We Stay Abreast of Calibration Requirements Via Certifications and Participation with the NCSLI and A2LA Organization's Technical Committees.
DEKRA has assessed and approved our calibration lab and West Coast distribution center against ISO9001:2015.
A2LA has accredited Electro Rent Calibration Laboratory at Van Nuys, California in accordance with recognized International Standard ISO/IEC17025: 2005. We stay abreast of the ever-changing calibration requirements through the above certifications and through participation with the NCSLI and A2LA organizations technical committees. Our calibration lab implements ANSI Z540-1 along with ISO/IEC 17025 for our internal calibration equipment and when available we can provide calibrations consistent with either ANSI Z540-1, ANSI Z540.3, ISO/IEC 17025 compliant or accredited.
Calibration of the outbound equipment using defined procedures Endorsed with A2LA symbol showing intent is to demonstrate accredited traceability per ILAC Calibration system accredited to ISO/IEC-17025 by APLAC accredited body. ILAC full measurement uncertainty decision rules guardband the included measurement data any non-accredited measurements or exceptions clearly identified.
Recalibration of the in-bound equipment using defined procedures Endorsed with A2LA symbol showing intent is to demonstrate accredited traceability per ILAC Calibration system accredited to ISO/IEC-17025 by APLAC accredited body. ILAC full measurement uncertainty decision rules guardband the included measurement data any non-accredited measurements or exceptions clearly identified.
Calibration of the outbound equipment using defined procedures Endorsed with A2LA symbol showing intent is to demonstrate accredited traceability per ILAC Calibration system accredited to ISO/IEC-17025 by APLAC accredited body, and to section 5.3 of ANSI Z540.3. 2% Probability of False Accept Risk maximum using method 5 or method 6 from Z540.3 Handbook guardband the included measurement data any non-accredited measurements or exceptions clearly identified.
Recalibration of the in-bound equipment using defined procedures Endorsed with A2LA symbol showing intent is to demonstrate accredited traceability per ILAC Calibration system accredited to ISO/IEC-17025 by APLAC accredited body, and to section 5.3 of ANSI Z540.3. 2% Probability of False Accept Risk maximum using method 5 or method 6 from Z540.3 Handbook guardband the included measurement data any non-accredited measurements or exceptions clearly identified.
Calibration of the outbound equipment using defined procedures Certificate for ANSI Z540.3 and ISO 10012 Calibration Systems. 2% Probability of False Accept Risk maximum using method 5 or method 6 from Z540.3 Handbook or 89% in tolerance at end of period using NASA legacy method (no measurement uncertainty calculated.) Inbound equipment screened for out of tolerance conditions. Measurement data is retained on file and not normally supplied.
Calibration of the inbound equipment using defined procedures Certificate for ANSI Z540.3 and ISO 10012 Calibration Systems. 2% Probability of False Accept Risk maximum using method 5 or method 6 from Z540.3 Handbook or 89% in tolerance at end of period using NASA legacy method (no measurement uncertainty calculated.) Inbound equipment screened for out of tolerance conditions. Measurement data is retained on file and not normally supplied.
Re-calibration of the inbound equipment using defined procedures Certificate for ANSI Z540.3 and ISO 10012 Calibration Systems 2% Probability of False Accept Risk maximum using method 5 or method 6 from Z540.3 Handbook or 89% in tolerance at end of period using NASA legacy method (no measurement uncertainty calculated.) Inbound equipment screened for out of tolerance conditions. Measurement data is supplied.
Calibration of the outbound equipment using defined procedures Certificate for ANSI Z540.3 and ISO 10012 Calibration Systems. 2% Probability of False Accept Risk maximum using method 5 or method 6 from Z540.3 Handbook or 89% in tolerance at end of period using NASA legacy method (no measurement uncertainty calculated.) Inbound equipment screened for out of tolerance conditions. Measurement data is supplied outbound.
Calibration of the outbound equipment using defined procedures Certificate for ANSI Z540 Risk controlled through measurement uncertainty or program controls for 4:1 ratio Inbound equipment screened for out of tolerance conditions. Measurement data is retained on file and not normally supplied.
Re-calibration of the inbound equipment using defined procedures Certificate for ANSI Z540 on rental return Risk controlled through measurement uncertainty or program controls for 4:1 ratio Inbound equipment screened for out of tolerance conditions; out of tolerance notification. Measurement data is retained on file and not normally supplied CERTS-ANSI-Z540-CAL/DATA Compliant Calibration Certificate and Data Calibration of the outbound equipment using defined procedures Certificate for ANSI Z540 Risk controlled through measurement uncertainty or program controls for 4:1 ratio Inbound equipment screened for out of tolerance conditions; out of tolerance notification. Measurement data is supplied outbound.
Re-calibration of the inbound equipment using defined procedures Certificate for ANSI Z540 on rental return Risk controlled through measurement uncertainty or program controls for 4:1 ratio Inbound equipment screened for out of tolerance conditions; out of tolerance notification. Measurement data is supplied.
Calibration of the outbound equipment using defined procedures Certificate for ISOIEC17025 Risk controlled through measurement uncertainty or program controls for 4:1 ratio Measurement data is retained on file and not normally supplied.
Recalibration of the inbound equipment using defined procedures and screened for out of tolerance conditions. Certificate for ISOIEC17025 Risk controlled through measurement uncertainty or program controls for 4:1 ratio Measurement data is retained on file and not normally supplied.
Based on our ISO-9001 quality program Calibration of the outbound equipment using defined procedures Measurement data is retained on file and not normally supplied.
Based on our ISO-9001 quality program Recalibration of the inbound equipment using defined procedures and screened for out of tolerance conditions. Measurement data is retained on file and not normally supplied.
Based on our ISO-9001 quality program Calibration of the outbound equipment using defined procedures Measurement data is supplied.
Based on our ISO-9001 quality program Recalibration of the inbound equipment using defined procedures and screened for out of tolerance conditions. Measurement data is supplied.
Purchased calibration for specific needs of the customer. Order technical notes will provide guidance for fulfillment. Purchased calibration documents provided as-is from the vendor.