配置型号包含以下特性:
RF & Microwave PowerNoise & OtherNoise Figure Meters请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
The CNG-EbNo is a fully automated instrument that sets and maintains a highly accurate ratio between a user-supplied carrier and internally generated AWGN noise, over a wide range of signal power levels and frequencies.
The CNG-EbNo gives system, design, and test engineers in the cellular/PCS, satellite and military communication industries a cost-effective means of obtaining higher yield through automated testing, plus increased confidence from repeatable, accurate test results.
Key Features |
C/N carrier to noise ratio |
C/I carrier to interferer ration |
C/No carrier to noise density ratio |
Eb/No bit energy to noise density ratio |
Custom configurations |
6.25" color TFT touch screen |
Accuracy of 0.2 dB RSS |
Bit Rates from 1 bps to 1 Gbs |
Variable Output Power from -55 dBm to +5 dBm |
Benefits | |
Multiple Operating Modes | The CNG-EbNo provides five operating modes: carrier-to-noise (C/N), carrier-to-noise density (C/N₀ ), bit energy-to-noise density (Eb/N₀ ), carrier-to-interferer (C/I), and power meter. The instrument can also be used as a precision noise generator. |
Custom Configurations | The CNG-EbNo is available in a variety of configurations to meet your specific testing needs. Applications include: military communications WCDMA SATCOM NASA TDRSS CableTV HDTV IS-95 CDMA TSMA UMTS GPRS L-band modems Milstar Inmarsat Intelsat General Purpose. |
Direct Display of Eb/No, C/N, C/I, or C/No | The 6.25” color TFT touch screen provides simultaneous readout of all significant input and output signal levels relating to the chosen operating mode, including carrier-to-noise ratios. |
Accuracy of 0.2 dB RSS | A special, large-dynamic-range power meter measures both the signal and the noise, which allows the CNG-EbNo to set the desired ration to within ±0.2 dB. Special configurations can provide improved accuracy. |
Bit Rate Entry of 1 bps to 999 Mbps and above | In bit energy-to-noise density testing (Eb/No ), the instrument automatically calculates noise density based on the user specified bit rate. |
Variable Output Power | Output power is user-specified and can be set within the range of -55 dBm to +5 dBm. |
True RMS Power Meter | The digital power meter is custom designed to cover the frequency range of the particular instrument. It can measure signals and noise accurately with Gaussian Noise crest factors up to 18 db. |
Direct Testing at both RF and Microwave Frequencies | In configurations that cover two separate frequency ranges, measurements can be made directly without the need for special conversion circuitry. |
Specifications | |
CNG-EbNo Precision SNR Noise Generator | |
Feature | Parameter |
Carrier Path | Input Power Range: -55 dBm to +5 dBm Maximum Input Power: +21 dBm (with no damage) Output Power Range: -55 dBm to +5 dBm |
Noise Path | Output Power Range: -55 dBm to +5 dBm Ratio Accuracy: ±0.2 dB RSS, ±0.3 dB WCU Power Meter Range: -55 dBm to +5 dBm Power Meter Accuracy: ±0.5 dB |
Primary Power | Operating Temperature: 0° to 50° C Dimensions: 17” W x 5.25” H x 17.5” D |
Specifications | |
CNG-EbNo Precision SNR Noise Generator | |
Model Overview | |
Model | Frequency Range |
CNG-EbNo-70 | 50 to 90 MHz |
CNG-EbNo-IF1 | 50 to 90 MHz 100 to 180 MHz |
CNG-EbNo-105 | 65 to 75 MHz 50 to 90 MHz 100 to 180 MHz 10 to 200 MHz |
CNG-EbNo-225 | 50 to 400 MHz |
CNG-EbNo-750 | 650 to 850 MHz |
CNG-EbNo-1550 | 950 to 1200 MHz 1150 to 1450 MHz 1400 to 1700 MHz 1650 to 1950 MHz 1900 to 2150 MHz |
CNG-EbNo-1550A | 950 to 2150 MHz |
CNG-EbNo-1700 | 1400-2000 MHz 1610-1790 MHz 1680-1720 MHz |
CNG-EbNo-2105 | 1710 to 2500 MHz |
CNG-EbNo-2450 | 2200 to 2700 MHz |
CNG-EbNo-4600 | 3400 to 5800 MHz |
CNG-EbNo-20000 | 18 to 22 GHz |