I modelli configurati contengono le seguenti caratteristiche:
RF & Microwave Network AnalyzersNetwork Analyzers <20GHz20GHz <= 50GHz1kHz <= 100kHzUtilizza "Preventivo rapido" e ti contatteremo per fornirti un preventivo per le tue esigenze.
Puoi anche contattarci, se preferisci, e i nostri esperti ti guideranno a trovare la giusta applicazione e soluzione di acquisto per questo prodotto.
Attributo | Valore |
---|---|
High Frequency (range) | 20GHz <= 50GHz |
Low Frequency (range) | 1kHz <= 100kHz |
Compact, faceless, vector network analyzer (VNA). Flexible two-port VNA dramatically reduces your size of test. Up to 20 GHz.
The freedom of portable network analysis doesn’t have to mean a compromise in performance. The B-models of the Keysight Streamline Series VNAs unlock the full performance of the network analyzer hardware with fast measurements over Thunderbolt 3 connections to your host PC. Gain confidence in your measurements with best-in-class performance offering fast, reliable, and repeatable results. Explore the complete characterization of your devices with a rich portfolio of software applications that transform the compact network analyzer into a complete RF measurement solution.
The P50xxB series offers the performance required for testing passive components, amplifiers, mixers or frequency converters. The vector network analyzer (VNA) provides best-in-class key specifications such as dynamic range, measurement speed, trace noise and temperature stability. Choose from 2- or 4-port models up to 53 GHz, or 6-port models up to 20 GHz.
The Streamline Series utilizes the same measurement science as other Keysight VNAs such as the PNA, ENA and PXI VNA. A common software platform makes it easy to choose the right level of performance to match budget and measurement needs. This commonality guarantees measurement consistency, repeatability, and a common remote-programming interface across multiple instruments in R&D and manufacturing
Key Features |
2-port, 100 kHz to 53 GHz |
Improve throughput with fast Thunderbolt 3 interface |
Choose from a wide range of measurement applications to gain deeper insight into your component tests |
Share the portable VNA with other teams and locations |
Extend the number of test ports by cascading two VNAs |
Measure with the same GUI, SCPI commands, and measurement science as Keysight’s trusted high-performance VNAs |
Calibrate quickly with Keysight Electronic Calibration (ECal) modules |
Upgrade your hardware with high performance-enabling software |
Keep your instrument up to date with VNA activation software |
Specifications | |
Streamline Series Vector Network Analyzer (B-models) | |
Feature | Parameter |
System IF Bandwidth Range | P9370B to P9377B: 1 Hz to 700 kHz P9382B: 1 Hz to 700 kHz P9384B: 1 Hz to 700 kHz P5000B to P5008B: 1 Hz to 15 MHz P5020B to P5028B: 1 Hz to 15 MHz |
Number of Points | 1 to 100,003 |
PC System Requirement | Operating Systems: Windows 10 (64-bit) Available Memory: 16 GB recommended, 4 GB minimum Available Disk Space: 4 GB minimum Display Resolution: 1024 x 768 minimum Connection with VNA: Thunderbolt 3 and Thunderbolt 4 Recommended CPU: Intel Core i7 10th Generation or later recommended |
Instrument Drivers | Keysight IO Libraries: Keysight IO Libraries Suite 2022 Update 1 (18.2.28014.7) or later |
Temperature | Operating: 0 to 50 °C ambient 10 to 70 °C instrument temperature Non Operating: -40 to 70 °C |
Humidity | Operating: Type tested at 20 to 80 %, wet bulb temperature < 29 °C (non-condensing) Non Operating: Type tested at 20 to 90 %, wet bulb temperature < 40 °C (non-condensing) |
Altitude | Operating: Up to 2,000 meters (6,561 feet) Non Operating: Up to 4,572 meters (15,000 feet) |
Vibration | Operating: 0.3 G maximum, 5 Hz to 500 Hz Non Operating: 0.75 G maximum, 5 Hz to 500 Hz |
Instrument Protection | IP 30 IEC/EN 60529 |
Warm up Time | 60 minutes |
Specifications | |||
P500xB Series | |||
Model Overview | |||
Model ¹ | Description | Ports | Test Port Connectors |
P5000B | 9 kHz to 4.5 GHz | 2 | 3.5 mm (f) |
P5001B | 9 kHz to 6.5 GHz | 2 | 3.5 mm (f) |
P5002B | 9 kHz to 9 GHz | 2 | 3.5 mm (f) |
P5003B | 9 kHz to 14 GHz | 2 | 3.5 mm (f) |
P5004B | 9 kHz to 20 GHz | 2 | 3.5 mm (f) |
P5005B | 100 kHz to 26.5 GHz | 2 | 3.5 mm (f) |
P5006B | 100 kHz to 32 GHz | 2 | 2.4 mm (f) |
P5007B | 100 kHz to 44 GHz | 2 | 2.4 mm (f) |
P5008B | 100 kHz to 53 GHz | 2 | 1.85 mm (f) |
Specifications | |||
P937xB Series | |||
Model Overview | |||
Model ¹ | Description | Ports | Test Port Connectors |
P9370B | 9 kHz to 4.5 GHz | 2 | 3.5 mm (f) |
P9371B | 9 kHz to 6.5 GHz | 2 | 3.5 mm (f) |
P9372B | 9 kHz to 9 GHz | 2 | 3.5 mm (f) |
P9373B | 9 kHz to 14 GHz | 2 | 3.5 mm (f) |
P9374B | 9 kHz to 20 GHz | 2 | 3.5 mm (f) |
P9375B | 100 kHz to 26.5 GHz | 2 | 3.5 mm (f) |
P9377B | 100 kHz to 44 GHz | 2 | 2.4 mm (f) |
Specifications | |||
P938xB Series | |||
Model Overview | |||
Model ¹ | Description | Ports | Test Port Connectors |
P9382B | 9 kHz to 9 GHz | 4 | 3.5 mm (f) |
P9384B | 9 kHz to 20 GHz | 4 | 3.5 mm (f) |
Specifications | |||
P502xB Series | |||
Model Overview | |||
Model ¹ | Description | Ports | Test Port Connectors |
P5020B | 9 kHz to 4.5 GHz | 4 or 6 | 3.5 mm (f) |
P5021B | 9 kHz to 6.5 GHz | 4 or 6 | 3.5 mm (f) |
P5022B | 9 kHz to 9 GHz | 4 or 6 | 3.5 mm (f) |
P5023B | 9 kHz to 14 GHz | 4 or 6 | 3.5 mm (f) |
P5024B | 9 kHz to 20 GHz | 4 or 6 | 3.5 mm (f) |
P5025B | 100 kHz to 26.5 GHz | 4 | 3.5 mm (f) |
P5026B | 100 kHz to 32 GHz | 4 | 2.4 mm (f) |
P5027B | 100 kHz to 44 GHz | 4 | 2.4 mm (f) |
P5028B | 100 kHz to 53 GHz | 4 | 1.85 mm (f) |
Note:
¹ The B-models of Keysight Streamline Series VNAs include:
Thunderbolt 3 cable assembly for connection with a host PC (800-mm, P/N: 8121-3588)
Power Supply (external AC-DC adapter.
P/N: 0950-6128 for P937xB/P500xB
P/N: 0950-6166 for P938xB/P502xB)
Power Cord