I modelli configurati contengono le seguenti caratteristiche:
LCR / Impedance AnalyzersSemiconductor Test Equipment1kHz <= 100kHzUtilizza "Preventivo Rapido" o "Configura unità" e ti contatteremo per fornirti un preventivo per le tue esigenze.
Puoi anche contattarci, se preferisci, e i nostri esperti ti guideranno a trovare la giusta applicazione e soluzione di acquisto per questo prodotto.
Attributo | Valore |
---|---|
High Frequency (range) | 1kHz <= 100kHz |
Keithley’s Standard Series 2400 Source Measure Unit (SMU) Instruments offer four-quadrant precision voltage and current source/load coupled with measurement. Each SMU instrument is both a highly stable DC power source and a true instrument-grade 6½-digit multimeter. The power source characteristics include low noise, precision, and readback. The multimeter capabilities include high repeatability and low noise.
Keithley’s SourceMeter family is designed specifically for test applications that demand tightly coupled sourcing and measurement. All SourceMeter models provide precision voltage and current sourcing as well as measurement capabilities.
Each SourceMeter instrument is both a highly stable DC power source and a true instrument-grade 51 ⁄2-digit multimeter. The power source characteristics include low noise, precision, and readback. The multimeter capabilities include high repeatability and low noise. The result is a compact, single-channel, DC parametric tester. In operation, these instruments can act as a voltage source, a current source, a voltage meter, a current meter, and an ohmmeter.
Manufacturers of components and modules for the communications, semiconductor, computer, automotive, and medical industries will find the SourceMeter instruments invaluable for a wide range of characterization and production test applications.
Key Features |
Family of products offers wide dynamic range: 10pA to 10A, 1µV to 1100V, 20W to 1000W |
4-quadrant operation |
0.012% basic accuracy with 51 ⁄2-digit resolution |
6-wire Ω measurement with programmable I source and V clamp |
1700 readings/second at 41 ⁄2 digits via GPIB |
Built-in comparator for fast pass/fail testing |
Optional contact check function |
Digital I/O for fast binning and connection to component handlers |
GPIB, RS-232, and Trigger Link interfaces |
TestPoint™ and LabVIEW™ drivers |
Specifications | |
Series 2400 SourceMeter Line | |
Series Overview | |
Model | Description |
2400 | 200V, 1A, 20W SourceMeter |
2400-C | 200V, 1A, 20W SourceMeter with Contact Check |
2400-LV | 20V, 1A, 20W SourceMeter |
2410 | 1100V, 1A, 20W SourceMeter |
2410-C | 1100V, 1A, 20W SourceMeter with Contact Check |
2420 | 60V, 3A, 60W SourceMeter |
2420-C | 60V, 3A, 60W SourceMeter with Contact Check |
2425 | 100V, 3A, 100W SourceMeter |
2425-C | 100V, 3A, 100W SourceMeter with Contact Check |
2430 | 100V, 10A, 1000W Pulse Mode SourceMeter |
2430-C | 100V, 10A, 1000W Pulse Mode SourceMeter with Contact Check |
2440 | 40V, 5A, 50W SourceMeter |
2440-C | 40V, 5A, 50W SourceMeter with Contact Check |
Legacy Products and Suggested Alternatives:
The 2400, 2410, 2420, and 2440 SourceMeter SMU Instruments in this datasheet are classified as “Legacy Products”. They have been succeeded by Keithley’s newer 2400 Series Graphical SourceMeter SMUs with improved and greater performance. For new applications and designs, Keithley recommends you consider using the newer graphical models. The table provides a list of suggested graphical models for new applications and designs.
Specifications | ||
Legacy Products and Suggested Alternatives | ||
Legacy Model | Model Type | Graphical Model |
2400 | Basic/ Standard | 2450 |
2410 | High Voltage | 2470 |
2420 | High Current | 2460 or 2461 |
2440 | High Current | 2460 or 2461 |
Keithley’s Standard Series 2400 Source Measure Unit (SMU) Instruments offer four-quadrant precision voltage and current source/load coupled with measurement. Each SMU instrument is both a highly stable DC power source and a true instrument-grade 6½-digit multimeter. The power source characteristics include low noise, precision, and readback. The multimeter capabilities include high repeatability and low noise.
Specifications | ||||||
Keithley 2400 Standard Series SMU | ||||||
Model | Touchscreen | Channels | Max Current Source / Measure Range | Max Voltage Source / Measure Range | Measurement Resolution (Current / Voltage) | Power |
2401 | No | 1 | 1A | 20V | 1pA / 100nV | 20 W |
2400 | No | 1 | 1A | 200V | 1pA / 100nV | 20 W |
2420 | No | 1 | 3A | 60V | 10pA / 100nV | 60 W |
2410 | No | 1 | 1A | 1100V | 1pA / 100nV | 20 W |
2440 | No | 1 | 5A | 40V | 10pA / 100nV | 50 W |
Specifications | |
Keithley 2400 Standard Series SMU | |
Model Overview | |
Model | Description |
2400 | 200V, 1A, 20W SourceMeter SMU Instrument |
2401 | 20V, 1A, 20W SourceMeter SMU Instrument |
2410 | 1100V, 1A, 20W SourceMeter SMU Instrument |
2420 | 60V, 3A, 60W SourceMeter SMU Instrument |
2440 | 40V, 5A, 50W SourceMeter SMU Instrument |
Legacy Products and Suggested Alternatives:
The 2400, 2410, 2420, and 2440 SourceMeter SMU Instruments in this datasheet are classified as “Legacy Products”. They have been succeeded by Keithley’s newer 2400 Series Graphical SourceMeter SMUs with improved and greater performance. For new applications and designs, Keithley recommends you consider using the newer graphical models. The table provides a list of suggested graphical models for new applications and designs.