配置型号包含以下特性:
RF & Microwave PowerNoise & OtherMicrowave Accessories请参考资源中的资料文档或查看产品总览。
如果您想了解更多,请 联系,我们的团队将为您提供帮助。
The Keysight 11970A waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.
The 11970A extends the frequency range of the Keysight N9030A PXA high-performance signal analyzer to the A-Band (26.5 to 40 GHz). It is also fully compatible with other Keysight spectrum analyzers including: the E4440A/46A/48A PSA (with Option AYZ), the E4407B ESA-E (with Option AYZ), the 856xEC, the 8566B (with a preamplifier), and the 7000 modular analyzer (with the 70907A/B external mixer interface module).
An external diplexer is required to connect the 11970A with the N9030A PXA (with Option EXM). The recommended diplexer can be purchased from Keysight as model number N9029AE13 or from OML, Inc as model number DLP.313B.
Key Features |
Flat frequency response |
Low conversion loss |
No bias or tuning adjustments |
100 mW safe input level |
Specifications | |
11970 Series Harmonic Mixers | |
Series Overview | |
Model | Frequency |
11970K* | 18 to 26.5 GHz |
11970A | 26.5 to 40 GHz |
11970Q | 33 to 50 GHz |
11970U | 40 to 60 GHz |
11970V | 50 to 75 GHz |
11970W | 75 to 110 GHz |
Note:
* 11970K is excluded from PXA support
Specifications | |||||
Waveguide Harmonic Mixer | |||||
Series Overview | |||||
Model Number | 11970A | 11970Q | 11970U | 11970V | 11970W |
IF Range | DC to 1300 MHz | DC to 1300 MHz | DC to 1300 MHz | DC to 1300 MHz | DC to 1300 MHz |
LO Amplitude Range | +14 to +18 dBm* | +14 to +18 dBm* | +14 to +18 dBm* | +14 to +18 dBm* | +14 to +18 dBm* |
Calibration Accuracy (with IF of 321.4 MHz or 322.5 MHz) | ±2.0 dB with LO amplitude range of +14.5 to +16 dBm ±3.0 dB with LO amplitude range of +16 to +18 dBm | ±2.0 dB with LO amplitude range of +14.5 to +16 dBm ±3.0 dB with LO amplitude range of +16 to +18 dBm | ±2.0 dB with LO amplitude range of +14.5 to +16 dBm ±3.0 dB with LO amplitude range of +16 to +18 dBm | ±2.6 dB with LO amplitude range of +14.5 to +16 dBm ±3.2 dB with LO amplitude range of +16 to +18 dBm | ±2.6 dB with LO amplitude range of +14.5 to +16 dBm ±3.2 dB with LO amplitude range of +16 to +18 dBm |
Nominal RF Input SWR | < 2.2:1 | < 2.2:1 | < 2.2:1 | < 2.6:1 | < 2.6:1 |
Bias Requirements | None | None | None | None | None |
Nominal Odd-Order Suppression | > 20 dB | > 20 dB | > 20 dB | > 15 dB | > 15 dB |
Maximum CW RF Input Level | +20 dBm (100 mW) | +20 dBm (100 mW) | +20 dBm (100 mW) | +20 dBm (100 mW) | +20 dBm (100 mW) |
Maximum Peak Pulse Power | +24 dBm (250 mW) with < 1 μs pulse (average power +20 dBm) | +24 dBm (250 mW) with < 1 μs pulse (average power +20 dBm) | +24 dBm (250 mW) with < 1 μs pulse (average power +20 dBm) | +24 dBm (250 mW) with < 1 μs pulse (average power +20 dBm) | +24 dBm (250 mW) with < 1 μs pulse (average power +20 dBm) |
Note:
* An LO power of between 14.5 to 16 dBm at the mixer’s LO input is necessary to achieve the given frequency response and spectrum analyzer amplitude accuracy specifications. When LO power varies between 14 to 18 dBm at the mixer’s LO input, add ±1 dB to the frequency response and spectrum analyzer amplitude accuracy specification.