Configured models contain the following attributes:
Oscilloscopes & Logic AnalyzersOscilloscopes < 1GHzPlease use 'Get Quick Quote' or ‘Configure Unit’ and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
MSO/DPO5000B Series oscilloscopes, designed for engineers debugging and verifying complex systems, provide exceptional signal fidelity, and advanced analysis and math capabilities, for your bench or for your lab. MSO models include 16 digital timing channels and all models can be equipped to decode common serial protocols—providing a comprehensive view of your systems
Leading performance and analysis for more advanced design verification.
Designing with today’s faster data rates and tighter timing margins requires an oscilloscope with outstanding signal acquisition performance and analysis capabilities. Tektronix MSO/DPO5000B Series oscilloscopes provide exceptional signal fidelity, with 2 GHz and 10 GS/s sample rate, along with advanced analysis and math capabilities, for your bench or for your lab. Run Windows®-based analysis software right on the oscilloscope. MSO models include 16 digital timing channels, and all models can be equipped to decode common serial protocols, to provide a comprehensive view of your systems.
Key Performance Specifications |
2 GHz, 1 GHz, 500 MHz, and 350 MHz bandwidth models |
Up to 10 GS/s real-time sample rate on one or two channels and up to 5 GS/s on all four channels |
Up to 250 Megapoint record length with MultiView zoom™ |
>250,000 wfms/s maximum waveform capture rate with FastAcq® acquisition |
FastFrame™ segmented memory acquisition mode with up to 290,000 segments and >310,000 waveforms per second capture rate |
Standard 10 MΩ passive voltage probes with less than 4 pF capacitive loading and 500 MHz or 1 GHz analog bandwidth |
>11 bits vertical resolution using HiRes sampling |
User-selectable bandwidth limit and DSP filters for lower noise and better measurement accuracy |
Key Analysis Features |
Wave inspector® controls provide easy navigation and automated search of waveform data |
Suite of advanced triggers, with standard Visual Trigger and Search |
53 automated measurements, selectable filtering, waveform math and FFT analysis |
Waveform histogram, eye diagram, TIE (jitter/timing) measurement and analysis |
User-definable math using MATLAB, Visual Studio and Excel |
Optional analysis for memory, advanced jitter, serial data, power and Wideband RF |
Key Protocol Features |
Trigger and decode options for mid-speed (100 Mb/s to 1 Gb/s) buses |
Trigger and decode options for low-speed (<10 Mb/s) buses |
Compliance test options for USB2.0, Ethernet, USB power, MOST, and Automotive Ethernet |
Mask testing on communication, computing and video standards |
Specifications | ||||
MSO/DPO5000B Series Mixed Signal Oscilloscopes | ||||
Model | MSO5034B DPO5034B | MSO5054B DPO5054B | MSO5104B DPO5104B | MSO5204B DPO5204B |
Input Channels | 4 | 4 | 4 | 4 |
Bandwidth | 350 MHz | 500 MHz | 1 GHz | 2 GHz |
Rise Time (Calculated) | 1 ns | 700 ps | 350 ps | 175 ps |
DC Gain Accuracy | ±1.5%, derated at 0.10%/°C above 30 °C | ±1.5%, derated at 0.10%/°C above 30 °C | ±1.5%, derated at 0.10%/°C above 30 °C | ±1.5%, derated at 0.10%/°C above 30 °C |
Bandwidth Limits | Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz | Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz | Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz | Depending on instrument model: 1 GHz, 500 MHz, 350 MHz, 250 MHz, 20 MHz |
Effective Number of Bits (Typical) | 6 bits (10 divisionp-p sine wave input at instrument bandwidth, 100 mV/div, 50 Ω Input Impedance, maximum sample rate, 1 k point record length) | 6 bits (10 divisionp-p sine wave input at instrument bandwidth, 100 mV/div, 50 Ω Input Impedance, maximum sample rate, 1 k point record length) | 6 bits (10 divisionp-p sine wave input at instrument bandwidth, 100 mV/div, 50 Ω Input Impedance, maximum sample rate, 1 k point record length) | 6 bits (10 divisionp-p sine wave input at instrument bandwidth, 100 mV/div, 50 Ω Input Impedance, maximum sample rate, 1 k point record length) |
Specifications | |
MSO/DPO5000B Series | |
Model Overview | |
Model | Description |
DPO5000B Series | |
DPO5034B | 350 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscope |
DPO5054B | 500 MHz, 5 GS/s, 25 M record length, 4-channel digital phosphor oscilloscope |
DPO5104B | 1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscope |
DPO5204B | 2 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4-channel digital phosphor oscilloscope |
MSO5000B Series | |
MSO5034B | 350 MHz, 5 GS/s, 25 M record length, 4+16 channel mixed signal oscilloscope |
MSO5054B | 500 MHz, 5 GS/s, 25 M record length, 4+16 channel mixed signal oscilloscope |
MSO5104B | 1 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4+16 channel mixed signal oscilloscope |
MSO5204B | 2 GHz, 10/5 GS/s (2/4 ch), 50 M/25 M record length, 4+16 channel mixed signal oscilloscope |