power at a fixed frequency |
Easily measure I/Q converters/modulators, differential mixers, or harmonics of differential amplifiers |
S93089B only works on 4-port PNA or PNA-X models |
Specifications | ||
Application Software⁸ | ||
Software Overview | ||
Application Software⁸ | Description | Additional Information |
S93007B | Automatic fixture removal | -- |
S93010B | Time domain analysis | -- |
S93011B | Enhanced Time Domain Analysis with TDR | Provides TDR measurement class. S93010B is a subset of S93011B. |
S93015B | Real time S-parameter and power measurement uncertainty | Displays the measurement uncertainty dynamically (real-time) on the measurement trace |
S93025B | Basic pulsed-RF measurements | Includes control of internal pulse generators and provides pulse widths to 200 ns using wideband detection |
S93026B | Advanced pulsed-RF measurements | Includes control of internal pulse generators and provides pulse widths to 100 ns using wideband detection, and 20 ns using narrowband detection. |
S93027B⁸ | Add mechanical noise tuner control for noise figure/ parameter measurements | Provides ability to control Maury Microwave's LXI impedance tuners. Requires application software S93029B |
S93029B | Noise figure measurements with vector correction² | Standard receivers are used if hardware option N524xB-029 is not present |
S930317B | Phase noise measurement up to 70 GHz | Direct Digital Synthesizer (DDS) source is required. (S/N prefix 6021 or after, or upgraded unit with N52xxBU-2S7 or 4S7) |
S930321B | Phase noise measurement up to 125 GHz | This is for N5290A/91A or N5292A with N5293AX/95AX frequency extenders configuration. Direct Digital Synthesizer (DDS) source is required on PNA/ PNA-X (S/N prefix 6021 or after, or upgraded unit with N52xxBU-2S7 or 4S7) |
S930700B⁸ | Modulation distortion, up to 8.5 GHz | Requires test set option 22x or 42x |
S930701B⁸ | Modulation distortion, up to 13.5 GHz | Requires test set option 22x or 42x |
S930702B⁸ | Modulation distortion, up to 26.5 GHz | Requires test set option 22x or 42x |
S930704B⁸ | Modulation distortion, up to 43.5 GHz | Requires test set option 22x or 42x |
S930705B⁸ | Modulation distortion, up to 50 GHz | Requires test set option 22x or 42x |
S930707B⁸ | Modulation distortion, up to 70 GHz | Requires test set option 22x or 42x |
S93080B | Frequency-offset measurements | Provides ability to independently set the frequency of internal sources and receivers, and to configure external sources. This functionality is included withS93029/082/083/084/086/087/089/090x/093/094B |
S93082B | Scalar mixer/converter measurements | Provides SMC measurement class. S93082B is a subset of S93083B. |
S93083B | Vector and scalar mixer/converter measurements³ | Provides SMC+Phase and VMC measurement classes |
S93084B | Embedded-LO capability | Works with S93029/082/083/086/087B |
S93086B | Gain-compression measurements | -- |
S93087B | Intermodulation distortion measurements⁴ | -- |
S93088B | Source phase control | -- |
S93089B | Differential and I/Q device measurements | Requires a 4-port test set option (4xx) |
S930900B | Spectrum analysis, up to 8.5 GHz⁵ | -- |
S930901B | Spectrum analysis, up to 13.5 GHz⁵ | -- |
S930902B | Spectrum analysis, up to 26.5 GHz ⁵ | -- |
S930904B | Spectrum analysis, up to 43.5 GHz⁵ | -- |
S930905B | Spectrum analysis, up to 50 GHz⁵ | -- |
S930907B | Spectrum analysis, up to 70 GHz⁵ | -- |
S930909B | Spectrum analysis, up to 90 GHz⁵ | -- |
S93093B | Spectrum analysis, up to 120 GHz | -- |
S93094B | Spectrum analysis, beyond 120 GHz | -- |
S93110B⁸ | Active hot parameters | Export-controlled |
S93111B⁸ | Active hot parameters | Function-restricted version. The maximum operation is 50 GHz with N5247B |
S93118B | Fast CW measurements | -- |
S93460B | True-mode stimulus | Requires a 4-port test set option (4xx) |
S93551B | N-port measurements⁶ ⁷ | -- |
S94601B | Device measurement expert (DMX) | -- |
S94602B | Limit assistant | -- |
Note:
¹ Supported software license types: fixed-perpetual (1FP), transportable-perpetual (1TP), fixed-1-year (1FY), and transportable1-year (1TY) (note: S93093B, S93094B, S93898B, and S94510B have fixed-license types only).
² For N522xB and N5241/42/49B, vector-noise-corrected measurements require an ECal for use as an impedance tuner. For N5244/45/47B with Option 029, an internal tuner is included. Noise calibration requires a power meter when using a standard receiver. When using the low-noise receiver (Option 029), either a power meter or a 346-series noise source is required (Keysight 346C or 346C-K01 recommended). A power meter is required for measuring mixers and converters.
³ A configurable test set is required for VMC measurements to connect a reference mixer, or for SMC+Phase measurements using the comb-generator-based calibration. When ordered with PNA test set Options 200, 210, 400, or 410 (no front-panel jumpers), phase and delay measurements can only by done using SMC+Phase with a calibration mixer.
⁴ S93087B can be used without PNA-X Options 22x or 42x, but external equipment such as a signal generator and a combiner may be required.
⁵ A test set with internal receiver attenuators is recommended to avoid receiver compression when measuring large input signals.
⁶ When ordering a test set, select an appropriate interface kit.
⁷ When configured as a multiport analyzer using S93551B and a multiport test set, the combiner feature of Option 22x or 42x is temporarily disabled. When configured as a standalone analyzer, the combiner feature is enabled.
⁸ PNA-X models only.