Configured models contain the following attributes:
Network & Fiber InstallationsOptical Time Domain Reflectometers1310/1550nmAPCModularPlease use 'Get Quick Quote' and we’ll contact you and quote for your exact need.
You can also get in touch, if you prefer, and our experts will be able to guide you with the right application and procurement solution for this product.
Attribute | Value |
---|---|
Wavelength | 1310/1550nm |
Connector Type | APC |
Form Factor | Modular |
VIAVI 4100-Series OTDR modules enable field technicians to rapidly, reliably, and cost-effectively install, turn up, and troubleshoot any optical network architecture – The optical performances of the 4100-Series OTDR modules combined with the complete suite of T-BERD/MTS, CellAdvisor 5G or OneAdvisor-800 platforms testing features ensure that any testing job is done right the first time.
Fiber infrastructure is the foundation of the network performance and the quality of delivered services. An OTDR is the only tool that verifies the condition of installed cables and passive components to ensure fiber links meet design specifications and contractor’s workmanship meets the required quality.
Module portability allows migration of fiber test capabilities between different VIAVI platforms, offering the flexibility to move existing fiber certification tools to different technologies such as coax and RF, active xWDM, MPO/ribbon cables or network layer tests such as Ethernet, BERT, CPRI, etc.
Key Features |
Up to 45 dB dynamic range and 256,000 acquisition points |
PON optimized to test through up to a 1x128 splitter |
Combined singlemode/multimode version |
Single-/Dual-/Tri-wavelength versions with 1310,1490,1550,1625, and 1650nm |
Single connector port for 1310, 1550 and in-service 1625 or 1650nm wavelengths |
Integrated light source and power meter on OTDR port |
Available in FiberComplete version for automated bi-directional OTDR, IL and ORL measurements |
Benefits |
Combines OTDR, power meter and continuous light source for added testing flexibility |
Performs accurate PON networks troubleshooting with dedicated wavelengths for in-service troubleshooting |
Avoids the risk of live signal interference or damage to the optical transmitter when performing OTDR test with instantaneous automatic traffic detection |
Specifications | |||||
4100B and 4100C Series OTDR Modules | |||||
OTDR Specifications (Typical at 25°C) | |||||
Model | Central Wavelengths (4) | RMS Dynamic Range (5) | Event Dead Zone (6) | Attenuation Dead Zone (7) | Splitter Attenuation Dead Zone (8) |
4100 B | 1310 ±20 nm 1550 ±20 nm 1625 ±10 nm 1650 ±10 nm | 42 dB 40 dB 40 dB 40 dB | 0.65 m | 3 m | 45 m (8) |
4100 C | 1310 ±20 nm 1550 ±20 nm 1625 ±10 nm 1650 ±10 nm | 45 dB 43 dB 43 dB 42 dB | 0.65 m | 2.5 m | 20 m (9) |
Notes:
(1) Excluding group index uncertainties
(2) Except filtered wavelengths
(3) At calibrated wavelengths, at -30dBm excluding connection uncertainty’
(4) Laser at 25°C and measured at 10µs
(5) The one-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging
(6) Measured at ±1.5 dB down from the peak of an unsaturated reflective event, using 5ns pulsewidth
(7) Measured at ±0.5 dB down from the linear regression using a FC/UPC-type reflectance, using 5ns pulsewidth
(8) Measured on a 16 dB loss (typical 1x32 split ratio) non-reflective splitter at 1310nm, using 200ns pulsewidth
(9) Measured on a 16 dB loss (typical 1x32 split ratio) non-reflective splitter at 1310nm, using 100ns pulsewidth
Specifications | |
4100B and 4100C Series OTDR Modules | |
Model Overview | |
Model / Part Number | Description |
E4126B-PC/-APC | 4100 MODULE B OTDR - 1310/1550 NM – PC/APC |
E4136B-PC/-APC | 4100 MODULE B OTDR - 1310/1550/1625 NM – PC/APC |
E4138FB65-APC | 4100 MODULE B OTDR - 1310/1550/Filtered 1650 NM – APC |
E4118FB65-APC | 4100 MODULE B OTDR - Filtered 1650 NM – APC |
E4126C-PC/-APC | 4100 MODULE C OTDR - 1310/1550 NM – PC/APC |
E4136C-PC/-APC | 4100 MODULE C OTDR - 1310/1550/1625 NM – PC/APC |
E4136FC-APC | 4100 MODULE C OTDR - 1310/1550/Filtered 1625 NM – APC |
E4138FC65-APC | 4100 MODULE C OTDR - 1310/1550/Filtered 1650 NM – APC |
EUSCADS, EULCADS, EUFCADS | Universal PC connector adapters |
EUSCADS-APC, EULCADS-APC, EUFCADS | Universal APC connector adapters |
E41OTDRPM | Optical power meter option |