The VIAVI SmartClass optical handhelds go beyond the basics. The SmartClass OCC-56C is a handheld, battery-operated dense wavelength division multiplexing (DWDM) channel checker that is ideal for field service groups tasked with the installation, maintenance, and upgrades of DWDM systems.
The SmartClass OCC-56C scans the DWDM system and automatically records all channels with the wavelength/ frequency and the related power level. Information can be displayed in a graphical spectrum format or in a table of results so that users can easily check the performance of each and every channel.
Benefits:
- Industry’s smallest and lightest DWDM channel checker
- Supports C-band applications
- Outstanding battery life ensures highest flexibility
- Graphical/tabular display mode
- Supports 100 or 200 GHz channel spacing (according to ITU-T)
- Save results via internal memory or external USB memory stick
- Report generation software OFS-355
Specifications |
|
OCC-56C |
|
General |
|
Wavelength Range | 1528.77 to 1564.68 nm; 196.10 to 191.60 THz |
Wavelength Accuracy | typ. ± 50 pm |
Channel Spacing | 100/200 GHz |
Channel Power Range | <-70 to +10 dBm |
Absolute Accuracy(1)(2) | <±1 dB |
Readout Resolution | ±0.01dB |
Filter Bandwidth @3 dB | min. 0.34 nm |
Measurement Time | ~ 10 s (full span, 46 ch) typ |
Optical Interface | Interchangeable APC |
Max. Composite Power | +22 dBm all channels; +10 dBm one channel |
Return Loss | >35 dB |
Graphical Display Trace | Bar graph, 50 GHz/pixel |
Table | ch-no, wavelength, power |
Functions | Zoom, marker |
Sweep Mode | Single, continuous |
Remote Control | via USB interface |
Specifications |
|
OCC-56C |
|
Display | Graphical display, resolution of 128 × 64 dots, displays up to four laser status screens
Backlight function switchable via a separate key
|
|
|
Optical Adapters | Interchangeable optical adapters. SC, FC, ST, LC- type available. |
Power
Power Supply
Operating time from dry batteries
|
Four dry batteries Mignon/AA, 1.5 V or NiMH rechargeable cells Mignon/AA, 1.2 V
typ. 7 h(3)
|
Power Saving | The instrument switches off automatically after ~20 min (function can be disabled)
AC line operation via separate AC adapter
Integrated fast battery charging function (2 hours)
|
Electromagnetic Compatibility | Corresponds to IEC 61326 (CE conformance) |
Calibration
Suggested Calibration Interval
|
3 years
|
Temperature
Operation
Storage
|
−5 to +55°C
−40 to +70°C
|
Dimensions and Weight
W × H × D (approximately)
Weight (approximately)
|
95 × 60 × 195 mm (3.74 × 2.36 × 7.68 in)
500 g (1.1 lb)
|
Notes:
(1) For input levels -60 to +5 dBm
(2) 23°C ±5°C
(3) Single sweep mode
Specifications |
|
OCC-56C |
|
Ordering Information |
|
Part Number | Description |
Base Unit |
|
BN 2277/44 | OCC-56 C (C-band) |
SmartClass OCC-56 Includes |
|
BN 2237/90.02 | 4 NiMH rechargeable cells (AA) |
BN 2277/90.01 | SNT-121A Worldwide compatible AC adapter |
BN 2277/98.22 | Operating manual BN 2277/98.22 |
BN 2277/90.02 | MT-1S belt bag for one instrument |
SC-type (2155/06) mounted; FC-type (2155/05) included | Interchangeable adapter |
Specifications |
|
OCC-56C |
|
Accessories |
|
Ordering Information |
|
Part Number | Description |
BN 2155/00.32 | Optical adapter ST type |
BN 2155/06 | Optical adapter SC type |
BN 2155/05 | Optical adapter FC type |
BN 2155/07 | Optical adapter LC type |
BN 2229/90.21 | OCK-10 Optical Connector Cleaning Kit |
BN 2237/90.02 | NiMH cells, Mignon/AA, 1.2 V (4 required per instrument) |
BN 2277/90.01 | SNT-121A Worldwide compatible AC adapter |
BN 2277/90.02 | MT-1S belt bag for one instrument |