RF & Microwave Spectrum AnalyzersSpectrum Analyzers-Economy85GHz <50GHz <= 85GHz特性 | 参数 |
---|---|
High Frequency (range) | 85GHz < |
Low Frequency (range) | 50GHz <= 85GHz |
The N9042B Signal Analyzer sets a new level of performance for high frequency measurements. Frequency options up to 50 GHz cover the current 5GNR FR1 and FR2 bands, as well as most radar, EW, and satellite bands. Analysis bandwidth can be configured to 1 GHz; 1.5 GHz, 2 GHz, 4 GHz; and even up to 11 GHz bandwidth using an external digitizer. A completely new front end provides low noise performance and high-dynamic range, addressing applications in Tx test, such as EVM and other modulation quality tests – while also excelling at measurements of low-level and unknown signals.
The V3050A Frequency Extender can be combined with the N9042B, to extend the maximum frequency up to 110 GHz. The V3050A features a low-noise design for outstanding sensitivity; a preselector filterbank to eliminate image responses; fundamental mixing for high dynamic range; and a “remote head” form-factor that interfaces seamlessly to the N9042B. The N9042B supports the X-series family of multi-touch applications, as well as the 89600 VSA software. A new CPU performs compute-intensive measurements, such as demodulation and EVM, up to 40% faster than prior analyzers.
Specifications | |
N9042B UXA X-Series Signal Analyzer | |
Model / Option Number | Description |
Frequency Range | |
N9042B-526 | Frequency range, 2 Hz to 26.5 GHz |
N9042B-544 | Frequency range, 2 Hz to 44 GHz |
N9042B-550 | Frequency range, 2 Hz to 50 GHz |
V3050A Frequency Extender Option | |
Option | Frequency Range |
F06 | 50 GHz to 67 GHz |
F09 | 50 GHz to 90 GHz* |
F11 | 50 GHz to 110 GHz** |
Notes:
* Opt ion F09 conforms to limit ations governing export to restricted countries (does not require IVL ). When used for w ide-bandwidth analysis (IQ), the highest allowed frequency (at center of bandwidth) is reduced by ½ of the maximum bandw idth that is configured (optional licenses) for a given instrument. For example, with option R20 licensed (2 GHz analy sis bandwidth), the maximum center frequency allowed is 89 GHz.
** I VL required for export to restricted countries
Specifications | |
V3050A Frequency Extender Option | |
Features | Parameters |
LO Input Level | >=0 dBm (nom), to achieve nom. conversion loss and cal accuracy (not user controllable) (-10 dBm leads to changes of 1 to 2.5 dB in conversion loss) (nom) +18 dBm max (damage level) |
Preselector Type | 5-band, electronically switched, band-pass filter |
Image Rejection | >60 dB (nom), 50 to 88 GHz >30 dB (nom), 88 to 110 GHz; supplemented with software pre-selection |
Spurious Responses | <-80 dBm (nom), for input signals at –20 dBm, anywhere in 50 to 110 GHz |
Input Connector | 1.0mm (m), ruggedized |
Input Match (nom) | <-10 dB return loss (1.9 VSWR), at 50 to 90 GHz, Attenuation 10 dB <-5 dB return loss (3.5 VSWR), at 90 to 110 GHz, Attenuation 10 dB |
Rear Connectors (listed top to bottom) | LO Out: 2.4mm (f) (reserved for future use) LO In: 2.4mm (f) IF Out: 3.5mm (f) Pass Thru <50 GHz: 1.85mm (f) (can be mated with 2.4mm) |
USB Connector | USB C PD: USB Type-C with Power Delivery (requires 15V, 1.75A, 27 W minimum) |
IF Frequency Out | 7.5225 GHz (in swept) |
Data Storage | Factory cal data stored in non-volatile memory, read by N9042B (not user-accessible) |
Dimensions: | Length: 93 mm (3.66in), without connectors; 128 mm (5.04in), with connector Height: 81 mm (3.19 in) Width (Thickness): 36 mm (1.42 in) |
Weight | 0.42 kg (0.19 lbs) |
Mounting Points | 4 ea threaded holes for M3 x 0.5 |
Accessories Included | Adapter, 1.0mm to 1.0 mm (connector saver) with Opt F09 and F11 Adapter, 1.0mm to 1.85mm with Opt F06 Adapter locking collar (V3050-60006) Adapter, 2.4mm (33311-82005) (for Pass-Thru at N9042B Input) Torque wrench, 14mm, torque 10 in-lb and 4 in-lb Interface cable bundle, 4 cables, ~1 meter long (V3050-60004) Base plate (press fit, weighted for stabilization) (V3050-60005) |
Environmental and Certifications | |
Temperature Range | Operating: 20 to 30 °C Storage: 20 to 30 °C |
Cooling | Active forced-air fan cooling; must maintain 5 cm (2 in) of clearance around faces of V3050A with vents |
Specifications | ||
V3050A | ||
Model Overview | ||
Model / Option Number | Description | Additional Information |
V3050A | Signal analyzer frequency extender | Requires N9042B-EXW; Extends frequency from 50 GHz to 67, 90 or 110 GHz |