Los modelos configurados tienen las siguientes opciones:
Network & Fiber InstallationsOptical Time Domain ReflectometersModularUtilice "Presupuesto Rápido" y nos pondremos en contacto con usted y le cotizaremos para su necesidad exacta.
También puede ponerse en contacto, si lo prefiere, y nuestros expertos podrán orientarlo con la aplicación y la solución de adquisición adecuadas para este producto.
Atributo | Valor |
---|---|
Form Factor | Modular |
CWDM OTDR Modules – 4100-Series for T-BERD/MTS-2000, -4000 V2 and 5800 Platforms.
A CWDM OTDR test solution to deploy or maintain and troubleshoot in-service CWDM fiber networks.
VIAVI CWDM OTDR solution enables cable operators, dark fiber providers and telecommunication service providers to test through MUX/DEMUX and perform a complete end-to-end link characterization or troubleshooting of active C-RAN, DAS and mobile fronthaul CWDM networks. Learn more about OTDR Testing.
4100-Series CWDM OTDR Modules; For T-BERD/MTS-2000, −4000 V2, −5800 Platforms
Connect the VIAVI 4100-Series CWDM OTDR family to successfully deploy and maintain C-RAN, DAS, CWDM, and fronthaul networks. CWDM OTDRfamily optical performance, combined with the T-BERD®/MTS platform’s suite of testing features, ensures that testing jobs are performed right—the first time.
Key Features |
CWDM8U version includes 8 wavelengths from 1471nm to 1611nm |
CWDM10U version includes 10 wavelengths from 1431nm to 1611nm |
CWDM10L version includes 10 wavelengths from 1271nm to 1451nm |
Integrated CW light source with modulation capability (same OTDR wavelengths) |
Eliminate OTDR interpretation errors with Smart Link Mapper (SLM) option (converts the OTDR trace into icons – splice, connector, MUX/DEMUX) |
Compatible with T-BERD/MTS-2000, -4000, -4000 V2 and -5800 platforms |
Benefits |
The most compact CWDM OTDR solution in the market: 18 CWDM wavelengths covered in only 2 OTDR modules |
Perfect for end-to-end link characterization during network deployment/ construction |
Ideal to test new CWDM wavelength routes or pinpoint faults and know their exact locations without disrupting traffic on active channels |
Can be combined with a CWDM spectrum analyzer module (COSA-4055) to measure the wavelengths and power levels of active CWDM channels |
Applications |
Characterize end-to-end links with exact CWDM wavelengths |
Troubleshoot active networks with in-service testing capability |
Verify end-to-end continuity with the continuous wave source function |
Specifications | |
4100-Series CWDM OTDR Modules | |
General Technical (typical at 25°C) | |
Laser Safety | Class 1 (IEC), Class 1 (21CFR) |
Weight | 430g (0.95 lb) |
Dimensions (W x H x D) | 128 x 134 x 40 mm (5 x 5.28 x 1.58 in) |
Distance Units | Km/m/mile/ft |
Group Index Range | 1.30000 to 1.70000 in 0.00001 steps |
Number of Data Points | Up to 256,000 data points |
Distance Measurements Mode Display Range Display Resolution Cursor Resolution Sampling Resolution Accuracy | Automatic or dual cursor From 0.5 up to 260 km 1 cm From 1 cm From 4 cm ±1 m ±sampling resolution ±1.10-5 x distance (excluding group index uncertainties) |
Attenuation Measurements Mode Display Range Display Resolution Cursor Resolution Attenuation Linearity Threshold | Automatic, manual, 2-point, 5-point and LSA From 1.25 dB to 55 dB 0.001 dB From 0.001 dB ±0.03 dB/dB 0.01 to 1.99 dB in 0.01 dB step |
Reflectance/ORL Measurements Mode Reflectance Accuracy Display resolution Threshold Storage | Automatic or manual ±2 dB 0.01 dB –11 to –98 dB in 1 dB steps Bellcore/Telcordia compatible Version 1.1 and Version 2.0 |
Specifications | |
4100-Series CWDM OTDR Modules | |
General Technical (typical at 25°C) | |
OTDR | |
CWDM Wavelengths(1) | 1271/1291/1311/1331/1351/1371/1391/ 1411/1431/1451/1471/1491/1511/1531/ 1551/1571/1591/1611nm +/-3nm |
Pulsewidth | 10 ns to 20 μs |
Dynamic range(2) | 35dB |
Event dead zone(3) | 1.5 m |
Attenuation dead zone(4) | 5 m |
Continuous Wave Light Source | Wavelengths: same as OTDR Output power -3.5 dBm Operating modes(5): CW, 270 Hz, 330 Hz, 1 kHz, 2 kHz |
Automatic traffic detection | Yes |
In-service testing | Yes |
Notes:
(1) Laser at 25°C and measured at 10 µs.
(2) The one-way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging and using the largest pulsewidth.
(3) Measured at ±1.5 dB down from the peak of an unsaturated reflective event using the shortest pulsewidth.
(4) Measured at ±0.5 dB from the linear regression using a FC/PC reflectance and using the shortest pulsewidth.
(5) Subtract 3 dB when used in modulation mode (270/330/1/2 kHz).
Specifications | |
Ordering Information | |
Part Number | Description |
4100 CWDM OTDR Modules | |
E41CWDM10L | 1271 to 1451 nm |
E41CWDM8U | 1471 to 1611 nm |
E41CWDM10U | 1431 to 1611 nm |
Optical Connectors | |
EUSCADS, EUFCADS, EULCADS | Screw type adapter for PC connectors |
EUSCADS-APC, EUFCADS, EULCADS-APC | Screw type adapter for APC (8°) connectors |