Power analyzers are available in different accuracy classes, to allow the user to choose the right tool for the job at hand. After all, not all applications require maximum precision; often lower resolution and frequency range are sufficient.
Unfortunately, not all measuring applications exhibit this distinction. It is very well possible, for instance, to have need for different frequency ranges and accuracy levels at different points in the same measurement configuration. This is why the LMG600 offers three different channel types, which can be combined in the same chassis without problems to ensure that you always have a measuring device tailored to your needs for your particular application.
No need to accept trade-offs in accuracy or take a sledgehammer to crack a nut, if a lower priced solution could have served your purposes equally well.
Key Features | |
Measurement Channels | Outstanding accuracy of 0.015% of measured value + 0.01% of range Full dynamic range of 500 µA to 32 A / 3 mV to 1000 V per channel available in single instrument Power measurements from standby to full load (max. 32 A) without mechanical changes Analog bandwidth DC up to 10 MHz Modular configuration with 1 to 7 power measurement channels (alternatively 6 channels + 1 I/O card) Gapless sampling up to 18 bit and a minimal cycle time of 10 ms Delay time between V and I input < 3ns, very precise measurements at small power factors (PF) and/or high frequencies |
Features | Simultaneous measurement of narrow- and broadband values through innovative DualPath architecture Simultaneous capturing of fundamental frequency and broadband RMS values for instantaneous detection of losses, resp. high-frequency components Harmonics and interharmonics up to 2000. order, as required by EN61000-4-7 With optional I/O card speed/torque inputs freely configurable for all signal types (analogue, frequency as RS422,TTL or HTL) via menu Flexible scripting tool for custom applications Simultaneous measurement of V, I, P values and harmonics, presentation in tabular or graphical form Signal filters freely configurable by frequency, type and characteristics Synchronization to up to 7 different frequencies simultaneously Flicker measurement, interactions between grid and appliance according to EN61000-4-15 |
User-Interface | Large and clearly arranged touchscreen GUI for intuitive handling All instrument features displayed, identical look-and-feel for local and remote operation for quick and easy familiarization |
Memory and Interfaces | Internal storage of long-term measurements even with shortest cycle-time thanks to integrated mass storage device Excellent connectivity via USB3.0, Gbit-LAN, RS-232 and DVI |
Benefits | |
Fits to your task | Configure the number and kind of your power channels for the best price and performance Sync to different frequencies on each channel group Focus on the relevant signal content with highly versatile filters Customize your analysis in content and appearance |
Barrier-free measurements | Quickly familiarize yourself with our touchscreen GUI Adapt it to your own needs with a few clicks Enhance your screenshots with on-screen comments and sketches Add sensors using Plug‘n‘Measure |
Specifications | |
LMG671 1 to 7 Channel Power Analyzer | |
Feature | Parameter |
Dimensions (W x H x D) | LMG671 (Table top): 433 mm x 177 mm x 590 mm LMG671 (Rack): 84 HP x 4 RU x 590 mm |
Weight | Depending on installed options: max. 18.5 kg |
Protection Class | EN 61010 (IEC 61010, VDE 0411), protection class I / IP20 in accordance with EN 60529 |
Electromagnetic Compatibility | EN 61326 |
Temperature | 5 ... 40 °C (operation) / -20 ... 50 °C (storage) |
Climatic Category | Normal environmental conditions according to EN 61010 |
Line Input | 100 ... 230 V, 47 ... 63 Hz, max. 400 W |
Specifications | |
LMG671 Power Analyzer | |
Option Overview | |
Option | Description |
L6-OPT-DRV | Option Package for Frequency Converters for LMG600 (at least 3 power channels of same type), consisting of: - L6-PSI: Process Signal Interface - L6-SDC: Star-Delta-Conversion - L6-HRM: Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics) |
L6-OPT-TRAFO | Option Package for Transformers for LMG600 (at least 3 power channels of same type), consisting of: - L6-SDC: Star-Delta-Conversion - L6-HRM: Harmonic analysis up to max. 1.000th order (2.000th order with interharmonics) |
L6-OPT-CE-FLK | Option Package CE Flicker for LMG600, consisting of: - the LMG flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as - the PC software* LMG Test Suite (LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-3 and EN61000-3-11 for 1-phase and 3-phase* equipment under |
L6-OPT-CE-HRM | Option Package CE Harmonics for LMG600, consisting of: - the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM) as well as - the PC software* LMG Test Suite (LMG-TEST-CE-HRM) for analysis of measured values according to EN61000-3-2 and EN61000-3-12 for 1-phase and 3-phase* equipment under test |
L6-OPT-CE-HRMFLK | Option Package CE Harmonics and Flicker for LMG600, consisting of: - the harmonic analysis of the measured signals in the LMG (L6-OPT-HRM), - internal flicker meter according to EN61000-4-15 (L6-OPT-FLK) as well as - the PC software* LMG Test Suite (LMG-TEST-CE-HRM + LMG-TEST-CE-FLK) for analysis of measured values according to EN61000-3-2 / EN61000-3-12 and EN61000-3-3 / EN61000-3-11, each for 1-phase and 3-phase* equipment under test |
L671-OPT-DVI | DVI Interface for connection of an external display, beamer, touch device |
L6-OPT-PSI | Process Signal Interface 8 digital inputs, 8 digital outputs, 2 fast analog inputs (150 kS/s, 15 kHz bandwidth), 8 slow analog inputs (DC), 32 analog outputs, 2 frequency inputs (frequency, orientation, position; DTL, HTL or differential) |
L6-OPT-CAN | CAN bus Interface CAN bus connectivity according to ISO 11898-2 (high-speed CAN) - bit rate: 5 kbit/s to 1Mbit/s - galvanic separation at CAN connector: up to 500V - active support of CAN 2.0A and B standards - Standard Frame Format or Extended Frame Format for sending measurement results - manual polling of measurement values possible via Remote Transmission Request (RTR) |
L6-OPT-SDC | Star-Delta-Conversion Minimum requirement LMG600 with at least 3 power channels of the same type |
L6-OPT-EVT | Event Triggering triggering on crossing voltage or current thresholds recording of 16 tracks with up to 16 million values each |
L6-OPT-HRM | Harmonic Analysis up to max. 1000th order (2000th order with interharmonics) of U, I, P, Q and S, fundamental 3 ... 1200 Hz, up to 150 kHz (A channel) resp. 15 kHz (B channel) or 10 kHz (C channel) with anti-aliasing filter, customizable settings for the detection of interharmonics |
L6-OPT-FLK | Flicker meter according to EN61000-4-15 |
L6-OPT-SMV | Smart Vision Smart add-on functions for the convenient evaluation of measurements The package includes: - Painter: screenshots can be enriched with valuable additional information directly in the GUI before saving - Env Var Watcher: script-controlled visual watchdog as part of a custom menu |
L6-OPT-SPV | Sample Value Analysis Module for LMG600 Software* for continuous and gapless streaming of sample values on 16 tracks at a rate of 10 kS/s (up to 1.2 MS/s under optimal conditions), furthermore: - display of sample recordings in ZLR format - display of frequency spectrum of recorded sample values - calculation of RMS values of voltage, current and power - CSV or MATLAB export of frequency spectrum and RMS values |
L671-OPT-SSD | Mass Storage Device for Measurement Results Internal mass storage device for long-time recording of measurements (capacity 250 GB) Some space is used for the system. |
NOTE:
* System Requirements:
- Operating system: Windows 7/8/10 (32/64 bit)
- Hard drive: software: min. 50 MB, data: approx. 20 MB per minute of measurement/phase
- RAM memory: min. 2 GB
- Processor: min. 2 GHz, dual-core
- Interfaces supported: Gbit-Ethernet