You are browsing the NO site. Would you like to be redirected to another country or region to see content and products specific to your location?
US
Configured models contain the following attributes:
Electrical & Power QualityPower Analysis / Recorders / LoggersPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
Record three-phase power quality and monitor for power quality disturbances with the Fluke 1750 Power Recorder and the Fluke Power Analyze software. These power meters automatically record every power quality parameter and event, on every cycle – all the time.
Key Features | |
Power quality that meets the standard: | All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc. |
Ethernet interface: | Included Windows 10 tablet allows for quick setup and verification with waveform displays, meter screens, and phasor diagrams. |
Quick and reliable configuration: | Windows 10 tablet “front panel interface” provides the ability to verify setup without a laptop along with a window into what the instrument is recording. |
Threshold-free setup: | Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to worry about missed information due to incorrect set-up. |
Captures everything: | Cross-channel and current triggering capture every measurement, on every channel, every time. |
Intuitive PC software: | Easily analyze data and generate reports. Automated EN50160 reporting and compliance running directly on the supplied Windows 10 tablet. |
Plug and play: | Set up in minutes with self-identifying current probes and single-lead voltage connections. |
No need to reconnect wires: | Swap channels internally with the Windows 10 front panel or PC when connections are not correct. |
Measure every parameter: | voltage and current on three phases, neutral, and ground. |
5 MHz, 8000 Vpk waveform capture: | Get a detailed picture of even the shortest events. |
Quickly retrieve data: | With included SD memory card or via the 100BaseT ethernet connection. |
General Specifications | |
Power quality measurement standards | |
Conformance | IEC 61999-1-4 Class 1, IEC 61000-4-30 (Class A or Class S depending on measurement function), IEEE519, IEEE1159, IEEE1459 and EN50160 |
Clock/calendar | Leap years, 24-hour clock |
Real-time clock accuracy | Not more than ± 1 s/day |
Internal memory capacity for data | At least 2 GB |
Maximum recording period | At least 31 days |
Measurement time control | Automatic |
Maximum number of events | Limited only by the size of the internal memory |
Power requirements | 100 to 240 V rms ± 10 %, 47-63 Hz, 40 W |
Operating time during interruptions (internal UPS operation) | 5 minutes per interruption, 60 minutes total operating time without recharging |
Dimensions | 215 mm x 310 mm x 35 mm (8.5 in x 12.2 in x 3.5 in) |
Mass (weight) | 6.3 kg (14 lb) |
Input Specifications | |
Measurement types | One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye |
Input channels | Voltage: 4 channels, ac/dc |
Current: 5 channels | |
Voltage channels | Input resistance: 2 MΩ Input capacitance: < 20 pF |
Current input characteristics | 2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs |
Measuring method | Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops. |
Synchronization and sampling | |
PLL-synchronization source | The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta. |
PLL lock range | 42.5 to 69 Hz |
Sampling frequency | Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz |
A/D resolution | Voltage and current: 24 bits Transient voltage: 14 bits |
Voltage and current measurements | |
Voltage measurement range | AC voltage: 1000 V rms ± 10 % over range DC voltage: ± 1000 V + 10 % over range |
Voltage crest factor | 3 or less |
Current measurement range | Depends on current probe used |
Current crest factor | 4 or less |
Voltage and current measurement accuracy | |
RMS voltage | |
Measurement type | True-rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30. |
Measurement uncertainty | AC: ± 0.2 % reading ± 0.1 % full scale, above 50 V rms DC: ± 0.5 % reading ± 0.2 % full scale, above 50 V dc |
RMS current | |
Measurement type | True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards |
Measurement uncertainty | Ferromagnetic Clamps: ± (0.1 % full scale + 0.2 % reading + current sensor accuracy), valid for 5 % to 100 % of current sensor range |
Flexible Current Probes: ± (0.1 % full scale + 0.5 % reading + current sensor accuracy), valid for 5 % to 100 % of current sensor range | |
See datasheet in resources for additional specifications |