Configured models contain the following attributes:
Power Supplies / Electronic LoadsRegenerative Power SuppliesPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Please refer to the Resources section for Datasheets or see the Product Overview.
If you would like to know more, please get in touch and one of our team will be happy to help.
The RP7900 Series regenerative power supply provides both sourcing and electrical loading up to 30 kW. A bidirectional supply is ideal for testing energy storage and converters. Most electronic loads convert energy to heat which can cause a temperature rise in a rack — leading to measurement errors. A regenerative power supply safely returns the energy to the grid eliminating additional costs to remove the excess heat.
The RP7900 Series regenerative power supply can operate in voltage or current priority. Voltage priority allows positive and negative current limits. The power supply can seamlessly change from sourcing current to sinking current. When testing energy storage systems, it is important to be able to switch between sourcing and sinking current.
The RP7984A regenerative power system is a single output, bi-directional, regenerative DC power supply with highly integrated safety features that protect both your people and your device under test. The regenerative capability enables the energy normally consumed to be returned to the grid cleanly, saving costs associated with energy consumption and cooling.
In addition, by combining the seamless source and load functionality into a compact 5U-high package, not only do you save energy but also floor space and integration time. The RP7984A delivers the fastest, most accurate, integrated regenerative power system.
The RP7984A is a part of Keysight’s HEV/EV Power Converter Test Solutions that give you confidence to deploy high-voltage, high-power solutions to meet the fast paced, high-growth demands of the HEV/EV market.
Key Features |
Output ratings: 1500 V, ±60 A, 30 kW. |
Operate in two-quadrant mode as power source and regenerative electronic load. |
Maximize throughput with fast output speed and sub-millisecond command-processing time. |
Create up to 600 kW power or loading through easy parallel connection. |
Reduce cost for cooling and electricity with eco-friendly, regenerative design. |
Save valuable rack space with compact 5U-high size. |
A part of Keysight’s HEV/EV Power Converter Test Solutions. |
Benefits | |
Pathwave Benchvue Advanced Battery Test and Emulation Software | Achieve higher accuracy, repeatability, and safety with an emulation-based unique battery model. Modeling enables you to determine your device's power consumption, emulate an actual battery, and import existing battery models. See how your device consumes power and simulate actual batteries. Import existing battery model data from a CSV file or integrate into an existing program with API calls. Test and emulate batteries up to 200 kW and up to 2 kV. Profile batteries through charge / discharge to create a unique battery model. Emulate charge states to reduce test time, improve safety, and test repeatability. View the charge / discharge and cycle batteries process to determine capacity, loss of capacity, and reduction of battery life. |
Seamlessly Source and Sink Current | The RP7900 Series regenerative power supply can operate in voltage or current priority. Voltage priority allows positive and negative current limits. The power supply can seamlessly change from sourcing current to sinking current. When testing energy storage systems, it is important to be able to switch between sourcing and sinking current. |
Specifications | |||||
RP7900 Series Regenerative Power Supplies | |||||
Model Overview | |||||
Model | Max. Voltage Per Output | Max. Current per Output | Max. Power | No. of Outputs | Type |
200/208 VAC Models | |||||
RP7931A | 20 V | ±400 A | 5 kW | 1.0 | ATE / 3U |
RP7932A | 80 V | ±125 A | 5 kW | 1.0 | ATE / 3U |
RP7933A | 20 V | ±800 A | 10 kW | 1.0 | ATE / 3U |
RP7935A | 80 V | ±250 A | 10 kW | 1.0 | ATE / 3U |
RP7936A | 160 V | ±125 A | 10 kW | 1.0 | ATE / 3U |
RP7951A | 500 V | ±20 A | 5 kW | 1.0 | ATE / 3U |
RP7952A | 500 V | ±40 A | 10 kW | 1.0 | ATE / 3U |
RP7953A | 950 V | ±20 A | 10 kW | 1.0 | ATE / 3U |
400/480 VAC Models | |||||
RP7941A | 20 V | ±400 A | 5 kW | 1.0 | ATE / 3U |
RP7942A | 80 V | ±125 A | 5 kW | 1.0 | ATE / 3U |
RP7943A | 20 V | ±800 A | 10 kW | 1.0 | ATE / 3U |
RP7945A | 80 V | ±250 A | 10 kW | 1.0 | ATE / 3U |
RP7946A | 160 V | ±125 A | 10 kW | 1.0 | ATE / 3U |
RP7961A | 500 V | ±20 A | 5 kW | 1.0 | ATE / 3U |
RP7962A | 500 V | ±40 A | 10 kW | 1.0 | ATE / 3U |
RP7963A | 950 V | ±20 A | 10 kW | 1.0 | ATE / 3U |
RP7972A | 1000 V | ±60 A | 20 kW | 1.0 | ATE / 3U |
RP7973A | 2000 V | ±30 A | 20 kW | 1.0 | ATE / 3U |
RP7982A | 1000 V | ± 90 A | 30 kW | 1.0 | ATE / 5U |
RP7983A | 2000 V | ± 30 A | 30 kW | 1.0 | ATE / 5U |
RP7984A | 1500 V | ± 60 A | 30 kW | 1.0 | ATE / 5U |
Specifications | |
RP7900 Series Regenerative Power Supplies | |
Model Overview | |
Model | Description |
200/208 VAC Models | |
RP7931A | Regenerative Power System; 20 V, ± 400 A, 5 kW, 200/208 VAC |
RP7932A | Regenerative Power System; 80 V, ± 125 A, 5 kW, 200/208 VAC |
RP7933A | Regenerative Power System; 20 V, ± 800 A, 10 kW, 200/208 VAC |
RP7935A | Regenerative Power System; 80 V, ± 250 A, 10 kW, 200/208 VAC |
RP7936A | Regenerative Power System; 160 V, ± 125 A, 10 kW, 200/208 VAC |
RP7951A | Regenerative Power System; 500 V, ± 20 A, 5 kW, 200/208 VAC |
RP7952A | Regenerative Power System; 500 V, ± 40 A, 10 kW, 200/208 VAC |
RP7953A | Regenerative Power System; 950 V, ± 20 A, 10 kW, 200/208 VAC |
400/480 VAC Models | |
RP7941A | Regenerative Power System; 20 V, ± 400 A, 5 kW, 400/480 VAC |
RP7942A | Regenerative Power System; 80 V, ± 125 A, 5 kW, 400/480 VAC |
RP7943A | Regenerative Power System; 20 V, ± 800 A, 10 kW, 400/480 VAC |
RP7945A | Regenerative Power System; 80 V, ± 250 A, 10 kW, 400/480 VAC |
RP7946A | Regenerative Power System; 160 V, ± 125 A, 10 kW, 400/480 VAC |
RP7961A | Regenerative Power System; 500 V, ± 20 A, 5 kW, 400/480 VAC |
RP7962A | Regenerative Power System; 500 V, ± 40 A, 10 kW, 400/480 VAC |
RP7963A | Regenerative Power System; 950 V, ± 20 A, 10 kW, 400/480 VAC |
RP7972A | Regenerative Power System PV Mode; 1000 V, ± 60 A, 20 kW, 400/480 VAC |
RP7973A | Regenerative Power System PV Mode; 2000 V, ± 30 A, 20 kW, 400/480 VAC |
RP7982A | Regenerative Power System PV Mode; 1000 V, ± 90 A, 30 kW, 400/480 VAC |
RP7983A | Regenerative Power System PV Mode; 2000 V, ± 30 A, 30 kW, 400/480 VAC |
RP7984A | Regenerative Power System PV Mode; 1500 V, ± 60 A, 30 kW, 400/480 VAC |